This paper presents a novel ultrafast DC circuit breaker concept based on a railgun actuator, designed for ultrafast charging stations operating at 800 and delivering up to 640 . The proposed breaker achieves contact opening speeds exceeding 190 /, enabling fault current interruption within 200 and limiting the peak fault current to 2200 . This performance significantly reduces breaker stress compared with conventional mechanical solutions. System-level simulations demonstrate a dramatic reduction in energy dissipation during faults—from 11,000 J with a conventional fast breaker to just 250 using the proposed design. A 3D finite element method model of the railgun actuator confirms the feasibility of achieving a 15 stroke in 150 . The evolution of current density and magnetic field is analyzed, highlighting the influence of skin and velocity skin effects. Results confirm that the proposed solution acts both as a circuit breaker and a fault current limiter, enhancing safety, reliability, and durability in high-power DC systems.
This paper presents a novel railgun simulation model based on a quasistatic study in COMSOL. Traditional analytical models are inaccurate as they use the coenergy principle to calculate the force on the armature, yielding the total force in the displacement axis. By using a numerical magnetic solution, a parametric analysis evaluates the flux linkage, armature force, and system resistance at various positions and currents. After characterizing the railgun, the transient problem is solved by coupling the parametric study results with the system's equivalent circuit. Finally, the results are compared with those from the analytical approach.