Juan Manuel Mendoza Miranda

Dr. Juan Manuel Mendoza Miranda


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2013 in International Journal of Refrigeration
Verified
Journal Article
Closed access
JNJoaquín Navarro-Esbrí
Joaquín Navarro-Esbrí
JMJuan Manuel Mendoza Miranda
Juan Manuel Mendoza Miranda
Adrián Mota-BabiloniAdrián Mota-Babiloni
Adrián Mota-Babiloni
ABA. Barragán-Cervera
A. Barragán-Cervera
JBJ.M. Belman-Flores
J.M. Belman-Flores

1 November 2016 in Energy
Verified
Journal Article
Closed access
JMJuan Manuel Mendoza Miranda
Juan Manuel Mendoza Miranda
Adrián Mota-BabiloniAdrián Mota-Babiloni
Adrián Mota-Babiloni
José de Jesús Ramírez-MinguelaJosé de Jesús Ramírez-Minguela
José de Jesús Ramírez-Minguela
VMV.D. Muñoz-Carpio
V.D. Muñoz-Carpio
MCM. Carrera-Rodríguez
M. Carrera-Rodríguez
MSMercedes Salazar-Hernández
Mercedes Salazar-Hernández

1 April 2016 in Applied Thermal Engineering
Verified
Journal Article
Open access
JMJuan Manuel Mendoza Miranda
Juan Manuel Mendoza Miranda
Adrián Mota-BabiloniAdrián Mota-Babiloni
Adrián Mota-Babiloni
JNJoaquín Navarro-Esbrí
Joaquín Navarro-Esbrí
When retrofitting new refrigerants in an existing vapour compression system, their adaptation to the heat exchangers is a major concern. R450A and R448A are commercial non-flammable mixtures with low GWP developed to replace the HFCs R134a and R404A, fluids with high GWP values. In this work the evaporator performance is evaluated through a shell-and-microfin tube evaporator model using R450A, R448A, R134a and R404A. The accuracy of the model is first studied considering different recently developed micro-fin tube correlations for flow boiling phenomena. The model is validated using experimental data from tests carried out in a fully monitored vapour compression plant at different refrigeration operating conditions. The main predicted operational parameters such as evaporating pressure, UATP, and cooling capacity, when compared with experimental data, fit within ±10% using the Akhavan-Behabadi et al. correlation for flow boiling. Results show that R450A and R404A are the refrigerants in which the model fits better, even though R448A and R134a predictions are also accurate.“Ministerio de Educación, Cultura y Deporte” (Grant number FPU12/02841) for supporting this work through “Becas y Contratos de Formación de Profesorado Universitario del Programa Nacional de Formación de Recursos Humanos de Investigación del ejercicio 2012

1 January 2017 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Adrián Mota-BabiloniAdrián Mota-Babiloni
Adrián Mota-Babiloni
JNJoaquín Navarro-Esbrí
Joaquín Navarro-Esbrí
JMJuan Manuel Mendoza Miranda
Juan Manuel Mendoza Miranda
BPBernardo Peris
Bernardo Peris

28 September 2016 in Journal of Sol-Gel Science and Technology
Verified
Journal Article
Closed access
PDF file
HEHernández
Hernández
MSMercedes Salazar-Hernández
Mercedes Salazar-Hernández
MSMercedes Salazar-Hernández
Mercedes Salazar-Hernández
RCRaúl Carrera Cerritos
Raúl Carrera Cerritos
EEEnrique Elorza
Enrique Elorza
RNRicardo Navarro
Ricardo Navarro

1 January 2014 in Applied Thermal Engineering
Verified
Journal Article
Closed access
JNJoaquín Navarro-Esbrí
Joaquín Navarro-Esbrí
FMFrancisco Molés
Francisco Molés
BPBernardo Peris
Bernardo Peris
ÁBÁngel Barragán-Cervera
Ángel Barragán-Cervera
JMJuan Manuel Mendoza Miranda
Juan Manuel Mendoza Miranda
Juan Manuel BelmanJuan Manuel Belman
Juan Manuel Belman