The use of the conventional dual closed-loop control strategy by photovoltaic (PV) plants with grid-connected inverters may weaken the damping of a power system, which may aggravate low-frequency oscillations (LFOs). This influence will become more severe as the penetration of PV plants increases. Therefore, it is necessary to incorporate damping controls into PV plants to suppress LFOs. This paper proposed an additional compound damping control (ACDC) system that combines additional damping control (ADC) for the inverter with ADC-based dynamic power compensation control (DPCC), allowing hybrid energy storage systems (HESSs) to suppress LFOs. First, the feasibility of suppressing low-frequency oscillations in PV plants is demonstrated by the torque method and a small signal model. Then, an additional damping controller is added to the active power control link of the PV inverter to enhance the damping abilities of the system. However, given that the damping performance of PV plants with only ADC is limited by the compensated power, PV plants require devices that can rapidly compensate for the damping power. Therefore, we added the HESS to the DC bus and proposed DPCC. Finally, a three-machine nine-node system for a PV plant was modeled and simulated in the PSCAD platform. The simulation results showed that the proposed control strategy could provide effective damping for interarea oscillation.
The cascaded H-bridge static synchronous compensator (STATCOM) has been widely employed in medium- and high-voltage reactive power compensation applications due to its high modularity, fast response speed, and direct grid connection capability. However, the DC-link voltage exhibits an inherent double-frequency ripple, which poses a serious challenge to power quality. Therefore, numerous Active Power Decoupling (APD) techniques have been proposed. However, existing schemes still exhibit certain limitations: independent APD topologies are associated with higher costs, whereas single bridge-arm multiplexed APD topologies are confronted with issues such as elevated DC-side voltage and increased current stress on the multiplexed arm. Consequently, comprehensive optimization is difficult to achieve in terms of the number of power devices, decoupling accuracy, level of capacitor multiplexing, and device stress. To address the above issues, this paper proposes a DC split capacitor (DC-SC)-based dual bridge-arm multiplexed cascaded H-bridge STATCOM with active power decoupling capability, along with its corresponding control method. By constructing a fundamental-frequency common-mode voltage on the decoupling capacitor, this method effectively suppresses the double-frequency ripple in the DC-side voltage and reduces the current stress on the switching devices. The simulation and experimental results have verified the correctness and effectiveness of the proposed topological structure and control method.
With the irregular integration of small-capacity distributed generators (DG) and single-phase loads, rural low-voltage distribution transformers are faced with issues such as three-phase imbalance, light-heavy loading, and feeder terminal voltage excursions, impacting the safe and stable operation of the system. To address this issue, a coordinated control strategy based on direct power control (DPC) for low-voltage substation series-parallel coordination is proposed. A flexible interconnection topology for multi-substation series-parallel coordination is designed to achieve coordinated optimization of alternating current–direct current (AC-DC) power quality. Addressing the three-phase imbalance, light-heavy loading, and feeder terminal voltage excursions in rural low-voltage distribution transformers, a series-parallel coordinated optimization control strategy is proposed. This strategy incorporates a DC bus voltage control strategy based on sequence-separated power compensation and a closed-loop control strategy based on phase-separated power compensation, effectively addressing three-phase imbalances and load balancing in each power distribution areas. Furthermore, a series-connected phase compensation control strategy based on DPC is proposed, efficiently mitigating feeder terminal voltage excursions. A corresponding circuit model is established using Matlab/Simulink, and simulation results validate the effectiveness of the proposed strategy.