View All Publications
17 September 2025 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
MIMahdi Islam
Mahdi Islam
MTMusarrat Tabassum
Musarrat Tabassum
AMAgnes Mayr
Agnes Mayr
CKChristian Kremser
Christian Kremser
Markus HaltmeierMarkus Haltmeier
Markus Haltmeier
EAEnrique Almar-Munoz
Enrique Almar-Munoz
Transcatheter aortic valve implantation (TAVI) is a minimally invasive procedure for treating severe aortic stenosis, where optimal vascular access route selection is critical to reduce complications. It requires careful selection of the iliac artery with the most favourable anatomy, specifically, one with the largest diameters and no segments narrower than 5 mm. This process is time-consuming when carried out manually. We present an active learning-based segmentation framework for contrast-enhanced Cardiac Magnetic Resonance (CMR) data, guided by probabilistic uncertainty and pseudo-labelling, enabling efficient segmentation with minimal manual annotation. The segmentations are then fed into an automated pipeline for diameter quantification, achieving a Dice score of 0.912 and a mean absolute percentage error (MAPE) of 4.92%. An ablation study using pre- and post-contrast CMR showed superior performance with post-contrast data only. Overall, the pipeline provides accurate segmentation and detailed diameter profiles of the aorto-iliac route, helping the assessment of the access route.