Naoki Kato

Dr. Naoki Kato

orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2019 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
NKNaoki Kato
Naoki Kato
IYIchiro Yuki
Ichiro Yuki
TIToshihiro Ishibashi
Toshihiro Ishibashi
AIAyako Ikemura
Ayako Ikemura
IKIssei Kan
Issei Kan
YMYuichi Murayama
Yuichi Murayama
Purpose: We used an imaging technique based on 3-dimensional (3D) C-arm CT to assess the apposition of three types of stents after coiling of intracranial aneurysms.Methods: All patients with intracranial aneurysms were considered who received stent-assisted coiling with Enterprise2, Neuroform EZ, or Neuroform Atlas stents confirmed by C-arm CT imaging at our institution between June 2015 and November 2017. A 3D digital subtraction angiography (DSA) scan for vessel imaging followed by a high-resolution cone beam CT (HR-CBCT) scan for coil and stent imaging was performed. The images were fused to obtain dual volume 3D fusion images. We investigated malapposition of the stent trunk (crescent sign) and of the stent edges (edge malapposition) and used the χ2statistic to test for an association with stent types. Inter-rater agreement between two raters was estimated using Cohen’s kappa statistics.Results: We evaluated 75 consecutive cases. Enterprise2 stents were used in 22 cases, Neuroform EZ in 26, and Neuroform Atlas in 27 cases. By stent type, crescent sign was detected in 27% of Enterprise2, 8% of Neuroform EZ, and none of Neuroform Atlas stents (p=0.007), while edge malapposition was detected in 27% of Enterprise2, 58% of Neuroform EZ, and 30% of Neuroform Atlas stents (p=0.05). Excellent (κ=0.81) and good (κ=0.78) agreement between the raters was found for the detection of edge apposition and crescent sign, respectively.Conclusion: Stent malapposition was clearly visualized by dual volume 3D imaging. The Neuroform Atlas stents showed good apposition even in vessels with strong curvature.

18 March 2014 in Acta Neurochirurgica
Verified
Journal Article
Closed access
PDF file
NKNaoki Kato
Naoki Kato
SSSarah Schilt
Sarah Schilt
HSHeike Schneider
Heike Schneider
DFDietmar Frey
Dietmar Frey
MKMarkus Kufeld
Markus Kufeld
TPThomas Picht
Thomas Picht

30 January 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
AIA. Ikemura
A. Ikemura
TIT. Ishibashi
T. Ishibashi
KOKatharina Otani
Katharina Otani
IYI. Yuki
I. Yuki
TKT. Kodama
T. Kodama
YMYuichi Murayama
Yuichi Murayama
BACKGROUND AND PURPOSE: Delayed leukoencephalopathy is a rare complication that occurs after endovascular coiling of cerebral aneurysms. We aimed to describe a clinical picture of delayed leukoencephalopathy and explore potential associations with procedural characteristics. MATERIALS AND METHODS: We considered endovascular coiling procedures for cerebral aneurysms performed between January 2006 and December 2017 in our institution with follow-up MRIs. We used logistic regression models to estimate the ORs of delayed leukoencephalopathy for each procedural characteristic. RESULTS: We reviewed 1754 endovascular coiling procedures of 1594 aneurysms. Sixteen of 1722 (0.9%) procedures demonstrated delayed leukoencephalopathy on follow-up FLAIR MR imaging examinations after a median period of 71.5 days (interquartile range, 30–101 days) in the form of high-signal changes in the white matter at locations remote from the coil mass. Seven patients had headaches or hemiparesis, and 9 patients were asymptomatic. All imaging-associated changes improved subsequently. We found indications suggesting an association between delayed leukoencephalopathy and the number of microcatheters used per procedure (P = .009), along with indications suggesting that these procedures required larger median volumes of contrast medium (225 versus 175 mL, OR = 5.5, P = .008) as well as a longer median fluoroscopy duration (123.6 versus 99.3 minutes, OR = 3.0, P = .06). Our data did not suggest that delayed leukoencephalopathy was associated with the number of coils (P = .57), microguidewires (P = .35), and guiding systems (P = .57). CONCLUSIONS: Delayed leukoencephalopathy after coiling of cerebral aneurysms may have multiple etiologies such as foreign body emboli, contrast-induced encephalopathy, or hypersensitivity reaction to foreign bodies.

1 December 2020 in Journal of Stroke and Cerebrovascular Diseases
Verified
Journal Article
Closed access
NKNaoki Kato
Naoki Kato
IYIchiro Yuki
Ichiro Yuki
SHShunsuke Hataoka
Shunsuke Hataoka
CDChihebeddine Dahmani
Chihebeddine Dahmani
KOKatharina Otani
Katharina Otani
YMYuichi Murayama
Yuichi Murayama

1 November 2012 in Journal of Stroke and Cerebrovascular Diseases
Verified
Journal Article
Closed access
NKNaoki Kato
Naoki Kato
TTToshihide Tanaka
Toshihide Tanaka
YSYuta Suzuki
Yuta Suzuki
HSHiroki Sakamoto
Hiroki Sakamoto
TATakao Arai
Takao Arai
TAToshiaki Abe
Toshiaki Abe

5 July 1990 in Electronics Letters
Verified
Journal Article
Closed access
MOM. Ohhata
M. Ohhata
YYY. Yamane
Y. Yamane
TET. Enoki
T. Enoki
SSS. Sugitani
S. Sugitani
NKNaoki Kato
Naoki Kato
MHM. Hirayama
M. Hirayama
A GaAs monolithic master-slave D-type flip-flop (D-FF) IC has been developed for ultrahigh-speed optical transmission systems. The IC was designed using LSCFL (low-power source coupled FET logic) and realised by 0.15 μm gate-length MESFETs with a cut-off frequency of 65 GHz. The maximum operating speed was 13 Gb/s. This is the fastest speed ever reported for a D-FF.