This paper presents an observer-based robust control (ORC) scheme, combining perturbation observers with fractional-order sliding-mode regulators, for the current control of rotor-side converter (RSC) of a doubly-fed induction generator (DFIG). Perturbation states are defined to describe the interactions between d-axis and q-axis rotor current loops. The decoupled current control of RSC is realized via fractional-order sliding-mode output feedback control and perturbation compensation based on the estimation states obtained by perturbation observers. The proposed ORC scheme does not require any parameters of DFIG and it is robust to system uncertainties and external disturbances. Experimental tests are undertaken on a hardware-in-the-loop DFIG system to verify the control performance of ORC scheme.
Boost converters with one cycle control (OCC) are prone to exhibit oscillations as the Hopf bifurcation, which may degrade performances and limit the parameter stable region of converters. This work proposed a novel control strategy for suppressing such bifurcations and enlarging the parameter stability region of the boost system on the basis of the principle of energy balance in the circuit. Through analyzing of the stability and bifurcation condition, the results reflect that, the energybased OCC can adjust the poles of the system transfer function, which ensures the stable operation of the system in an extended range of circuit parameters. Moreover, the orders of the transfer function will not be increased by such adjustments, thus the computational complexity of the transfer function will be increased. The theoretical analysis demonstrates the ability of the energy-based OCC for suppressing the bifurcations and enlarging the stable region of the system parameters. The results by simulation and experiment further prove the effectiveness of the proposed control strategy.
Power Factor Correction (PFC) converters are widely used in engineering. A classical PFC control circuit employs two complicated feedback control loops and a multiplier, while the One-Cycle-Controlled (OCC) PFC converter has a simple control circuit. In OCC PFC converters, the voltage loop is implemented with a PID control and the multiplier is not needed. Although linear theory is used in designing the OCC PFC converter control circuit, it cannot be used in predicting non-linear phenomena in the converter. In this paper, a non-linear model of the OCC PFC Boost converter is proposed based on the double averaging method. The line frequency instability of the converter is predicted by studying the DC component, the first harmonic component and the second harmonic component of the main circuit and the control circuit. The effect of the input voltage and the output capacitance on the stability of the converter is studied. The correctness of the proposed model is verified with numerical simulations and experimental measurements.
The One-Cycle Controlled Boost Power Factor Correction converter has one voltage control loop, which may exhibit instability when the load is light. The instability results in a low Power Factor. To ensure that the Power Factor is high, a time delay circuit was adopted in this paper to control the instability of the converter. The architecture of the time delay circuit is described, and its transfer function is derived. The double averaging method was applied to the converter to determine the parameters in the control method. Experimental results verified the time delay control method in the converter. The power factor increased from 0.82 to 0.99 after activating the delay control circuit.
The previously developed control methods based on the conservation of energy in circuits require the accurate estimation of energy losses, which is difficult to measure and calculate for boost converters. Consequently, there always exist steady-state errors in the output voltage if neglecting such circuit energy losses. To address this issue, an improved energy balance control (IEBC) method is proposed in this paper by integrating a simplified energy balance controller (SEBC) with a PI controller. The proposed IEBC can reduce the steady-state output voltage errors without requiring the estimation of circuit energy losses. Furthermore, the proposed IEBC can operate in both the continuous current mode (CCM) and the discontinuous current mode (DCM), thus accurate static and fast dynamic performances are achieved over the entire load operation range. Moreover, the stability of the IEBC is proved using the Lyapunov stability criterion. Compared with that of the SEBC, both simulations and experiments validate the feasibility and robustness of the proposed IEBC method.