Patrick Nadoll

Patrick Nadoll

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2014 in Ore Geology Reviews
Verified
Journal Article
Closed access
PNPatrick Nadoll
Patrick Nadoll
TAThomas Angerer
Thomas Angerer
JMJeffrey L. Mauk
Jeffrey L. Mauk
DFDavid French
David French
JWJohn Walshe
John Walshe

1 September 2012 in Economic Geology
Verified
Journal Article
Closed access
PNPatrick Nadoll
Patrick Nadoll
JMJ. L. Mauk
J. L. Mauk
THT. S. Hayes
T. S. Hayes
AKA. E. Koenig
A. E. Koenig
SBS. E. Box
S. E. Box

23 August 2014 in Mineralium Deposita
Verified
Journal Article
Closed access
PDF file
PNPatrick Nadoll
Patrick Nadoll
JMJeffrey L. Mauk
Jeffrey L. Mauk
RLRichard A. Leveille
Richard A. Leveille
AKAlan E. Koenig
Alan E. Koenig

16 June 2011 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
PNPatrick Nadoll
Patrick Nadoll
AKAlan E. Koenig
Alan E. Koenig
Magnetite (Fe3O4) is a common accessory mineral in many geologic settings. Its variable geochemistry makes it a powerful petrogenetic indicator. Electron microprobe (EMPA) analyses are commonly used to examine major and minor element contents in magnetite. Laser ablation ICP-MS (LA-ICP-MS) is applicable to trace element analyses of magnetite but has not been widely employed to examine compositional variations. We tested the applicability of the NIST SRM 610, the USGS GSE-1G, and the NIST SRM 2782 reference materials (RMs) as external standards and developed a reliable method for LA-ICP-MS analysis of magnetite. LA-ICP-MS analyses were carried out on well characterized magnetite samples with a 193 nm, Excimer, ArF LA system. Although matrix-matched RMs are sometimes important for calibration and normalization of LA-ICP-MS data, we demonstrate that glass RMs can produce accurate results for LA-ICP-MS analyses of magnetite. Cross-comparison between the NIST SRM 610 and USGS GSE-1G indicates good agreement for magnetite minor and trace element data calibrated with either of these RMs. Many elements show a sufficiently good match between the LA-ICP-MS and the EMPA data; for example, Ti and V show a close to linear relationship with correlation coefficients, R2 of 0.79 and 0.85 respectively.

20 March 2014 in Journal of Metamorphic Geology
Verified
Journal Article
Closed access
PDF file
AWA. J. R. White
A. J. R. White
MLM. Legras
M. Legras
RSR. E. Smith
R. E. Smith
PNPatrick Nadoll
Patrick Nadoll

12 April 2014 in Journal of Petrology
Verified
Journal Article
Closed access
AWAlistair J. R. White
Alistair J. R. White
RSRaymond E. Smith
Raymond E. Smith
PNPatrick Nadoll
Patrick Nadoll
MLMonica Legras
Monica Legras