Context: A variety of extubation readiness tests have already been incorporated into clinical practice in preterm infants. Objective: To identify predictor tests of successful extubation and determine their accuracy compared with clinical judgement alone. Methods: MEDLINE, Embase, PubMed, Cochrane Library and Web of Science were searched between 1984 and June 2016. Studies evaluating predictors of extubation success during a period free of mechanical inflations in infants less than 37 weeks’ gestation were included. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. After identifying and describing all predictor tests, pooled sensitivity and specificity estimates for the different test categories were generated using a bivariate random-effects model. Results: Thirty-five studies were included, showing wide heterogeneities in population characteristics, methodologies and definitions of extubation success. Assessments ranged from a few seconds to 24 hours, provided 0–6 cmH2O positive end-expiratory pressure and measured several clinical and/or physiological parameters. Thirty-one predictor tests were identified, showing good sensitivities but low and variable specificities. Given the high variation in test definitions across studies, pooling could only be performed on a subset. The commonly performed spontaneous breathing trials had pooled sensitivity of 95% (95% CI 87% to 99%) and specificity of 62% (95% CI 38% to 82%), while composite tests offered the best performance characteristics. Conclusions: There is a lack of strong evidence to support the use of extubation readiness tests in preterm infants. Although spontaneous breathing trials are attractive assessment tools, higher quality studies are needed for determining the optimal strategies for improving their accuracy.
Extremely preterm infants (≤ 28 weeks gestation) commonly require endotracheal intubation and mechanical ventilation (MV) to maintain adequate oxygenation and gas exchange. Given that MV is independently associated with important adverse outcomes, efforts should be made to limit its duration. However, current methods for determining extubation readiness are inaccurate and a significant number of infants fail extubation and require reintubation, an intervention that may be associated with increased morbidities. A variety of objective measures have been proposed to better define the optimal time for extubation, but none have proven clinically useful. In a pilot study, investigators from this group have shown promising results from sophisticated, automated analyses of cardiorespiratory signals as a predictor of extubation readiness. The aim of this study is to develop an automated predictor of extubation readiness using a combination of clinical tools along with novel and automated measures of cardiorespiratory behavior, to assist clinicians in determining when extremely preterm infants are ready for extubation. In this prospective, multicenter observational study, cardiorespiratory signals will be recorded from 250 eligible extremely preterm infants with birth weights ≤1250 g immediately prior to their first planned extubation. Automated signal analysis algorithms will compute a variety of metrics for each infant, and machine learning methods will then be used to find the optimal combination of these metrics together with clinical variables that provide the best overall prediction of extubation readiness. Using these results, investigators will develop an Automated system for Prediction of EXtubation (APEX) readiness that will integrate the software for data acquisition, signal analysis, and outcome prediction into a single application suitable for use by medical personnel in the neonatal intensive care unit. The performance of APEX will later be prospectively validated in 50 additional infants. The results of this research will provide the quantitative evidence needed to assist clinicians in determining when to extubate a preterm infant with the highest probability of success, and could produce significant improvements in extubation outcomes in this population. Clinicaltrials.gov identifier: NCT01909947 . Registered on July 17 2013. Trial sponsor: Canadian Institutes of Health Research (CIHR).
1 October 2017 in Seminars in Fetal and Neonatal Medicine
In the modern era of neonatology, mechanical ventilation has been restricted to a smaller and more immature population of extremely preterm infants. Given the adverse outcomes associated with mechanical ventilation, every effort is made to extubate these infants as early as possible. However, the scientific basis for determining extubation readiness remains imprecise and primarily guided by clinical judgement, which is highly variable and subjective. In the absence of accurate tools to assess extubation readiness, many infants fail their extubation attempt and require reintubation, which also increases complications. Recent advances in the field have led to unravelling some of the complexities surrounding extubation in this population. This review aims to synthesise the available knowledge and provide a more evidence-based approach towards the reporting of extubation outcomes and assessment of extubation readiness in extremely preterm infants.