Aims: The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted total knee arthroplasties (TKAs). Methods: At our retrieval centre, we measured changes in the wear and deformation of PE inserts using coordinate measuring machines and light microscopy. The amount of cement cover on the backside of tibial trays was quantified as a percentage of the total surface. The study involved data from the explanted fixed-bearing components of four widely used contemporary designs of TKA (Attune, NexGen, Press Fit Condylar (PFC), and Triathlon), revised for any indication, and we compared them with components that used previous generations of PE. Regression modelling was used to identify variables related to the amount of cement cover on the retrieved trays. Results: A total of 114 explanted fixed-bearing TKAs were examined. This included 76 used with contemporary PE inserts which were compared with 15 used with older generation PEs. The Attune and NexGen (central locking) trays were found to have significantly less cement cover than Triathlon and PFC trays (peripheral locking group) (p = 0.001). The median planicity values of the PE inserts used with central locking trays were significantly greater than of those with peripheral locking inserts (205 vs 85 microns; p < 0.001). Attune and NexGen inserts had a characteristic pattern of backside deformation, with the outer edges of the PE deviating inferiorly, leaving the PE margins as the primary areas of articulation. Conclusion: Explanted TKAs with central locking mechanisms were significantly more likely to debond from the cement mantle. The PE inserts of these designs showed characteristic patterns of deformation, which appeared to relate to the manufacturing process and may be exacerbated in vivo. This pattern of deformation was associated with PE wear occurring at the outer edges of the articulation, potentially increasing the frictional torque generated at this interface. Cite this article: Bone Joint J 2021;103-B(12):1791–1801.

2 January 2024 in The Knee
Verified
Journal Article
Closed access
RBRohan Bhalekar
Rohan Bhalekar
SWStephen R. Wells
Stephen R. Wells
MNMatthew E. Nargol
Matthew E. Nargol
SSShahrzad Shariatpanahi
Shahrzad Shariatpanahi
ANAntoni V.F. Nargol
Antoni V.F. Nargol
DLDavid J. Langton
David J. Langton

26 May 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
SHShona Haston
Shona Haston
DLDavid Langton
David Langton
DTDavid Townshend
David Townshend
RBRohan Bhalekar
Rohan Bhalekar
TJThomas Joyce
Thomas Joyce
This study aimed to characterise the damage mechanisms present on the metal components used in various contemporary total ankle replacements. Twenty-seven explanted total ankle replacements comprising 8 different designs (3 fixed bearing and 5 mobile bearing) were analysed using various explant analysis techniques. Pitting and scratching were the most commonly observed wear features. Microscopic analysis revealed metallic pitting on 52% of tibial components and 95% of talar components. Pitting was identified on more cobalt-chromium than titanium alloy tibial components (63% versus 0%). Non-contact profilometry confirmed the presence of pitting, with significant (p < 0.05) differences in the measured average surface roughness values of pitted and unpitted areas for tibial and talar components. There was macroscopically visible sliding plane scratching, indicating the presence of hard third body particles, on 78% of talar components. Changes to the non-articulating surfaces coatings in terms of coating loss and/or changes in reflectivity was identified visually on 80% of metal components. Scanning electron microscopy with energy dispersive X-ray spectroscopy identified metallic embedded debris in 19% of polyethylene inserts. This explant study demonstrates the release of metal debris from both the metallic tibial and talar component articulating surfaces and non-articulating surface coatings of various contemporary total ankle replacements. Metal particulate debris release from total ankle replacements may be more common than previously recognised. Metal debris should be considered in further study into the aetiology of failed total ankle arthroplasty.

20 December 2025 in Laws
Verified
Journal Article
Open access
PDF file
NFNicholas Farr
Nicholas Farr
EOElliot Owen
Elliot Owen
RBRohan Bhalekar
Rohan Bhalekar
The long-stop rule, under the UK Consumer Protection Act (CPA) 1987, imposes a 10-year limitation period for product liability claims, providing legal certainty for manufacturers and consumers. However, this timeframe is increasingly problematic in the case of medical devices, particularly implantable ones, which can fail decades after implantation. This review considers an extension to the long-stop period for medical devices, emphasising the need for patient protection, legal clarity, and reduced clinician burden, and contrasts the current UK system with the EU’s proposed 25-year long-stop period under the recently implemented 2024 Product Liability Directive. Through case studies, including surgical mesh and orthopaedic implants, the discussion highlights the challenges posed by delayed failure modes and the resulting difficulties in seeking redress within the 10-year window. Lastly, the role of publicly funded redress schemes and the evolving legal landscape are examined, underscoring the importance of reconsidering the current statutory limitations. Extending the long-stop period, combined with the use of explant analysis to evaluate defective medical devices, is proposed as a means to enhance patient safety and align with ongoing advancements in medical technology and regulation.

7 August 2023 in Orthopaedic Proceedings
Verified
Journal Article
Closed access
DLDavid Langton
David Langton
RBRohan Bhalekar
Rohan Bhalekar
SWStephen Wells
Stephen Wells
MNMatthew Nargol
Matthew Nargol
SWSusan Waller
Susan Waller
ANAntoni Nargol
Antoni Nargol
IS THE HIGH RATE OF TIBIAL TRAY DEBONDING IN POSTERIOR-STABILIZED NEXGEN TOTAL KNEE ARTHROPLASTY ASSOCIATED WITH BACKSIDE DEFORMATION OF POLYETHYLENE INSERTS?