Xinyao Hu

Dr. Xinyao Hu

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2021 in Journal of Medical Internet Research
Verified
Journal Article
Open access
ZZZhong Zhao
Zhong Zhao
HTHaiming Tang
Haiming Tang
XZXiaobin Zhang
Xiaobin Zhang
XQXingda Qu
Xingda Qu
XHXinyao Hu
Xinyao Hu
JLJianping Lu
Jianping Lu
Background: Previous studies have shown promising results in identifying individuals with autism spectrum disorder (ASD) by applying machine learning (ML) to eye-tracking data collected while participants viewed varying images (ie, pictures, videos, and web pages). Although gaze behavior is known to differ between face-to-face interaction and image-viewing tasks, no study has investigated whether eye-tracking data from face-to-face conversations can also accurately identify individuals with ASD. Objective: The objective of this study was to examine whether eye-tracking data from face-to-face conversations could classify children with ASD and typical development (TD). We further investigated whether combining features on visual fixation and length of conversation would achieve better classification performance. Methods: Eye tracking was performed on children with ASD and TD while they were engaged in face-to-face conversations (including 4 conversational sessions) with an interviewer. By implementing forward feature selection, four ML classifiers were used to determine the maximum classification accuracy and the corresponding features: support vector machine (SVM), linear discriminant analysis, decision tree, and random forest. Results: A maximum classification accuracy of 92.31% was achieved with the SVM classifier by combining features on both visual fixation and session length. The classification accuracy of combined features was higher than that obtained using visual fixation features (maximum classification accuracy 84.62%) or session length (maximum classification accuracy 84.62%) alone. Conclusions: Eye-tracking data from face-to-face conversations could accurately classify children with ASD and TD, suggesting that ASD might be objectively screened in everyday social interactions. However, these results will need to be validated with a larger sample of individuals with ASD (varying in severity and balanced sex ratio) using data collected from different modalities (eg, eye tracking, kinematic, electroencephalogram, and neuroimaging). In addition, individuals with other clinical conditions (eg, developmental delay and attention deficit hyperactivity disorder) should be included in similar ML studies for detecting ASD.

1 June 2016 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
XHXinyao Hu
Xinyao Hu
XQXingda Qu
Xingda Qu
Pre-impact fall detection has been proposed to be an effective fall prevention strategy. In particular, it can help activate on-demand fall injury prevention systems (e.g. inflatable hip protectors) prior to fall impacts, and thus directly prevent the fall-related physical injuries. This paper gave a systematical review on pre-impact fall detection, and focused on the following aspects of the existing pre-impact fall detection research: fall detection apparatus, fall detection indicators, fall detection algorithms, and types of falls for fall detection evaluation. In addition, the performance of the existing pre-impact fall detection solutions were also reviewed and reported in terms of their sensitivity, specificity, and detection/lead time. This review also summarized the limitations in the existing pre-impact fall detection research, and proposed future research directions in this field.

18 April 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XHXinyao Hu
Xinyao Hu
YXYang Xu
Yang Xu
HZHaoxi Zhang
Haoxi Zhang
JXJianhao Xie
Jianhao Xie
DNDengqiang Niu
Dengqiang Niu
XQXingda Qu
Xingda Qu
The fiber Bragg grating (FBG) sensors, which have unique advantages such as small size, biocompatibility, and high sensitivity, have received much attention in hand motion tracking applications. Despite the reported good performance and potential benefits of existing FBG sensing gloves, they still face challenges in terms of glove design, wearability, motion-sensing algorithms, and system accuracy and reliability. This paper aims to provide a comprehensive survey of FBG sensing gloves, focusing on the topics of sensing characteristics, functionality, performance, system design, structure, and motion tracking algorithms. Through this survey, we have identified challenges and research gaps for FBG sensing gloves, including the need for innovation in system and structure design, the development of more advanced models that can better accommodate individual differences, and the improvement of multiplexing sensing capabilities. This survey can serve as a guide for future research in this exciting field.

1 February 2018 in Sensors
Verified
Journal Article
Open access
PDF file
XHXinyao Hu
Xinyao Hu
JZJun Zhao
Jun Zhao
DPDongsheng Peng
Dongsheng Peng
ZSZhenglong Sun
Zhenglong Sun
XQXingda Qu
Xingda Qu
Postural control is a complex skill based on the interaction of dynamic sensorimotor processes, and can be challenging for people with deficits in sensory functions. The foot plantar center of pressure (COP) has often been used for quantitative assessment of postural control. Previously, the foot plantar COP was mainly measured by force plates or complicated and expensive insole-based measurement systems. Although some low-cost instrumented insoles have been developed, their ability to accurately estimate the foot plantar COP trajectory was not robust. In this study, a novel individual-specific nonlinear model was proposed to estimate the foot plantar COP trajectories with an instrumented insole based on low-cost force sensitive resistors (FSRs). The model coefficients were determined by a least square error approximation algorithm. Model validation was carried out by comparing the estimated COP data with the reference data in a variety of postural control assessment tasks. We also compared our data with the COP trajectories estimated by the previously well accepted weighted mean approach. Comparing with the reference measurements, the average root mean square errors of the COP trajectories of both feet were 2.23 mm (±0.64) (left foot) and 2.72 mm (±0.83) (right foot) along the medial–lateral direction, and 9.17 mm (±1.98) (left foot) and 11.19 mm (±2.98) (right foot) along the anterior–posterior direction. The results are superior to those reported in previous relevant studies, and demonstrate that our proposed approach can be used for accurate foot plantar COP trajectory estimation. This study could provide an inexpensive solution to fall risk assessment in home settings or community healthcare center for the elderly. It has the potential to help prevent future falls in the elderly.

1 January 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
XHXinyao Hu
Xinyao Hu
XZXu Zeng
Xu Zeng
YXYang Xu
Yang Xu
CLChuang Luo
Chuang Luo
LJLiyao Jia
Liyao Jia
XQXingda Qu
Xingda Qu
Falls continue to be a major safety and health concern for older adults. Researchers reported that increased gait variability was associated with increased fall risks. In the present study, we proposed a novel wearable soft robotic intervention and examined its effects on improving gait variability in older adults. The robotic system used customized pneumatic artificial muscles (PAMs) to provide assistive torque for ankle dorsiflexion during walking. Twelve older adults with low fall risks and twelve with medium-high fall risks participated in an experiment. The participants were asked to walk on a treadmill under no soft robotic intervention, inactive soft robotic intervention, and active soft robotic intervention, and their gait variability during treadmill walking was measured. The results showed that the proposed soft robotic intervention could reduce step length variability for elderly people with medium-high fall risks. These findings provide supporting evidence that the proposed soft robotic intervention could potentially serve as an effective solution to fall prevention for older adults.

26 September 2023 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
XHXinyao Hu
Xinyao Hu
QDQingsong Duan
Qingsong Duan
JTJunpeng Tang
Junpeng Tang
GCGengshu Chen
Gengshu Chen
ZZZhong Zhao
Zhong Zhao
XQXingda Qu
Xingda Qu
This paper presents a novel low-cost and fully-portable instrumented shoe system for gait phase detection. The instrumented shoe consists of 174 independent sensing units constructed based on an off-the-shelf force-sensitive film known as the Velostat conductive copolymer. A zero potential method was implemented to address the crosstalk effect among the matrix-formed sensing arrays. A customized algorithm for gait event and phase detection was developed to estimate stance sub-phases including initial contact, flat foot, and push off. Experiments were carried out to evaluate the performance of the proposed instrumented shoe system in gait phase detection for both straight-line walking and turning walking. The results showed that the mean absolute time differences between the estimated phases by the proposed instrumented shoe system and the reference measurement ranged from 45 to 58 ms during straight-line walking and from 51 to 77 ms during turning walking, which were comparable to the state of art.Clinical and Translational Impact Statement—By allowing convenient gait monitoring in home healthcare settings, the proposed system enables extensive ADL data collection and facilitates developing effective treatment and rehabilitation strategies for patients with movement disorders.