1 April 2004 in British Journal of Radiology
Verified
Journal Article
Closed access
DBD Bor
D Bor
TST Sancak
T Sancak
TOTuran Olgar
Turan Olgar
YEY Elcim
Y Elcim
AAA Adanali
A Adanali
SAS Akyar
S Akyar
In this study, measurements of dose-area product (DAP) and entrance dose were carried out simultaneously in a sample of 162 adult patients who underwent different interventional examinations. Effective doses for each measurement technique were estimated using the conversion factors that have been determined for specific X-ray views in a mathematical phantom. Exposure conditions used in clinical practice never match these theoretical models exactly, and deviations from the assumed standard conditions cause uncertainties in effective dose estimations. Higher effective dose values are found if the air kerma results are used rather than DAP readings, both for patient and Rando phantom studies. Comparison of DAP, fluoroscopy times and skin doses were made with published data. DAP measurement for the effective dose calculation and thermoluminescent dosimeter for the skin dose estimates are found to be the most reliable methods for patient dosimetry.

18 August 2009 in Journal of Radiological Protection
Verified
Journal Article
Closed access
MSM Safak
M Safak
TOTuran Olgar
Turan Olgar
DBD Bor
D Bor
GBG Berkmen
G Berkmen
CGC Gogus
C Gogus
Renal stones can be treated either by extracorporeal shock wave lithotripsy (ESWL) or percutaneous nephrolithotomy (PCNL). Increasing use of fluoroscopic exposure for access and to detect stone location during PCNL make the measurement of patient and staff doses important. The main objective of this work was to assess patient and urologist doses for the PCNL examination. We used the tube output technique for determination of patient doses (n = 20) and lithium fluoride thermoluminescent dosimeter (TLD) chips for urologist dose measurements. The TLD technique was also used for some patient dose measurements (n = 7) for comparison with the tube output technique. Mean entrance skin doses of 191 and 117 mGy were measured by the tube output technique for anterior-posterior (AP) and right anterior oblique (RAO) 30 degrees /left anterior oblique (LAO) 30 degrees projections, respectively. The mean urologist doses for eye, finger and collar were measured as 26, 33.5 and 48 microGy per procedure, respectively. The mean effective dose per procedure for the urologist was 12.7 microSv. None of the individual skin dose results approach deterministic levels.

1 March 2009 in Physica Medica
Verified
Journal Article
Closed access
DBDogan Bor
Dogan Bor
TOTuran Olgar
Turan Olgar
TTTürkay Toklu
Türkay Toklu
AÇAyça Çağlan
Ayça Çağlan
EÖElif Önal
Elif Önal
RPRenato Padovani
Renato Padovani

18 June 2012 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
TOTuran Olgar
Turan Olgar
TKT. Kahn
T. Kahn
DGD. Gosch
D. Gosch
Purpose: To determine the average glandular dose (AGD) in digital full-field mammography (2 D imaging mode) and in breast tomosynthesis (3 D imaging mode). Materials and Methods: Using the method described by Boone, the AGD was calculated from the exposure parameters of 2247 conventional 2 D mammograms and 984 mammograms in 3 D imaging mode of 641 patients examined with the digital mammographic system Hologic Selenia Dimensions. The breast glandular tissue content was estimated by the Hologic R2 Quantra automated volumetric breast density measurement tool for each patient from right craniocaudal (RCC) and left craniocaudal (LCC) images in 2 D imaging mode. Results: The mean compressed breast thickness (CBT) was 52.7 mm for craniocaudal (CC) and 56.0 mm for mediolateral oblique (MLO) views. The mean percentage of breast glandular tissue content was 18.0 % and 17.4 % for RCC and LCC projections, respectively. The mean AGD values in 2 D imaging mode per exposure for the standard breast were 1.57 mGy and 1.66 mGy, while the mean AGD values after correction for real breast composition were 1.82 mGy and 1.94 mGy for CC and MLO views, respectively. The mean AGD values in 3 D imaging mode per exposure for the standard breast were 2.19 mGy and 2.29 mGy, while the mean AGD values after correction for the real breast composition were 2.53 mGy and 2.63 mGy for CC and MLO views, respectively. No significant relationship was found between the AGD and CBT in 2 D imaging mode and a good correlation coefficient of 0.98 in 3 D imaging mode. Conclusion: In this study the mean calculated AGD per exposure in 3 D imaging mode was on average 34 % higher than for 2 D imaging mode for patients examined with the same CBT. Ziel: Bestimmung der mittleren Parenchymdosis bei der digitalen Vollfeldmammografie (2D-Modus) und bei der Brusttomosynthese (3D-Modus). Material und Methoden: Die mittlere Parenchymdosis wurde nach der Methode von Boone aus den Expositionsparametern von 2247 konventionellen 2D-Mammografieaufnahmen und von 984 Aufnahmen im 3D-Modus von 641 Patienten berechnet, die mit einem digitalen Mammografiegerät Hologic Selenia Dimensions angefertigt wurden. Der Anteil des fibroglandulären Gewebes wurde für jede Patientin aus den rechten kranio-kaudalen (RCC) und linken kranio-kaudalen (LCC) 2D-Aufnahmen mittels des Hologic-R2-Quantra-Softwareprogramms zur volumetrischen Auswertung der Brust ermittelt. Die mittlere Parenchymdosis wurde für eine Standardzusammensetzung des Brustgewebes (jeweils 50 % Anteil von fibroglandulären und von Fettgewebe) und die tatsächliche Gewebezusammensetzung berechnet. Ergebnisse: Die mittlere Kompressionsschichtdicke betrug 52,7 mm für kranio-kaudale (CC) und 56,0 mm für mediolateral-oblique (MLO) Projektionen. Der mittlere Anteil des fibroglandulären Gewebes lag bei 18,0 % für RCC und 17,4 % für LCC-Aufnahmen. Die mittlere Parenchymdosis pro Aufnahme im 2D-Modus für eine Standardbrustzusammensetzung betrug 1,57 mGy für CC und 1,66 mGy für MLO-Projektionen bzw. 1,82 mGy und 1,94 mGy für die tatsächliche Brustzusammensetzung. Die mittlere Parenchymdosis pro Aufnahme im 3D-Modus für eine Standardbrustzusammensetzung betrug 2,19 mGy für CC und 2,29 mGy für MLO-Projektionen bzw. 2,53 mGy und 2,63 mGy für die tatsächliche Brustzusammensetzung. Schlussfolgerung: In dieser Studie war für Patienten mit gleicher Kompressionsschichtdicke die mittlere Parenchymdosis im 3D-Modus im Mittel 34 % höher als im 2D-Modus.

1 January 2008 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
TOTuran Olgar
Turan Olgar
EOEsra Onal
Esra Onal
DBDogan Bor
Dogan Bor
NONurullah Okumus
Nurullah Okumus
YAYildiz Atalay
Yildiz Atalay
EKEsin Koc
Esin Koc
Olgar T, et al. Korean J Radiol. 2008 Sep-Oct;9(5):416-419. http://dx.doi.org/10.3348/kjr.2008.9.5.416

18 August 2009 in Journal of Radiological Protection
Verified
Journal Article
Closed access
TOTuran Olgar
Turan Olgar
DBD Bor
D Bor
GBG Berkmen
G Berkmen
TYT Yazar
T Yazar
The aim of this study was to measure patient and staff doses simultaneously for some complex x-ray examinations. Measurements of dose-area product (DAP) and entrance skin dose (ESD) were carried out in a sample of 107 adult patients who underwent different x-ray examinations such as double contrast barium enema (DCBE), single contrast barium enema (SCBE), barium swallow, endoscopic retrograde cholangiopancreatography (ERCP) and percutaneous transhepatic cholangiography (PTC), and various orthopaedic surgical procedures. Dose measurements were made separately for each projection, and DAP, thermoluminescent dosimetry (TLD), film dosimetry and tube output measurement techniques were used. Staff doses were measured simultaneously with patient doses for these examinations, with the exception of barium procedures. The measured mean DAP values were found to be 8.33, 90.24, 79.96 Gy cm(2) for barium swallow, SCBE and DCBE procedures with the fluoroscopy times of 3.1, 4.43 and 5.86 min, respectively. The calculated mean DAP was 26.33 Gy cm(2) for diagnostic and 89.76 Gy cm(2) therapeutic ERCP examinations with the average fluoroscopy times of 1.9 and 5.06 min respectively. Similarly, the calculated mean DAP was 97.53 Gy cm(2) with a corresponding fluoroscopy time of 6.1 min for PTC studies. The calculated mean entrance skin dose (ESD) was 172 mGy for the orthopaedic surgical studies. Maximum skin doses were measured as 324, 891, 1218, 750, 819 and 1397 mGy for barium swallow, SCBE, DCBE, ERCP, PTC and orthopaedic surgical procedures, respectively. The high number of radiographs taken during barium enema examinations, and the high x-ray outputs of the fluoroscopic units used in ERCP, were the main reasons for high doses, and some corrective actions were immediately taken.