21 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PEPedro Angel Blasco Espinosa
Pedro Angel Blasco Espinosa
RMRafael Montoya-Mira
Rafael Montoya-Mira
JAJosé Manuel Diez Aznar
José Manuel Diez Aznar
RVRafael Montoya Villena
Rafael Montoya Villena
MRMiguel J. Reig
Miguel J. Reig
The compensation of an electrical system from passive compensators mainly focuses on linear systems where the consumption of charges does not vary significantly over time. In three-phase three-wire systems, when the network voltages are unbalanced, negative-sequence voltages and currents appear, which can significantly increase the total apparent power supplied by the network. This also increases the network losses. This paper presents a method for calculating the compensation of the positive-sequence reactive power and unbalanced powers caused by the negative-sequence line currents using reactive elements (coils and/or capacitors). The compensation is applied to three-phase three-wire linear systems with unbalanced voltages and loads, which are connected to an infinite power network. The method is independent of the load characteristics, where only the line-to-line voltages and line currents, at the point where compensation is desired, need to be known in advance. The solution obtained is optimal, and the system observed from the network behaves as one that only consumes the active power required by a load with a fully balanced current system. To understand the proposed method and demonstrate its validity, a case study of a three-phase three-wire linear system connected to an infinite power network with unbalanced voltages and currents is conducted.

4 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RMRafael Montoya-Mira
Rafael Montoya-Mira
PEPedro Angel Blasco Espinosa
Pedro Angel Blasco Espinosa
JAJosé Manuel Diez Aznar
José Manuel Diez Aznar
RVRafael Montoya Villena
Rafael Montoya Villena
MRMiguel J. Reig
Miguel J. Reig
In an unbalanced linear three-phase electrical system, there are inefficient powers that increase the apparent power supplied by the network, line losses, machine malfunctions, etc. These inefficiencies are mainly due to the use of unbalanced loads. Unlike a three-wire unbalanced system, a four-wire system has zero sequence currents that circulate through the neutral wire and can be compensated by means of compensation equipment, which prevents it from being delivered by the network. To design a compensator that works with unbalanced voltages, it is necessary to consider the interactions between it and the other compensators used to compensate for negative-sequence currents and positive-sequence reactive currents. In this paper, through passive compensation, a new method is proposed to develop the zero sequence current compensation equipment. The method does not require iteration algorithms and is valid for unbalanced voltages. In addition, the interactions between all compensators are analyzed, and the necessary modifications in the calculations are proposed to obtain a total compensation. To facilitate the application of the method and demonstrate its validity, a case study is developed from a three-phase linear four-wire system with unbalanced voltages and loads. The results obtained are compared with other compensation methods that also use passive elements.

3 November 2023 in Electric Power Systems Research
Verified
Journal Article
Open access
PBPedro A. Blasco
Pedro A. Blasco
RMRafael Montoya-Mira
Rafael Montoya-Mira
JAJosé Manuel Diez Aznar
José Manuel Diez Aznar
RMRafael Montoya
Rafael Montoya

28 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PEPedro Angel Blasco Espinosa
Pedro Angel Blasco Espinosa
RMRafael Montoya-Mira
Rafael Montoya-Mira
JAJosé Manuel Diez Aznar
José Manuel Diez Aznar
RVRafael Montoya Villena
Rafael Montoya Villena
Low-voltage distribution systems are typically unbalanced. These inefficiencies cause unbalanced powers that can significantly increase the apparent power of the system. Analysing and measuring these inefficient powers appropriately allows us to compensate for them and obtain a more efficient system. Correcting the imbalance at some nodes can worsen the rest of the system; therefore, it is essential that all nodes are analysed such that action can be taken when necessary. In most studies, the unbalanced power is measured from the modulus. Other more recent studies have proposed phasor expressions of unbalanced powers; however, in both cases, these are not enough to address the compensation of unbalanced powers in systems with unbalanced voltages. In this work, a different representation of the vector expressions for analysis of the unbalanced powers and the apparent powers of the three-phase linear systems is proposed. Additionally, these vector expressions are extended to nonlinear systems to quantify the harmonic apparent powers. These expressions have been formulated from the power of Buchholz and are valid for systems with unbalanced voltages and currents. To help understand the use of the proposed formulation, a practical case of a three-phase four-wire system with unbalanced loads and voltages is demonstrated.

24 December 2021 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
PEPedro Angel Blasco Espinosa
Pedro Angel Blasco Espinosa
RMRafael Montoya‐Mira
Rafael Montoya‐Mira
JAJosé Manuel Diez Aznar
José Manuel Diez Aznar
RVRafael Montoya Villena
Rafael Montoya Villena
GGGabriel Garcerá
Gabriel Garcerá
EFEmilio Figueres
Emilio Figueres
Recent low‐voltage, three‐phase distribution networks carry inefficient power, which can be attributed to the reactive power, imbalance of linear loads, and increase in non‐linear loads. Researchers have mainly focused on developing active filters to improve the quality of electrical energy. However, in most cases, compensating for the reactive power is sufficient, considering cost and quality. Active filters are expensive, thus, passive compensators are more appealing. These devices are composed of single‐phase or three‐phase capacitor banks that act on the reactive power consumed by the load. The operation of these devices has been sufficiently validated owing to their long‐term use. For unbalanced power, compensators that contain coils are used. A methodology to obtain compensators comprising only single‐phase capacitors for the inductive reactive power consumed by the load is presented here; if designed appropriately, these compensators can compensate for a part of or the entire unbalanced power, resulting in greater efficiency in the transfer of electrical energy.

5 February 2018 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
RMRafael Montoya‐Mira
Rafael Montoya‐Mira
JAJosé Manuel Diez Aznar
José Manuel Diez Aznar
PEPedro Angel Blasco Espinosa
Pedro Angel Blasco Espinosa
RMRafael Montoya
Rafael Montoya
For analysis of three‐wire three‐phase linear systems, the transformations wye‐delta and delta‐wye from theorem of Kennelly are used. These transformations can be applied to balanced systems but not to unbalanced systems. This is due to the fact that zero‐sequence voltages or zero‐sequence currents are present in these types of connections. This modifies the value of the unbalance power in the load with respect to the generator. These zero‐sequence voltages and currents that appear in generators and loads are not transferred over the network. The zero‐sequence voltage in a delta‐connected load and the zero‐sequence current that is obtained using theorem of Kennelly in a star‐connected load, or vice versa, cause different imbalance effects. Here, the equivalent circuit for any point of the system is developed. The impedances of the equivalent circuit in any node are calculated using line‐to‐line voltages and line currents. This equivalent circuit incorporates all energetic phenomena, including the unbalance of all downstream loads. For its verification, the phasor unbalance power is used.