Jinia Roy

Dr. Jinia Roy


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JRJinia Roy
Jinia Roy
YXYinglai Xia
Yinglai Xia
RARajapandian Ayyanar
Rajapandian Ayyanar
This paper explores a power conversion system for single phase transfomer-less AC module application. A nonisolated high gain dc-dc stage is coupled with a doubly-grounded dynamic dc-link inverter to implement the microinverter topology. The front-end boost stage steps up the single module voltage to a higher dc voltage, typically to 200V or 400V as required for the following inverter stage. It is a hybrid of an interleaved boost and switched capacitor concept capable of achieving high gain while simultaneously maintaining reduced voltage and current stress and thus lower switching and conduction loss for most of the switches. By directly connecting the grid-neutral to the PV negative, the doubly-grounded voltage-swing inverter has the advantage of zero capacitive-coupled common-mode ground currents, critical for transformer-less PV inverters. The two dc-links of the inverter stage share the double line frequency power decoupling with a combination of higher value of mean voltage and relatively large 120Hz ripple component - the dynamic dc-link approach. Through an optimization algorithm, the decoupling capacitance is minimized enabling an all-film capacitor implementation while satisfying the converter's operating constraints over a wide range of power-factor. The simulation as well as experimental results from a GaN based hardware-prototype validate the converter's performance.

26 November 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
YXYinglai Xia
Yinglai Xia
JRJinia Roy
Jinia Roy
RARajapandian Ayyanar
Rajapandian Ayyanar
Reducing the power loss of a converter without increasing its volume or cost in hardware has always been a much sought-after but challenging goal. This article proposes a comprehensive variable switching frequency (VSF) scheme to improve the overall system efficiency while still meeting a given total harmonic distortion (THD) requirement without any hardware changes, achieved only by changes to the controller. In this article, it is analyzed that for the H-bridge inverter, the inductor copper loss and the switch conduction loss are independent of the switching frequency (SF), while the device switching loss and the inductor core loss are functions of the SF. This article aims at weighting the combined switching loss and inductor core loss for both the unipolar and bipolar modulation techniques, with the constraint on the output THD, which, for fixed passive components, is a function of inductor ripple current that in turn depends on the SF. An optimal VSF scheme is devised through rigorous mathematical analysis of the output ripple component and the SF-dependent losses. In each switching cycle, the inductor ripple current is predicted with the circuit parameters, such as duty cycle, switching period, inductance, and dc voltage, and by implementing the VSF scheme, the current ripple is optimally varied such as to satisfy the THD requirement while reducing the SF-dependent losses. A generalized method to design VSF schemes for any topology and specifications is also presented, which would help future users in designing the VSF controller. A 1-kW H-bridge inverter using SiC MOSFETs and powdered iron/ferrite core has been built to validate the theoretical analysis. Both constant SF (CSF) scheme (200 kHz) and optimal VSF scheme with simple controller modification have been implemented in the experimental prototype using DSP TMS320f28335. Compared with the CSF scheme, the optimal VSF scheme shows a significant improvement in the system efficiency at rated power from 94.7% to 95.4% with a corresponding saving of 16.5% in the SF-dependent loss in unipolar modulation and from 95.5% to 96.8% with a corresponding saving of 36.5% in the SF-dependent loss in bipolar modulation.

24 October 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JRJinia Roy
Jinia Roy
YXYinglai Xia
Yinglai Xia
RARajapandian Ayyanar
Rajapandian Ayyanar
Photovoltaic (PV) inverters form the backbone of PV generation. This paper proposes an all-film-capacitor, transformerless single-phase inverter for PV application. The topology is a combination of a front-end boost stage, a half-bridge (HB) inverter stage, and a buck-boost power decoupling stage. The grid ripple power is decoupled by a large swing of the HB capacitors along with a limited ripple on the dc link, thus reducing the capacitance requirement and converter volume. Being an HB-derived inverter, the high-frequency common mode leakage current through the PV parasitic capacitance is mitigated. Furthermore, the dc-link average is optimally controlled to ensure a higher efficiency over wide operating load and power factor range. To validate its operation, a Silicon Carbide based 1-kVA laboratory prototype is built and closed-loop experimental results are provided at 100/75 kHz switching frequency over wide operating conditions.

6 May 2021 in IEEE Open Journal of the Industrial Electronics Society
Verified
Journal Article
Open access
JRJinia Roy
Jinia Roy
AGAnkul Gupta
Ankul Gupta
RARajapandian Ayyanar
Rajapandian Ayyanar
A typical non-isolated photovoltaic (PV) microinverter requires a high conversion ratio in the dc-dc stage as well as needs to support a wide range of input-output voltage operation accommodating partial shading scenario. An extended-duty-ratio (EDR) boost converter is a good candidate for such application as it provides a high efficiency solution with a hybrid of interleaved inductor and switched capacitor configuration significantly lowering the switch voltage stress, switching losses, and providing inherent equal current sharing among the input phases. However, these advantages of EDR boost converter in continuous conduction mode (CCM) is only true for a limited duty ratio range. On the contrary, it is observed that the discontinuous conduction mode (DCM) can support a wider range of duty ratio operation, maintaining lower voltage stress on the devices and ensuring inherent equal current sharing among the boost inductors. Nevertheless, even in the DCM, the operation in the region with least voltage gain becomes very complex and requires a thorough understanding. This paper presents an extensive analysis of an EDR boost converter for DCM operation for all the operating regions. The operating characteristics of an EDR boost converter in DCM is analysed and its gain is derived. The detailed analysis presented in this paper enables in designing the components and judiciously deciding the operating range of EDR boost converter in DCM operation for any application. In order to verify the analysis, the simulation and experimental results from a 300 W EDR boost hardware prototype are also provided.

20 July 2020 in IEEE Open Journal of Power Electronics
Verified
Journal Article
Open access
YXYinglai Xia
Yinglai Xia
JRJinia Roy
Jinia Roy
RARaja Ayyanar
Raja Ayyanar
In this paper, a T-type common ground transformerless single phase inverter with dynamic swing of the dc-link voltage is presented for photovoltaic (PV) application. The topology is a combination of a bi-directional, partial-power processing boost stage and an asymmetric half-bridge inverter stage along with a T-branch. It takes advantage of the three-level switching states with reduced voltage stress on the main switches to achieve lower switching loss. The double line frequency power decoupling is addressed by a dynamic dclink approach, which allows a large swing of the dc-link to reduce the decoupling capacitor requirement. This topology also significantly reduces the high-frequency capacitive coupled ground current by directly connecting the PV negative terminal to the grid neutral. Moreover, an adaptive dc-link voltage control scheme that optimally changes the average value of the dc-link voltage as the operating conditions vary, has been proposed and thoroughly investigated. A SiC MOSFETs-based 1 kVA laboratory prototype has been built to validate the converter's operation at 200 V dc nominal input and 120 V/60 Hz ac nominal output. Extensive experimental results validate the superior performance of the topology showing a peak efficiency of 98.22% and a CEC efficiency of 98.03% at 50 kHz switching frequency.

1 September 2016
Verified
Conference Paper
Closed access
YXYinglai Xia
Yinglai Xia
JRJinia Roy
Jinia Roy
RARaja Ayyanar
Raja Ayyanar
Transformer-less PV inverters are gaining widespread applications with lower cost, reduced footprint, and improved efficiency. This paper proposes a topology that can eliminate the common mode leakage current which is a major challenge in transformer-less PV inverters. In addition, an active power decoupling strategy is implemented in this topology instead of using large energy storage element for double line frequency power decoupling, thus achieving a smaller volume. A constant input voltage with negligible double line frequency ripple component ensuring high MPPT efficiency is achieved in this topology. Compared to the previously proposed topology, a T-type branch is added as an improvement to fully take advantage of the inherent three level structure resulting in much reduced switching loss and inductor current ripple. A 1 kW, 100 kHz single-phase prototype with 200 V DC input and 120 V/60 Hz AC output using SiC MOSFETs has been built to validate the theoretical analysis. The control strategy and modulation scheme are implemented in DSP TMS320F28335 resulting in 24% reduction in the total loss and 50% reduction in the inductor current ripple.