Alireza Jabbarinick

Mr. Alireza Jabbarinick

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
Nima RahmatiNima Rahmati
Nima Rahmati
HPHamid Pouraliakbar
Hamid Pouraliakbar
AEArshia Eskandari
Arshia Eskandari
KJKian Javari
Kian Javari
AJAlireza Jabbarinick
Alireza Jabbarinick
MAMona Alimohammadi
Mona Alimohammadi
The common iliac artery supplies blood to the lower extremities, and stenosis in this region severely impacts hemodynamics. This study investigates the effects of 25%, 50%, and 75% iliac artery stenosis on key hemodynamic parameters using a fluid–structure interaction (FSI) approach. Semi-idealized geometries reconstructed from patient-specific data modeled realistic arterial behavior. Parameters such as wall displacement, time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), high oscillatory low shear magnitude (HOLMES) index, and endothelial cell activation potential (ECAP) were evaluated. Results showed peak wall displacement of 2.85 mm in the bifurcation zone under 75% stenosis. TAWSS increased with stenosis severity, peaking in stenotic regions and decreasing significantly downstream. OSI was highest in non-stenosed right branches and bifurcation areas, indicating multidirectional shear forces. HOLMES values were lowest downstream of stenoses, indicating disturbed flow. ECAP exceeded the thrombosis risk threshold (1.4 Pa−1) in post-stenotic zones under 75% stenosis, suggesting a higher risk of clot formation. These results demonstrate that stenosis disrupts local flow and causes hemodynamic changes downstream, emphasizing the need for comprehensive clinical assessment beyond the stenotic site. Regions with elevated ECAP and low HOLMES downstream may be prone to thrombosis, highlighting the importance of careful hemodynamic monitoring for treatment strategies.

13 August 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AJAlireza Jabbarinick
Alireza Jabbarinick
MVMohammadebrahim Varan
Mohammadebrahim Varan
HPHamid Pouraliakbar
Hamid Pouraliakbar
Nima RahmatiNima Rahmati
Nima Rahmati
RDRezvan Dadras
Rezvan Dadras
PSParham Sadeghipour
Parham Sadeghipour
Background/Objectives: Blunt thoracic aortic injury (BTAI) is a rare, highly lethal trauma typically occurring at the aortic isthmus. Advanced BTAI is primarily treated with thoracic endovascular aortic repair (TEVAR). Because emergent surgical debranching is rarely feasible, management depends heavily on patient anatomy, especially regarding the left subclavian artery (LSA). Patient-specific computational fluid dynamics (CFD) models offer critical insights into periprocedural planning and outcome prediction. Methods: This study investigates hemodynamic changes in a patient-specific BTAI case following intentional LSA coverage by a stent graft. Three-dimensional patient-specific models were coupled with RCR-Windkessel boundary conditions for both pre- and post-procedural imaging data to simulate blood flow in each scenario. Results: Post-intervention, flow distribution improved significantly; relative perfusion to the brachiocephalic trunk and left common carotid artery increased by 3.51% and 4.02%, respectively, alongside an elevated overall pressure throughout the entire computational domain. However, regions with high oscillatory, low magnitude shear (HOLMES), specifically wall areas with values < 0.3 Pa, expanded post-stenting. This warrants careful monitoring during follow-ups, given the associated risk of thrombus formation. Furthermore, time-averaged swirling strength (TASS) variation along the aorta decreased (standard deviation dropped from 1.8610 to 1.3835), indicating stabilized flow within the stented region, while normalized swirling strength increased distally. Conclusions: This study establishes an effective, non-invasive framework for assessing pre- and post-TEVAR hemodynamics. It demonstrates that LSA coverage induces uniformly elevated pressure and alters wall shear stress and helicity indices, highlighting the need for future research into pharmacological management to optimize long-term outcomes.