Tara Saffari

Dr. Tara Saffari


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2025 in JPRAS Open
Verified
Journal Article
Open access
DJDaehee Jeong
Daehee Jeong
TSTara Saffari
Tara Saffari
ALAmy Liao
Amy Liao
SISara Iskeirjeh
Sara Iskeirjeh
GSGary Skolnick
Gary Skolnick
SBSaif Badran
Saif Badran
Microstomia is characterized by a reduced oral aperture, leading to impairments in speech, feeding, dental hygiene, and facial expressions. Nonsurgical treatments offer limited benefits for mild cases although surgical interventions have been shown to yield better outcomes. However, the unique anatomical challenges and limited availability of adjacent tissue present obstacles in surgical management of this condition. This review aims to provide a comprehensive summary of the reported surgical techniques for microstomia management and discuss their specific indications, advantages, and potential limitations. A comprehensive review was conducted in June 2024 to identify studies that have reported on the surgical techniques for microstomia management. A database search was performed on Medline, Embase, Scopus, and Web of Science. The study findings have been reported as per the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Quality assessment was conducted using the Case Report (CARE) guidelines and Methodological Index for Non‐randomized Studies (MINORS) assessment. The search yielded a total of 1315 studies; of these, 28 met the inclusion criteria following a full-text screening. Ten surgical techniques for microstomia management were identified and categorized into the following three reconstructive modalities: grafts, local tissue transfer, and autologous free tissue transfer. The average scores of the CARE and MINORS assessments were 27.20/30 and 11.33/14 respectively. Selection of the appropriate surgical technique is critical for achieving successful results in microstomia reconstruction. The primary objective is to enlarge the oral opening while preserving oral function and achieving satisfactory cosmetic outcomes. The key considerations for choosing a surgical technique include contracture severity, perioral tissue availability, and the surgeon's familiarity with different surgical options.

11 June 2025 in Biophotonics Discovery
Verified
Journal Article
Open access
APArjun Putcha
Arjun Putcha
KSKevin Schichlein
Kevin Schichlein
TNTien Nguyen
Tien Nguyen
BDBrayden Davis
Brayden Davis
RCRachel Choffin
Rachel Choffin
Wubin BaiWubin Bai
Wubin Bai
SignificancePulse oximeters are frequently used in healthcare settings to noninvasively estimate blood oxygen levels in patients, in turn influencing clinical decision-making. However, numerous studies have found pulse oximeters consistently overestimate oxygen levels in patients of color, with this overestimation increasing as oxygen levels decline. Although some reports postulate skin pigmentation may be the source of bias, to our knowledge, the precise impact of skin pigmentation on pulse oximetry has not been elucidated.AimOur objective is to experimentally characterize the impact of skin pigmentation on pulse oximeters across a broad range of oxygen saturations and determine whether skin pigmentation can explain the observed pulse oximeter bias in patients of color.ResultsUsing a live porcine model, we experimentally demonstrate the impact of skin pigmentation on pulse oximeter calculation. In particular, we show that skin pigmentation attenuates the sensitivity of red-light absorption to changes in oxygen saturation and show that the pulse oximeter output is consequently attenuated in pigmented skin.ConclusionThe systematic animal experiments confirm the confounding impact of skin pigmentation on intermediate calculations of pulse oximetry, and validate existing clinical observations of pulse oximeter bias in patients of color.

29 May 2026 in Science Advances
Verified
Journal Article
Open access
Kenneth MadsenKenneth Madsen
Kenneth Madsen
DHDane Hintermueller
Dane Hintermueller
EOElliot A. Opel
Elliot A. Opel
JRJoseph G. Ribaudo
Joseph G. Ribaudo
TSTara Saffari
Tara Saffari
JRJohn A. Rogers
John A. Rogers
The loss or suppression of local metabolic function in living tissues brought about by a lack of oxygen availability (ischemia) serves as the origin for myriad life-threatening conditions including stroke, heart failure, and peripheral ischemic injury. Despite the pressing clinical need to evaluate local tissue health, platforms that support such analysis remain elusive. To address this need, we present a wireless, minimally invasive, multianalyte, electrochemical probe supporting the continuous profiling of local metabolites including K + and pH, and the semicontinuous profiling of lactic acid. We validate the analytical capabilities of our sensing system by ion profiling in arterial whole blood. Furthermore, we use acute compartment syndrome as a model for tissue ischemia and use our percutaneously implanted probes to track metabolic changes in living muscle in real time.

21 August 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
SBSaif Badran
Saif Badran
TSTara Saffari
Tara Saffari
WMWilliam Moritz
William Moritz
GSGary Skolnick
Gary Skolnick
AWAmanda Westman
Amanda Westman
Justin M. SacksJustin M. Sacks
Justin M. Sacks
Accurate monitoring of mastectomy skin flap (MSF) perfusion is critical, especially in patients with darker skin pigmentation at higher risk of misdiagnosed tissue ischemia. Near-infrared spectroscopy (NIRS) devices, such as SnapshotNIR, offer real-time tissue oxygen saturation measurements (StO2), but their accuracy across skin pigmentation levels remains unexplored. This quasi-experimental study included 33 patients undergoing mastectomy. MSF edge ΔStO2, defined as preoperative minus postoperative StO2, was measured using SnapshotNIR device (Kent Imaging, Calgary, AB, Canada) pre- and post-mastectomy. By definition, a positive ΔStO2 indicates a decrease in tissue oxygenation, while a negative ΔStO2 indicates an increase relative to baseline. ΔStO2 was analyzed against Fitzpatrick scores to assess skin pigmentation impact on measurement accuracy. ΔStO2 (mean ± SD) progressively decreased with increasing Fitzpatrick score: 14.0 ± 22.98 for score 1, 6.87 ± 17.45 for score 2, −3.13 ± 6.89 for score 3, and −40.75 ± 22.27 for score 5, indicating a shift from positive to negative O2 change. Fitzpatrick scores significantly correlated with ΔStO2 (ρ = −0.392, p = 0.016). ANOVA confirmed differences (p = 0.008), with Tukey’s post hoc testing showing significant differences between Fitzpatrick scores 1 and 5 (p = 0.022), and 2 and 5 (p = 0.006). SnapshotNIR technology demonstrated measurable sensitivity for detecting changes in StO2 and predicting ischemia; however, NIRS-based devices may overestimate oxygenation in darker skin pigmentation, highlighting a need for device calibration to improve accuracy across skin tones.

1 October 2025 in Surgical Innovation
Verified
Journal Article
Closed access
TSTara Saffari
Tara Saffari
EOEsther Ochoa
Esther Ochoa
DCDaniel Colchado
Daniel Colchado
ALAmy Liao
Amy Liao
JSJustin M. Sacks
Justin M. Sacks
Xiaowei LiXiaowei Li
Xiaowei Li
Arteriovenous fistulas (AVFs) are the gold standard for vascular access to facilitate hemodialysis, yet traditional surgical techniques are technically demanding, time-intensive, and costly. Additionally, limited suitable AVF sites, due to patient anatomy, vessel quality, and prior access exhaustion, necessitate exploration of novel options. This cadaveric proof-of-concept study introduces the anterior interosseous artery-cephalic vein as a novel AVF site and evaluates the feasibility of a 3D-printed sutureless anastomotic device, the Vaso-Stent, compared to conventional handsewn techniques. Fresh-frozen cadaveric upper limbs were procured to test the surgical feasibility of the proposed AVF model. Surgical exposure of the interosseous artery and adjacent cephalic vein were uncomplicated. A 3D-printed Vaso-Stent was manufactured and facilitated efficient anastomosis in under 1 min, compared with the 4.5 min required for a standard handsewn technique. The device demonstrated ease of placement, robust structural integrity, and resistance to tensile forces. These findings highlight that the Vaso-Stent can provide a simple alternative for AVF creation that reduces operative time and highlight the anterior interosseous artery-cephalic vein configuration as a new and unique hemodialysis access opportunity.

5 January 2022 in Plastic and Reconstructive Surgery - Global Open
Verified
Journal Article
Open access
TSTiam M. Saffari
Tiam M. Saffari
Francis Ka Leung ChanFrancis Ka Leung Chan
Francis Ka Leung Chan
TSTara Saffari
Tara Saffari
KZK.J. Zuo
K.J. Zuo
GBGregory H Borschel
Gregory H Borschel
ASAlexander Y. Shin
Alexander Y. Shin