Precast concrete structure is the building industrialization of the sure route. It can realize the construction process of low energy consumption and low emission and effectively meet the green development requirements of the construction industry. Based on prestressing technique, the connections of the precast concrete structure obtain prestress producing integrate joints and continuous frames, which improve the seismic safety and are applied widely in the earthquake area. To study seismic behavior of prestressed fabricated concrete frame structure, the experiments on the concrete frame under dynamic loading and low reversed cyclic loading were carried out. The single‐span three‐story prestressed fabricated concrete frame can accurately represent the load‐carrying capability and the failure mechanism of multistory frame. Results of the study show that experimental specimens have good behaviors such as full hysteresis curves, proper displacement restoring capacity, and energy dissipation; the maximum interlayer drift ratio arrives 0.27% which has no damage to the frame in small earthquakes subjected to the 102 gal peak ground acceleration; the frame is repairable in moderate earthquakes when the maximal interlayer drift ratio arrives 0.73% subjected to the 204 gal peak ground acceleration; plastic hinges appeared at the ends of beam under low reversed cyclic loading firstly where the section curvature ductility factor ranges from 3.64 to 5.62; biaxial compression is acquired at beam‐column joints with the help of column axial force and horizontal prestressing force; the beam fails before the column in the prestressed fabricated concrete frame at interlayer drift ratio between 1.56% and 2.56%.
25 August 2022 in Mechanics of Advanced Materials and Structures
Based on the low cost and superior damping performance of viscoelastic dampers, the new structural system strengthened with viscoelastic energy dissipation braces (VEDB) is proposed to upgrade the reinforced concrete frame structures with insufficient seismic capability. For the dynamic performance researches and damage evolution predictions of this structure system during earthquakes, the dynamic performance of six RCFs (reinforced concrete frames) and six VEFs (another six special reinforced concrete frames with VEDB) are studied under sinusoidal wide frequency range loading excitation horizontally. On this basis, the qualitative and quantitative relations on the damage growing at the material-level and the member-level performance deteriorating about the frame structures are conducted. Furthermore, the empirical calculation model on the cross-level damage evolution of VEFs are established and verified. Finally, a set of useful and robust cross-level judgment criteria for damage performance rates is proposed. The research found that, the installation of VEDB can significantly improve the load bearing capacity, the lateral stiffness and the energy dissipation capacity of the structures. The damage pattern of the structures is improved by VEDB, and it ensures the design criteria of “strong joints and weak members.” The empirical calculation model on the cross-level damage evolution and judgment criteria for damage performance rates proposed in this paper are useful and stable in practical engineering.
29 December 2024 in Journal of Building Engineering
Preventing progressive collapse induced by accidental events poses a critical challenge in the design and construction of resilient structures. While substantial progress has been made in planar structures, the progressive collapse mechanisms of precast concrete spatial structures—particularly regarding the effects of precast slabs—remain inadequately explored. This study develops a refined finite element modeling approach to investigate progressive collapse mechanisms in fully bonded prestressed precast concrete (FB-PPC) spatial frames, both with and without precast slabs. The modeling approach was validated against available test data from related sub-assemblies, and applied to assess the collapse performance. A series of pushdown analyses were conducted on the spatial frames under various column removal scenarios. The load–displacement curves, slab contribution, and failure modes under different conditions were compared and analyzed. A simplified energy-based dynamic assessment was additionally employed to offer a rapid estimation of the dynamic collapse capacity. The results show that when interior or side columns fail, the progressive collapse process can be divided into the beam action stage and the catenary action (CA) stage. During the beam action stage, the compressive membrane action (CMA) of the slabs and the compressive arch action (CAA) of the beams work in coordination. Additionally, the tensile membrane action (TMA) of the slabs strengthens the CA in the beams. When the corner columns fail, the collapse stages comprise the beam action stage followed by the collapse stage. Due to insufficient lateral restraints around the failed column, the development of CA is limited. The membrane action of the slabs cannot be fully mobilized. The contribution of the slabs is significant, as it can substantially enhance the vertical resistance and restrain the lateral displacement of the columns. The energy-based dynamic assessment further reveals that FB-PPC spatial frames exhibit high ductility and residual strength following sudden column removal, with dynamic load–displacement curves showing sustained plateaus or gentle slopes across all scenarios. The inclusion of precast slabs consistently enhances both the peak load capacity and the residual resistance in dynamic collapse curves.