Rob Van der Straaten

Dr. Rob Van der Straaten

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


19 May 2020 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
RSRob Van der Straaten
Rob Van der Straaten
MWMariska Wesseling
Mariska Wesseling
IJIlse Jonkers
Ilse Jonkers
BVBenedicte Vanwanseele
Benedicte Vanwanseele
ABAmber K. B. D. Bruijnes
Amber K. B. D. Bruijnes
Annick TimmermansAnnick Timmermans
Annick Timmermans
Background: Apart from biomechanical alterations in movement patterns, it is known that movement limitations in persons with knee osteoarthritis (PwKOA) are related to an individual’s perception and belief regarding pain and disability. To gain more insights into the functional movement behaviour of PwKOA in a clinical setting, inertial sensor technology can be applied. This study first aims to evaluate the ability of inertial sensors to discriminate between healthy controls (HC) and PwKOA. Secondly, this study aims to determine the relationship between movement behaviour, pain-related factors and disability scores.Methods: Twelve HC and 19 PwKOA were included. Five repetitions of six functional movement tasks (walking, forward lunge, sideward lunge, ascent and descent stairs, single leg squat and sit-to-stand) were simultaneously recorded by the inertial sensor system and a camera-based motion analysis system. Statistically significant differences in angular waveforms of the trunk, pelvis and lower limb joints between HC and PwKOA were determined using one-dimensional statistical parametric mapping (SPM1D). The Knee injury and Osteoarthritis Outcome Score and TAMPA scale for Kinesiophobia were used to evaluate the relationship between discriminating joint motion, pain-related factors and disability using spearman’s correlation coefficients.Results: PwKOA had significantly less trunk rotation, internal pelvis rotation and knee flexion ROM during walking. Additionally, the reduced knee flexion (i.e. at the end of the stance phase and swing phase) was related to increased level of perceived pain. During the sideward lunge, PwKOA had significantly less knee flexion, ankle plantarflexion and hip abduction. This decreased hip abduction (i.e. during stance) was related to higher fear of movement. Finally, PwKOA had significantly less knee flexion during the forward lunge, single leg squat and during ascent and descent stairs. No significant correlations were observed with disability.Conclusions: Inertial sensors were able to discriminate between movement characteristics of PwKOA and HC. Additionally, significant relationships were found between joint motion, perceived pain and fear of movement. Since inertial sensors can be used outside the laboratory setting, these results are promising as they indicate the ability to evaluate movement deviations. Further research is required to enable measurements of small movement deviations in clinically relevant tasks.

3 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
RSRob Van der Straaten
Rob Van der Straaten
ABAmber K. B. D. Bruijnes
Amber K. B. D. Bruijnes
BVBenedicte Vanwanseele
Benedicte Vanwanseele
IJIlse Jonkers
Ilse Jonkers
LBLiesbet De Baets
Liesbet De Baets
Annick TimmermansAnnick Timmermans
Annick Timmermans
This study evaluates the reliability and agreement of the 3D range of motion (ROM) of trunk and lower limb joints, measured by inertial measurement units (MVN BIOMECH Awinda, Xsens Technologies), during a single leg squat (SLS) and sit to stand (STS) task. Furthermore, distinction was made between movement phases, to discuss the reliability and agreement for different phases of both movement tasks. Twenty healthy participants were measured on two testing days. On day one, measurements were conducted by two operators to determine the within-session and between-operator reliability and agreement. On day two, measurements were conducted by the same operator, to determine the between-session reliability and agreement. The SLS task had lower within-session reliability and agreement compared with between-session and between-operator reliability and agreement. The reliability and agreement of the hip, knee, and ankle ROM in the sagittal plane were good for both phases of the SLS task. For both phases of STS task, within-session reliability and agreement were good, and between-session and between-operator reliability and agreement were lower in all planes. As both tasks are physically demanding, differences may be explained by inconsistent movement strategies. These results show that inertial sensor systems show promise for use in further research to investigate (mal)adaptive movement strategies.

12 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Jill EmmerzaalJill Emmerzaal
Jill Emmerzaal
KCKristoff Corten
Kristoff Corten
RSRob Van der Straaten
Rob Van der Straaten
LBLiesbet De Baets
Liesbet De Baets
SRSam Van Rossom
Sam Van Rossom
BVBenedicte Vanwanseele
Benedicte Vanwanseele
This study’s aim is threefold: (I) Evaluate movement quality parameters of gait in people with hip or knee osteoarthritis (OA) compared to asymptomatic controls from a single trunk-worn 3D accelerometer. (II) Evaluate the sensitivity of these parameters to capture changes at 6-weeks, 3-, 6-, and 12-months following total knee arthroplasty (TKA). (III) Investigate whether observed changes in movement quality from 6-weeks and 12-months post-TKA relates to changes in patient-reported outcome measures (PROMs). We invited 20 asymptomatic controls, 20 people with hip OA, 18 people pre- and post-TKA to our movement lap. They wore a single trunk-worn accelerometer and walked at a self-selected speed. Movement quality parameters (symmetry, complexity, smoothness, and dynamic stability) were calculated from the 3D acceleration signal. Between groups and between timepoints comparisons were made, and changes in movement quality were correlated with PROMs. We found significant differences in symmetry and stability in both OA groups. Post-TKA, most parameters reflected an initial decrease in movement quality at 6-weeks post-TKA, which mostly normalised 6-months post-TKA. Finally, improved movement quality relates to improvements in PROMs. Thus, a single accelerometer can characterise movement quality in both OA groups and post-TKA. The correlation shows the potential to monitor movement quality in a clinical setting to inform objective, data-driven personalised rehabilitation.

6 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
LBLiesbet De Baets
Liesbet De Baets
SVStefanie Vanbrabant
Stefanie Vanbrabant
CDCarl Dierickx
Carl Dierickx
RSRob Van der Straaten
Rob Van der Straaten
Annick TimmermansAnnick Timmermans
Annick Timmermans
Adhesive capsulitis (AC) is a glenohumeral (GH) joint condition, characterized by decreased GH joint range of motion (ROM) and compensatory ROM in the elbow and scapulothoracic (ST) joint. To evaluate AC progression in clinical settings, objective movement analysis by available systems would be valuable. This study aimed to assess within-session and intra- and inter-operator reliability/agreement of such a motion capture system. The MVN-Awinda® system from Xsens Technologies (Enschede, The Netherlands) was used to assess ST, GH, and elbow ROM during four tasks (GH external rotation, combing hair, grasping a seatbelt, placing a cup on a shelf) in 10 AC patients (mean age = 54 (±6), 7 females), on two test occasions (accompanied by different operators on second occasion). Standard error of measurements (SEMs) were below 1.5° for ST pro-retraction and 4.6° for GH in-external rotation during GH external rotation; below 6.6° for ST tilt, 6.4° for GH flexion-extension, 7.1° for elbow flexion-extension during combing hair; below 4.4° for GH ab-adduction, 13° for GH in-external rotation, 6.8° for elbow flexion-extension during grasping the seatbelt; below 11° for all ST and GH joint rotations during placing a cup on a shelf. Therefore, to evaluate AC progression, inertial sensors systems can be applied during the execution of functional tasks.