We are interested in developing a vaccine that prevents genital herpes. Adjuvants have a major impact on vaccine immunogenicity. We compared two adjuvants, an experimental Merck Sharp & Dohme lipid nanoparticle (LNP) adjuvant, LNP-2, with CpG oligonucleotide combined with alum for immunogenicity in mice when administered with herpes simplex virus type 2 (HSV-2) glycoproteins C, D and E (gC2, gD2, gE2). The immunogens are intended to produce neutralizing antibodies to gC2 and gD2, antibodies to gD2 and gE2 that block cell-to-cell spread, and antibodies to gE2 and gC2 that block immune evasion from antibody and complement, respectively. Overall, CpG/alum was better at producing serum and vaginal IgG binding antibodies, neutralizing antibodies, antibodies that block virus spread from cell-to-cell, and antibodies that block immune evasion domains on gC2. We used a novel high throughput biosensor assay to further assess differences in immunogenicity by mapping antibody responses to seven crucial epitopes on gD2 involved in virus entry or cell-to-cell spread. We found striking differences between CpG/alum and LNP-2. Mice immunized with gD2 CpG/alum produced higher titers of antibodies than LNP-2 to six of seven crucial epitopes and produced antibodies to more crucial epitopes than LNP-2. Measuring epitope-specific antibodies helped to define mechanisms by which CpG/alum outperformed LNP-2 and is a valuable technique to compare adjuvants.
18 April 2019 in IEEE Reviews in Biomedical Engineering
The interests in the effects of radio frequency (RF) on biological systems has increased. This interest has increased partially due to the advancements and increase implementations of RF into technology. As research in the area has progressed, the reliability and reproducibility of those experiments has not crossed multidisciplinary boundaries. Therefore, as researchers, it is imperative to understand the various exposure systems available as well as the aspects, both electromagnetic and biological, needed to produce a sound exposure experiment. This systematic review examines common radio frequency exposure methods for both in vitro and in vivo studies. For in vitro studies, discussion of possible biological limitations to consider were also emphasized. The validity of the examined methods, for both in vitro and in vivo, were analyzed by discussing the advantages and disadvantages of each. This review offers guidance for researchers to assist in the development of an RF exposure experiment that crosses current multidisciplinary boundaries.
Return bends are frequently encountered in microfluidic systems. In this study, a three-dimensional spectral boundary element method for interfacial dynamics in Stokes flow has been adopted to investigate the dynamics of viscous droplets in rectangular return bends. The droplet trajectory, deformation, and migration velocity are investigated under the influence of various fluid properties and operational conditions, which are depicted by the Capillary number, viscosity ratio, and droplet size, as well as the dimensions of the return bend. While the computational results provide information for the design of return bends in microfluidic systems in general, the computational framework shows potential to guide the design and operation of a droplet-based microfluidic delivery system for cell seeding.