Pietro Arcuri

Dr. Pietro Arcuri

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Journal of Rehabilitation Medicine
Verified
Journal Article
Closed access
LBLuigia Brugliera
Luigia Brugliera
ASAlfio Spina
Alfio Spina
PCP Castellazzi
P Castellazzi
PCP Cimino
P Cimino
ATAndrea Tettamanti
Andrea Tettamanti
SIS Iannaccone
S Iannaccone

20 May 2020 in European Journal of Clinical Nutrition
Verified
Journal Article
Open access
PDF file
LBLuigia Brugliera
Luigia Brugliera
ASAlfio Spina
Alfio Spina
PCPaola Castellazzi
Paola Castellazzi
PCPaolo Cimino
Paolo Cimino
PAPietro Arcuri
Pietro Arcuri
SISandro Iannaccone
Sandro Iannaccone

20 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
GBGaia Bailo
Gaia Bailo
FSFrancesca Lea Saibene
Francesca Lea Saibene
VBVirginia Bandini
Virginia Bandini
PAPietro Arcuri
Pietro Arcuri
ASAnna Salvatore
Anna Salvatore
ICIlaria Carpinella
Ilaria Carpinella
Although the 6-Minute Walk Test (6MWT) is among the recommended clinical tools to assess gait impairments in individuals with Parkinson’s disease (PD), its standard clinical outcome consists only of the distance walked in 6 min. Integrating a single Inertial Measurement Unit (IMU) could provide additional quantitative and objective information about gait quality complementing standard clinical outcome. This study aims to evaluate the test–retest reliability, validity and discriminant ability of gait parameters obtained by a single IMU during the 6MWT in subjects with mild PD. Twenty-two people with mild PD and ten healthy persons performed the 6MWT wearing an IMU placed on the lower trunk. Features belonging to rhythm and pace, variability, regularity, jerkiness, intensity, dynamic instability and symmetry domains were computed. Test–retest reliability was evaluated through the Intraclass Correlation Coefficient (ICC), while concurrent validity was determined by Spearman’s coefficient. Mann–Whitney U test and the Area Under the receiver operating characteristic Curve (AUC) were then applied to assess the discriminant ability of reliable and valid parameters. Results showed an overall high reliability (ICC ≥ 0.75) and multiple significant correlations with clinical scales in all domains. Several features exhibited significant alterations compared to healthy controls. Our findings suggested that the 6MWT instrumented with a single IMU can provide reliable and valid information about gait features in individuals with PD. This offers objective details about gait quality and the possibility of being integrated into clinical evaluations to better define walking rehabilitation strategies in a quick and easy way.

ACAntonio Caronni
Antonio Caronni
MRMarina Ramella
Marina Ramella
PAPietro Arcuri
Pietro Arcuri
CSClaudia Salatino
Claudia Salatino
LPLucia Pigini
Lucia Pigini
RCRosa Maria Converti
Rosa Maria Converti
This study aims to test the construct validity and reliability of the Quebec User Evaluation of Satisfaction with assistive Technology 2.0 (QUEST)–device, an eight-item questionnaire for measuring satisfaction with assistive devices. We collected 250 questionnaires from 79 patients and 32 caregivers. One QUEST was completed for each assistive device. Five assistive device types were included. QUEST was tested with the Rasch analysis (Many-Facet Rating Scale Model: persons, items, and device type). Most patients were affected by neurological disabilities, and most questionnaires were about mobility devices. All items fitted the Rasch model (InfitMS range: 0.88–1.1; OutfitMS: 0.84–1.28). However, the ceiling effect of the questionnaire was large (15/111 participants totalled the maximum score), its targeting poor (respondents mean measure: 1.90 logits), and its reliability was 0.71. The device classes had different calibrations (range: −1.18 to 1.26 logits), and item 3 functioned differently in patients and caregivers. QUEST satisfaction measures have low reliability and weak construct validity. Lacking invariance, the QUEST total score is unsuitable for comparing the satisfaction levels of users of different device types. The differential item functioning suggests that the QUEST could also be problematic for comparing satisfaction in patients and caregivers.

2 July 2023 in Entropy
Verified
Journal Article
Open access
PDF file
JMJuan Ruiz de Miras
Juan Ruiz de Miras
CDChiara-Camilla Derchi
Chiara-Camilla Derchi
TATiziana Atzori
Tiziana Atzori
AMAlice Mazza
Alice Mazza
PAPietro Arcuri
Pietro Arcuri
ACAngela Comanducci
Angela Comanducci
Complexity analysis of electroencephalogram (EEG) signals has emerged as a valuable tool for characterizing Parkinson’s disease (PD). Fractal dimension (FD) is a widely employed method for measuring the complexity of shapes with many applications in neurodegenerative disorders. Nevertheless, very little is known on the fractal characteristics of EEG in PD measured by FD. In this study we performed a spatio-temporal analysis of EEG in PD using FD in four dimensions (4DFD). We analyzed 42 resting-state EEG recordings comprising two groups: 27 PD patients without dementia and 15 healthy control subjects (HC). From the original resting-state EEG we derived the cortical activations defined by a source reconstruction at each time sample, generating point clouds in three dimensions. Then, a sliding window of one second (the fourth dimension) was used to compute the value of 4DFD by means of the box-counting algorithm. Our results showed a significantly higher value of 4DFD in the PD group (p < 0.001). Moreover, as a diagnostic classifier of PD, 4DFD obtained an area under curve value of 0.97 for a receiver operating characteristic curve analysis. These results suggest that 4DFD could be a promising method for characterizing the specific changes in the brain dynamics associated with PD.

Verified
Journal Article
Open access
PDF file
FPFederica Piancone
Federica Piancone
Francesca La RosaFrancesca La Rosa
Francesca La Rosa
AHAmbra Hernis
Ambra Hernis
IMIvana Marventano
Ivana Marventano
PAPietro Arcuri
Pietro Arcuri
ACAngela Comanducci
Angela Comanducci
Traumatic brain injury (TBI), a leading cause of mortality and disability, recognizes a primary, immediate injury due to external forces, and a secondary phase that includes inflammation that can lead to complications such as the post-traumatic confusional state (PTCS), potentially impacting long-term neurological recovery. An earlier identification of these complications, including PTCS, upon admission to intensive rehabilitation units (IRU) could possibly allow the design of personalized rehabilitation protocols in the immediate post-acute phase of moderate-to-severe TBI. The present study aims to identify potential biomarkers to distinguish between TBI patients with and without PTCS. We analyzed cellular and molecular mechanisms involved in neuroinflammation (IL-6, IL-1β, IL-10 cytokines), neuroendocrine function (norepinephrine, NE, epinephrine, E, dopamine), and neurogenesis (glial cell line-derived neurotrophic factor, GDNF, insuline-like growth factor 1, IGF-1, nerve growth factor, NGF, brain-derived growth factor, BDNF) using enzyme-linked immunosorbent assay (ELISA), comparing results between 29 TBI patients (17 with PTCS and 12 non-confused) and 34 healthy controls (HC), and correlating results with an actigraphy-derived sleep efficiency parameter. In TBI patients compared to HC, serum concentration of (1) pro-inflammatory IL-1β cytokine was significantly increased while that of anti-inflammatory IL-10 cytokine was significantly decreased; (2) NE, E and DA were significantly increased; (3) GDNF, NGF and IGF-1 were significantly increased while that of BDNF was significantly decreased. Importantly, IL-10 serum concentration was significantly lower in PTCS than in non-confused patients, correlating positively with an improved actigraphy-derived sleep efficiency parameter. An anti-inflammatory environment may be associated with better prognosis after TBI.