JEAN PIERRE MALLET

Dr. JEAN PIERRE MALLET

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2019 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
MRMicaela Romagnoli
Micaela Romagnoli
TCThomas V. Colby
Thomas V. Colby
JBJean-Philippe Berthet
Jean-Philippe Berthet
AGAnne Sophie Gamez
Anne Sophie Gamez
JMJEAN PIERRE MALLET
JEAN PIERRE MALLET
ABArnaud Bourdin
Arnaud Bourdin
Rationale: The diagnostic concordance between transbronchial lung cryobiopsy (TBLC)—versus surgical lung biopsy (SLB) as the current gold standard—in interstitial lung disease (ILD) cases requiring histology remains controversial. Objectives: To assess diagnostic concordance between TBLC and SLB sequentially performed in the same patients, the diagnostic yield of both techniques, and subsequent changes in multidisciplinary assessment (MDA) decisions. Methods: A two-center prospective study included patients with ILD with a nondefinite usual interstitial pneumonia pattern (on high-resolution computed tomography scan) confirmed at a first MDA. Patients underwent TBLC immediately followed by video-assisted thoracoscopy for SLB at the same anatomical locations. After open reading of both sample types by local pathologists and final diagnosis at a second MDA (MDA2), anonymized TBLC and SLB slides were blindly assessed by an external expert pathologist (T.V.C.). Kappa-concordance coefficients and percentage agreement were computed for: TBLC versus SLB, MDA2 versus TBLC, MDA2 versus SLB, and blinded pathology versus routine pathology. Measurements and Main Results: Twenty-one patients were included. The median TBLC biopsy size (longest axis) was 7 mm (interquartile range, 5–8 mm). SLB biopsy sizes averaged 46.1 ± 13.8 mm. Concordance coefficients and percentage agreement were: TBLC versus SLB: κ = 0.22 (95% confidence interval [CI], 0.01–0.44), percentage agreement = 38% (95% CI, 18–62%); MDA2 versus TBLC: κ = 0.31 (95% CI, 0.06–0.56), percentage agreement = 48% (95% CI, 26–70)%; MDA2 versus SLB: κ = 0.51 (95% CI, 0.27–0.75), percentage agreement = 62% (95% CI, 38–82%); two pneumothoraces (9.5%) were recorded during TBLC. TBLC would have led to a different treatment if SLB was not performed in 11 of 21 (52%) of cases. Conclusions: Pathological results from TBLC and SLB were poorly concordant in the assessment of ILD. SLBs were more frequently concordant with the final diagnosis retained at MDA.

15 January 2021 in Respiratory Research
Verified
Journal Article
Open access
PDF file
MRMarie-Caroline Rotty
Marie-Caroline Rotty
CSCarey Suehs
Carey Suehs
JMJEAN PIERRE MALLET
JEAN PIERRE MALLET
CMChristian Martinez
Christian Martinez
JBJean-Christian Borel
Jean-Christian Borel
DJDany Jaffuel
Dany Jaffuel
Background: For some patients, Continuous Positive Airway Pressure (CPAP) remains an uncomfortable therapy despite the constant development of technological innovations. To date, no real life study has investigated the relationship between mask related side-effects (MRSEs) and CPAP-non-adherence (defined as < 4 h/day) or residual-excessive-sleepiness (RES, Epworth-Sleepiness-Scale (ESS) score ≥ 11) in the long-term. Methods: The InterfaceVent-CPAP study is a prospective real-life cross-sectional study conducted in an apneic adult cohort undergoing at least 3 months of CPAP with unrestricted mask-access (34 different masks). MRSEs were evaluated using visual-analogue-scales, CPAP-data using CPAP-software, sleepiness using ESS. Results: 1484 patients were included in the analysis (72.2% male, median age 67 years (IQ25–75: 60–74), initial Apnea–Hypopnea-Index (AHI) of 39 (31–56)/h, residual AHIflow was 1.9 (0.9–4) events/h), CPAP-treatment lasted 4.4 (2.0–9.7) years, CPAP-usage was 6.8 (5.5–7.8) h/day, the prevalence of CPAP-non-adherence was 8.6%, and the prevalence of RES was 16.17%. Leak-related side-effects were the most prevalent side-effects (patient-reported leaks concerned 75.4% of responders and had no correlation with CPAP-reported-leaks). Multivariable logistic regression analyses evaluating explanatory-variable (demographic data, device/mask data and MRSEs) effects on variables-of-interest (CPAP-non-adherence and RES), indicated for patient-MRSEs significant associations between: (i) CPAP-non-adherence and dry-mouth (p = 0.004); (ii) RES and patient-reported leaks (p = 0.007), noisy mask (p < 0.001), dry nose (p < 0.001) and harness pain (p = 0.043). Conclusion: In long-term CPAP-treated patients, leak-related side-effects remain the most prevalent side-effects, but patient-reported leaks cannot be predicted by CPAP-reported-leaks. Patient-MRSEs can be independently associated with CPAP-non-adherence and RES, thus implying a complementary role for MRSE questionnaires alongside CPAP-device-reported-data for patient monitoring. Trial registration InterfaceVent is registered with ClinicalTrials.gov (NCT03013283).

4 March 2022 in Respiratory Research
Verified
Journal Article
Open access
PDF file
FBFanny Bertelli
Fanny Bertelli
CSCarey Suehs
Carey Suehs
JMJEAN PIERRE MALLET
JEAN PIERRE MALLET
ICIsabelle Court-Fortune
Isabelle Court-Fortune
FGFrederic Gagnadoux
Frederic Gagnadoux
DJDany Jaffuel
Dany Jaffuel
Background: Whether the COVID-19 pandemic impacts Positive Airway Pressure (PAP) adherence over the long-term is unknown and only preliminary short-term data have been reported. Methods: With the aim of describing the impact of the first and second waves of COVID-19 on PAP adherence during 2020 in France, we designed a cross-sectional study of Sleep-Apnea (SA)-patients under PAP telemonitoring. To examine PAP adherence in adult SA patients, we assessed de-identified data from a non-profit healthcare provider database during the period January 1, 2019 to December 31, 2020. Included patients met the following criteria: (i) PAP-treated for at least 4 months before January 1, 2019 and with continuous PAP during both 2019 and 2020; (ii) ≥ 360 daily PAP telemonitored data per year. For PAP adherence, data were collected using the PAP-software. Results: 8477/10482 patients were finally included in the analysis [72.4% male, median age 70 years (IQ25–75: 61–77], 25.6% < 62 years old, initial Apnea–Hypopnea Index (AHI) of 41 (31–59)/h. Median PAP adherence was 7.21 (6.12–8.10) h/day in 2020 versus 7.12 (6.05–8.02) h/day in 2019, p < 0.001. The median difference in PAP adherence between the first 2020 lockdown and the corresponding 2019 weeks was 9.75 (CI95% 8.75–10.75) min/day, p < 0.001. The median difference in PAP adherence between the second 2020 lockdown and the corresponding 2019 weeks was 5.00 (CI95% 4.00–6.00) min/day, p < 0.001. If we consider the minimal clinically important difference of 30 min for PAP adherence, 30.4% and 26% of the patients increased their PAP adherence by at least 30 min during the first and second lockdowns respectively; 17.6% and 19.3% of the patients lowered their PAP adherence by at least 30 min in the first and second lockdowns, respectively. Conclusion: During the first and second lockdowns, the COVID-19 pandemic had a clinically irrelevant effect on PAP adherence for the study population. Future studies are needed to describe COVID-19 pandemic impact on PAP adherence not only for long-term PAP-treated SA patients but also for incident cases. Trial registration The COVADENE study was registered on March 1st, 2021 on ClinicalTrials.gov (Identifier: NCT04775966)

21 September 2020 in Respiratory Research
Verified
Journal Article
Open access
PDF file
DJDany Jaffuel
Dany Jaffuel
CRClaudio Rabec
Claudio Rabec
CPCarole Philippe
Carole Philippe
JMJEAN PIERRE MALLET
JEAN PIERRE MALLET
MGMarjolaine Georges
Marjolaine Georges
ABArnaud Bourdin
Arnaud Bourdin
Backgrounds: To explain the excess cardiovascular mortality observed in the SERVE-HF study, it was hypothesized that the high-pressure ASV default settings used lead to inappropriate ventilation, cascading negative consequences (i.e. not only pro-arrythmogenic effects through metabolic/electrolyte abnormalities, but also lower cardiac output). The aims of this study are: i) to describe ASV-settings for long-term ASV-populations in real-life conditions; ii) to describe the associated minute-ventilations (MV) and therapeutic pressures for servo-controlled-flow versus servo-controlled-volume devices (ASV-F Philips®-devices versus ASV-V ResMed®-devices). Methods: The OTRLASV-study is a cross-sectional, 5-centre study including patients who underwent ASV-treatment for at least 1 year. The eight participating clinicians were free to adjust ASV settings, which were compared among i) initial diagnosed sleep-disordered-breathing (SBD) groups (Obstructive-Sleep-Apnea (OSA), Central-Sleep-Apnea (CSA), Treatment-Emergent-Central-Sleep-Apnea (TECSA)), and ii) unsupervised groups (k-means clusters). To generate these clusters, baseline and follow-up variables were used (age, sex, body mass index (BMI), initial diagnosed Obstructive-Apnea-Index, initial diagnosed Central-Apnea-Index, Continuous-Positive-Airway-Pressure used before ASV treatment, presence of cardiopathy, and presence of a reduced left-ventricular-ejection-fraction (LVEF)). ASV-data were collected using the manufacturer’s software for 6 months. Results: One hundred seventy-seven patients (87.57% male) were analysed with a median (IQ25–75) initial Apnea-Hypopnea-Index of 50 (38–62)/h, an ASV-treatment duration of 2.88 (1.76–4.96) years, 61.58% treated with an ASV-V. SDB groups did not differ in ASV settings, MV or therapeutic pressures. In contrast, the five generated k-means clusters did (generally described as follows: (C1) male-TECSA-cardiopathy, (C2) male-mostly-CSA-cardiopathy, (C3) male-mostly-TECSA-no cardiopathy, (C4) female-mostly-elevated BMI-TECSA-cardiopathy, (C5) male-mostly-OSA-low-LVEF). Of note, the male-mostly-OSA-low-LVEF-cluster-5 had significantly lower fixed end-expiratory-airway-pressure (EPAP) settings versus C1 (p = 0.029) and C4 (p = 0.007). Auto-EPAP usage was higher in the male-mostly-TECSA-no cardiopathy-cluster-3 versus C1 (p = 0.006) and C2 (p < 0.001). MV differences between ASV-F (p = 0.002) and ASV-V (p < 0.001) were not homogenously distributed across clusters, suggesting specific cluster and ASV-algorithm interactions. Individual ASV-data suggest that the hyperventilation risk is not related to the cluster nor the ASV-monitoring type. Conclusions: Real-life ASV settings are associated with combinations of baseline and follow-up variables wherein cardiological variables remain clinically meaningful. At the patient level, a hyperventilation risk exists regardless of cluster or ASV-monitoring type, spotlighting a future role of MV-telemonitoring in the interest of patient-safety. Trial registration: The OTRLASV study was registered on ClinicalTrials.gov (Identifier: NCT02429986). 1 April 2015.

6 September 2024 in Respiratory Research
Verified
Journal Article
Open access
PDF file
CVCelia Vidal
Celia Vidal
FBFanny Bertelli
Fanny Bertelli
JMJEAN PIERRE MALLET
JEAN PIERRE MALLET
RGRaphael Gilson
Raphael Gilson
JBJean-Christian Borel
Jean-Christian Borel
DJDany Jaffuel
Dany Jaffuel
Over the past three decades, our understanding of sleep apnea in women has advanced, revealing disparities in pathophysiology, diagnosis, and treatment compared to men. However, no real-life study to date has explored the relationship between mask-related side effects (MRSEs) and gender in the context of long-term CPAP. The InterfaceVent-CPAP study is a prospective real-life cross-sectional study conducted in an apneic adult cohort undergoing at least 3 months of CPAP with unrestricted mask-access (34 different masks, no gender specific mask series). MRSE were assessed by the patient using visual analog scales (VAS). CPAP-non-adherence was defined as a mean CPAP-usage of less than 4 h per day. The primary objective of this ancillary study was to investigate the impact of gender on the prevalence of MRSEs reported by the patient. Secondary analyses assessed the impact of MRSEs on CPAP-usage and CPAP-non-adherence depending on the gender. A total of 1484 patients treated for a median duration of 4.4 years (IQ25–75: 2.0–9.7) were included in the cohort, with women accounting for 27.8%. The prevalence of patient-reported mask injury, defined as a VAS score ≥ 5 (p = 0.021), was higher in women than in men (9.6% versus 5.3%). For nasal pillow masks, the median MRSE VAS score for dry mouth was higher in women (p = 0.039). For oronasal masks, the median MRSE VAS score for runny nose was higher in men (p = 0.039). Multivariable regression analyses revealed that, for both women and men, dry mouth was independently and negatively associated with CPAP-usage, and positively associated with CPAP-non-adherence. In real-life patients treated with long-term CPAP, there are gender differences in patient reported MRSEs. In the context of personalized medicine, these results suggest that the design of future masks should consider these gender differences if masks specifically for women are developed. However, only dry mouth, a side effect not related to mask design, impacts CPAP-usage and non-adherence.

12 July 2025 in Respiratory Research
Verified
Journal Article
Open access
PDF file
CVCelia Vidal
Celia Vidal
JMJEAN PIERRE MALLET
JEAN PIERRE MALLET
SSSarah Skinner
Sarah Skinner
RGRaphael Gilson
Raphael Gilson
OGOlivier Gaubert
Olivier Gaubert
DJDany Jaffuel
Dany Jaffuel
Continuous Positive Airway Pressure (CPAP) telemonitoring is increasingly important in managing obstructive sleep apnea (OSA). The Apnea-Hypopnea Index reported by CPAP devices (AHIflow) is used as a key indicator of treatment effectiveness. However, discrepancies in AHIflow calculation rules between manufacturers may affect clinical decision-making. No prior studies have investigated whether manufacturers’ choices to exclude certain apnea-hypopnea events from the AHIflow calculation may influence the number of patients presenting an AHIflow alert. The aim of this proof-of-concept study was not to compare the manufacturers with each other, but to evaluate, for each manufacturer, how the different possible ways of calculating AHIflow influence the percentage of alert cases. We conducted a retrospective analysis of 13,764 CPAP-treated OSA patients monitored on October 2, 2023. AHIflow calculations were evaluated according to manufacturer-specific rules. When possible, we assessed the impact of excluding central hypopneas, events during major leaks, and/or ramp periods on the percentage of patients crossing the consensual AHIflow alert threshold of ≥ 10 events/h. We identified significant disparities in AHIflow calculations between manufacturers, which lead to significant differences in the number of patients flagged as being in an alert state. Excluding central hypopneas reduced the number of alert cases by 50%, while excluding apneas/hypopneas during major leaks or ramp periods reduced alerts by 20%. Our proof-of-concept study highlights inconsistencies in AHIflow calculations among CPAP manufacturers, raising concerns about patient care. Establishing standardized AHIflow calculation criteria is essential to ensuring accurate monitoring and optimal patient safety.