Peder Aleksander Bjorland

Dr. Peder Aleksander Bjorland

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2019 in BMJ Paediatrics Open
Verified
Journal Article
Open access
PDF file
PBPeder Aleksander Bjorland
Peder Aleksander Bjorland
KØKnut Øymar
Knut Øymar
HEHege Langli Ersdal
Hege Langli Ersdal
SRSiren Irene Rettedal
Siren Irene Rettedal
Objectives To determine the incidence and characteristics of resuscitative interventions at different gestational ages and short-term outcomes after resuscitation. Design, setting and patients A prospective observational study in an unselected population at Stavanger University Hospital, Norway, from October 2016 until September 2017. Interventions Using a data collection form and video recordings, we registered and analysed resuscitative interventions. Main outcome measures Incidence of continuous positive airway pressure (CPAP), positive pressure ventilation (PPV), intubation, chest compressions and intravenous fluid or epinephrine boluses. Short-term outcomes of resuscitated newborns. Results All 4693 newborns in the study period were included in the study. Two hundred and ninety-one (6.2%) newborns received interventions in the first minutes of life beyond drying and stimulation. PPV was provided in 170 (3.6%) while CPAP (without PPV) was provided in 121 (2.6%) newborns. Duration of PPV was median (IQR) 106 s (54–221). Intubations were performed in 19 (0.4%) newborns, with a mean (SD) intubation time of 47 (21) s. Ten (0.2%) newborns received chest compressions and epinephrine was administrated in three (0.1%) newborns. Sixty-three per cent of the treated newborns from 34 weeks’ gestational age were returned to parental care without further follow-up. Conclusions The need for resuscitative interventions after birth was frequent in this unselected population in a high-resource setting, but full cardiopulmonary resuscitation was rare. Short-term outcomes were good, suggesting that most newborns treated with resuscitative interventions were not severely affected.

10 November 2020 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Verified
Journal Article
Open access
PDF file
PBPeder Aleksander Bjorland
Peder Aleksander Bjorland
HEHege Langli Ersdal
Hege Langli Ersdal
JEJoar Eilevstjønn
Joar Eilevstjønn
KØKnut Øymar
Knut Øymar
PDPeter Davis
Peter Davis
SRSiren Irene Rettedal
Siren Irene Rettedal
Objective To determine heart rate centiles during the first 5 min after birth in healthy term newborns delivered vaginally with delayed cord clamping. Design Single-centre prospective observational study. Setting Stavanger University Hospital, Norway, March–August 2019. Patients Term newborns delivered vaginally were eligible for inclusion. Newborns delivered by vacuum or forceps or who received any medical intervention were excluded. Interventions A novel dry electrode electrocardiography monitor (NeoBeat) was applied to the newborn’s chest immediately after birth. The newborns were placed on their mother’s chest or abdomen, dried and stimulated, and cord clamping was delayed for at least 1 min. Main outcome measures Heart rate was recorded at 1 s intervals, and the 3rd, 10th, 25th, 50th, 75th, 90th and 97th centiles were calculated from 5 s to 5 min after birth. Results 898 newborns with a mean (SD) birth weight 3594 (478) g and gestational age 40 (1) weeks were included. The heart rate increased rapidly from median (IQR) 122 (98–146) to 168 (146–185) beats per minute (bpm) during the first 30 s after birth, peaking at 175 (157–189) bpm at 61 s after birth, and thereafter slowly decreasing. The third centile reached 100 bpm at 34 s, suggesting that heart rates <100 bpm during the first minutes after birth are uncommon in healthy newborns after delayed cord clamping. Conclusion This report presents normal heart rate centiles from 5 s to 5 min after birth in healthy term newborns delivered vaginally with delayed cord clamping.

3 April 2020 in Neonatology
Verified
Journal Article
Open access
PDF file
PBPeder Aleksander Bjorland
Peder Aleksander Bjorland
HEHege Langli Ersdal
Hege Langli Ersdal
KØKnut Øymar
Knut Øymar
SRSiren Irene Rettedal
Siren Irene Rettedal
Objective: Newborn resuscitation guidelines recommend initial assessment of heart rate (HR) and initiation of positive pressure ventilation (PPV) within 60 s after birth in non-breathing newborns. Pulse oximeter (PO) and electrocardiogram (ECG) are suggested methods for continuous HR monitoring during resuscitation. Our aim was to evaluate compliance with guidelines and the efficacy of PO versus ECG monitoring in real-life newborn resuscitations. Methods: In this prospective observational study, we video recorded resuscitations of newborns ≥34 weeks of gestation receiving PPV at birth. Results: 104 resuscitations were analysed. Median (IQR) time from birth to arrival at the resuscitation bay was 48 (22–68) s (n = 62), to initial HR assessment 70 (47–118) s (n = 61), and to initiation of PPV 78 (42–118) s (n = 62). Initial HR assessment (stethoscope or palpation) and initiation of PPV were achieved within 60 s for 35% of the resuscitated newborns. Time to initial HR assessment and initiating PPV was significantly longer following vaginal deliveries than caesarean sections: 84 (70–139) versus 44 (30–66) s (p < 0.001) and 93 (73–139) versus 38 (30–66) s (p < 0.001). Time from birth and sensor application to provision of a reliable HR signal from PO versus ECG was 348 (217–524) (n = 42) versus 174 (105–277) s (n = 30) (p < 0.001) and 199 (77–352) (n = 65) versus 16 (11–22) s (n = 52) (p < 0.001). Conclusion: Initial HR assessment and initiation of PPV were achieved within 60 s after birth in only 1/3 of newborn resuscitations. When applied for continuous HR monitoring, ECG was superior to PO in time to achieve reliable HR signals in real-life resuscitations.

19 October 2021 in Children
Verified
Journal Article
Open access
PDF file
JHJoanna Haynes
Joanna Haynes
PBPeder Aleksander Bjorland
Peder Aleksander Bjorland
ØGØystein Gomo
Øystein Gomo
AUAnastasia Ushakova
Anastasia Ushakova
SRSiren Irene Rettedal
Siren Irene Rettedal
Hege L. ErsdalHege L. Ersdal
Hege L. Ersdal
Face mask ventilation of apnoeic neonates is an essential skill. However, many non-paediatric healthcare personnel (HCP) in high-resource childbirth facilities receive little hands-on real-life practice. Simulation training aims to bridge this gap by enabling skill acquisition and maintenance. Success may rely on how closely a simulator mimics the clinical conditions faced by HCPs during neonatal resuscitation. Using a novel, low-cost, high-fidelity simulator designed to train newborn ventilation skills, we compared objective measures of ventilation derived from the new manikin and from real newborns, both ventilated by the same group of experienced paediatricians. Simulated and clinical ventilation sequences were paired according to similar duration of ventilation required to achieve success. We found consistencies between manikin and neonatal positive pressure ventilation (PPV) in generated peak inflating pressure (PIP), mask leak and comparable expired tidal volume (eVT), but positive end-expiratory pressure (PEEP) was lower in manikin ventilation. Correlations between PIP, eVT and leak followed a consistent pattern for manikin and neonatal PPV, with a negative relationship between eVT and leak being the only significant correlation. Airway obstruction occurred with the same frequency in the manikin and newborns. These findings support the fidelity of the manikin in simulating clinical conditions encountered during real newborn ventilation. Two limitations of the simulator provide focus for further improvements.

1 January 2022 in Resuscitation
Verified
Journal Article
Open access
PBPeder Aleksander Bjorland
Peder Aleksander Bjorland
HEHege Langli Ersdal
Hege Langli Ersdal
JHJoanna Haynes
Joanna Haynes
AUAnastasia Ushakova
Anastasia Ushakova
KØKnut Øymar
Knut Øymar
SRSiren Irene Rettedal
Siren Irene Rettedal
T-piece resuscitators are commonly used for respiratory support during newborn resuscitation. This study aimed to describe delivered pressures and tidal volumes when resuscitating term newborns immediately after birth, using the NeoPuff T-piece resuscitator. Observational study from June 2019 through March 2021 at Stavanger University Hospital, Norway, including term newborns ventilated with a T-piece resuscitator after birth, with consent to participate. Ventilation parameters of the first 100 inflations from each newborn were recorded by respiration monitors and divided into an early (inflation 1-20) and a late (inflation 21-100) phase. Of the 7730 newborns born, 232 term newborns received positive pressure ventilation. Of these, 129 newborns were included. In the early and the late phase, the median (interquartile range) peak inflating pressure was 30 (28-31) and 30 (27-31) mbar, and tidal volume was 4.5 (1.6-7.8) and 5.7 (2.2-9.8) ml/kg, respectively. Increased inflation times were associated with an increase in volume before plateauing at an inflation time of 0.41 s in the early phase and 0.50 s in the late phase. Inflation rates exceeding 32 per minute in the early phase and 41 per minute in the late phase were associated with lower tidal volumes. There was a substantial variation in tidal volumes despite a relatively stable peak inflating pressure. Delivered tidal volumes were at the lower end of the recommended range. Our results indicate that an inflation time of approximately 0.5 s and rates around 30-40 per minute are associated with the highest delivered tidal volumes.

18 August 2025 in Children
Verified
Journal Article
Open access
PDF file
SRSiren Irene Rettedal
Siren Irene Rettedal
AKAmalie Kibsgaard
Amalie Kibsgaard
FBFrederikke Buskov
Frederikke Buskov
JEJoar Eilevstjønn
Joar Eilevstjønn
VKVilde Kolstad
Vilde Kolstad
Hege L. ErsdalHege L. Ersdal
Hege L. Ersdal
Background/Objectives: Newborn heart rate is an integral part of resuscitation algorithms, but the impact of ECG monitoring on resuscitative interventions and clinical outcomes has been identified as a knowledge gap. The objective was to evaluate the impact of routine use of dry-electrode ECG in all newborns immediately after birth on time to start positive pressure ventilation (PPV) when indicated. Methods: We conducted a randomized clinical trial from June 2019 to November 2021 at Stavanger University Hospital, Norway. Dry-electrode ECG sensors were applied immediately after birth to all newborns ≥ 34 weeks’ gestation. Randomization determined whether the heart rate display was visible or masked. Time of birth was registered in an observation app. Time to start ventilation was calculated from video recordings. Results: In total, 7343 newborns ≥ 34 weeks’ gestation were enrolled, 4284 in the intervention and 3059 in the control group, and 3.7% and 3.8% received ventilation, respectively. In 171/275 (62%) of the newborns the exact time of birth and a video of the resuscitation were available, for 98 in the intervention and 73 in the control group. Ventilation was provided within 60 s to 44/98 (45%) in the intervention and 24/73 (33%) in the control group, p = 0.12. Time from birth to start of PPV was a median of 66 (44, 102) s in the intervention and 84 (49, 148) s in the control group, p = 0.058. Resuscitated newborns were apneic (74%) or breathing ineffectively (26%) at the start of PPV, and only 36% had a heart rate < 100 beats per minute. Conclusions: The use of dry-electrode ECG heart rate monitoring did not change the proportion of newborns that received ventilation within 60 s after birth, but early termination due to employee protests to video recordings rendered the trial inadequately powered to detect a difference. Breathing status was likely a more important determinant of starting ventilation than bradycardia.