Wonyong Chung

Dr. Wonyong Chung

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2025 in EPJ Web of Conferences
Verified
Journal Article
Open access
WCWonyong Chung
Wonyong Chung
A differentiable full detector simulation has been implemented in the key4hep software stack for future colliders. A fully automated and configurable geometry enabling differentiation of all detector dimensions, including crystal widths and thicknesses, is presented. The software architecture, development environment, and necessary components to implement a new detector concept from scratch are described. General AI/ML reconstruction strategies for future collider detectors are discussed, based around the idea of picking the right neural network for each detector.

2 September 2025 in Universe
Verified
Journal Article
Open access
PDF file
WCWonyong Chung
Wonyong Chung
MFMark Farino
Mark Farino
ATAndi Tan
Andi Tan
CTChristopher George TULLY
Christopher George TULLY
SZShiran Zhang
Shiran Zhang
The search for keV-scale sterile neutrinos in tritium beta decay is made possible through the theoretically allowed small admixture of electron flavor in right-handed, singlet, massive neutrino states. A distinctive feature of keV-scale sterile-neutrino–induced threshold distortions in the tritium beta spectrum is the presence of quantized nuclear-recoil effects, as predicted for atomic tritium bound to two-dimension materials such as graphene. The sensitivities to the sterile neutrino mass and electron-flavor mixing are considered in the context of the PTOLEMY detector simulation with tritiated graphene substrates. The ability to scan the entire tritium energy spectrum with a narrow energy window, low backgrounds, and high-resolution differential energy measurements provides the opportunity to pinpoint the quantized nuclear-recoil effects. providing an additional tool for identifying the kinematics of the production of sterile neutrinos. Background suppression is achieved by transversely accelerating electrons into a high magnetic field, where semi-relativistic electron tagging can be performed with cyclotron resonance emission RF antennas followed by deceleration through the PTOLEMY filter into a high-resolution differential energy detector operating in a zero-magnetic-field region. The PTOLEMY-based approach to keV-scale searches for sterile neutrinos involves a novel precision apparatus utilizing two-dimensional materials to yield high-resolution, sub-eV mass determination for electron-flavor mixing fractions of |Ue4|2≃10−5 and smaller.

24 January 2022 in arXiv
Verified
Preprint
Open access
PDF file
AAA. Apponi
A. Apponi
MBM. G. Betti
M. G. Betti
MBM. Borghesi
M. Borghesi
ABA. Boscá
A. Boscá
FCF. Calle
F. Calle
FZF. Zhao
F. Zhao
The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to <10 eV (<1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratary (LNGS) in Italy.

8 May 2025 in arXiv
Verified
Preprint
Open access
PDF file
WCWonyong Chung
Wonyong Chung
Reconstructing low-dimensional truth labels from high-dimensional experimental data is a central challenge in any scenario that relies on robust mappings across this so-called domain gap, from multi-particle final states in high-energy physics to large-scale early-universe structure in cosmological surveys. We introduce a new method to bridge this domain gap with an intermediate, synthetic representation of truth that differs from methods operating purely in latent space, such as normalizing flows or invertible approaches, in that the synthetic data is specifically engineered to represent intrinsic detector hardware capabilities of the system at hand. The hypothesis is that by encoding physical properties of the detector response available only in full simulation, such synthetic representations result in a less lossy compression and recovery than a direct mapping from truth to experimental data. We demonstrate a first implementation of this concept with full simulation of a dual-readout crystal electromagnetic calorimeter for future collider detectors, in which the synthetic data is constructed to be the simulated detector hits corresponding to photon tracks of scintillation and Cerenkov photons. We refer to these signals as simulated observables as they would not be physical observables in a real detector, but are nonetheless representations of a real physical process. First results show that the synthetic representation naturally anchors the neural network architecture to a known physical method, in this case the dual-readout correction. We believe this strategy opens new avenues for machinistic interpretability and explainability of ML-based reconstruction methods. In the case of anomalous signal detection, we hypothesize that anomalous signals detected in networks trained on synthetic data rooted in a physical process are more likely to be indicative of a genuinely physical anomaly.

9 September 2026 in Physical Review Applied
Verified
Journal Article
Open access
RARoberto Ammendola
Roberto Ammendola
AAA. Apponi
A. Apponi
GBG. Benato
G. Benato
MBMaria Grazia Betti
Maria Grazia Betti
RBRiccardo Biondi
Riccardo Biondi
MVM. Viviani
M. Viviani
We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100-eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of ( 60 × 60 ) μ m 2 and a critical temperature of approximately 80 mK . The electron source is based on vertically aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the ( 92 – 99 ) eV kinetic energy range, we obtain a Gaussian energy resolution for fully absorbed electrons of ( 0.48 ± 0.04 ± 0.06 ) eV , where the first uncertainty is statistical and the second systematic. When considering the full-width at half-maximum of the peak of the signal amplitude distribution, the corresponding resolution is of ( 1.4 ± 0.2 ± 0.3 ) eV . The former represents an improvement of ( 47 – 60 ) % with respect to previous results and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 21 and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.