Guowei Liang

Dr. Guowei Liang


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2021 in Journal of Surgical Oncology
Verified
Journal Article
Closed access
PDF file
MBMingjian Bai
Mingjian Bai
SWShilong Wang
Shilong Wang
RMRuiqing Ma
Ruiqing Ma
YCYing Cai
Ying Cai
YLYiyan Lu
Yiyan Lu
MZMan Zhang
Man Zhang

6 December 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MBMingjian Bai
Mingjian Bai
JCJingliang Chen
Jingliang Chen
YXYueming Xu
Yueming Xu
JFJing Feng
Jing Feng
RMRuiqing Ma
Ruiqing Ma
HWHongjiang Wei
Hongjiang Wei
Peritoneal cancer index (PCI) is the surgical variable most commonly used to quantify the extent of peritoneal metastases for pseudomyxoma peritonei (PMP) patients. The present study aimed to investigate the agreement between CT predicted and surgical PCI by the Bland–Altman method for PMP of appendiceal origin. A total of 167 PMP patients of appendiceal origin were included between 2016 and 2021. Bland–Altman analysis was performed for both total PCI and selected PCI (regions 2 + 9–12). After the Bland–Altman plot was drawn, the mean bias and its 95% limit of agreements (LoAs) was quantified. Besides, the correlation coefficients between CT-PCI and surgical PCI were also been calculated. The Bland–Altman plot showed the mean bias ± SD between total CT-PCI and surgical PCI as 0.431 ± 3.005, with the LoAs from − 5.459 to 6.321. There were nine points of difference in total PCI exceeded the 95% LoAs, with the rate of 5.39% (9/167). As for selected CT-PCI, Bland–Altman plot showed the mean bias ± SD between selected CT-PCI and surgical PCI as − 0.287 ± 1.955, with the LoAs from − 4.118 to 3.544. There were ten points of difference in selected PCI exceeded the 95% LoAs, with the rate of 5.99% (10/167). The Spearman's rank correlation coefficient between total CT-PCI and surgical PCI was 0.911, P < 0.001, as for selected CT-PCI and surgical PCI, the coefficient was 0.909, P < 0.001. Although there was a strong correlation for both total and selected CT-PCI with surgical PCI, however, the agreement is still not good in Bland–Altman analysis, which suggested that CT-PCI cannot predict surgical PCI accurately even in professional PMP treatment centers. In brief explanation, CT makes it difficult to distinguish the borderline between tumor tissue and mucus and to detect tumor lesions in the small intestine regions, which caused overestimation or underestimation by CT-PCI. In the future, a multiple linear regression model based on CT-PCI might accurately predict surgical PCI preoperatively.

20 September 2018 in Chinese Medical Sciences Journal
Verified
Journal Article
Open access
PDF file
BMBai Mingjian
Bai Mingjian
FJFeng Jing
Feng Jing
GLGuowei Liang
Guowei Liang
Objective To determine whether urinary myeloperoxidase to creatinine ratio (MCR) can serve as a marker for diagnosis of urinary tract infection (UTI).Methods Patients suspected of UTI were consecutively enrolled and further divided into the culture positive and the sterile groups according to urine culture results. Subsequently, MCR, white blood cell (WBC) and bacteria in the urinary samples from patients were detected and compared between the two groups.Results Finally, 253 patients were enrolled including 157 urine culture positive patients and 96 urine culture negative patients (sterile group). After logarithmic transformation in 2 as the base, the MCR, WBC, and bacteria were separately presented as log2 MCR, log2 WBC(quantitative) , and log2 bacteria. The values of log2 MCR(8.6±2.5 vs. 5.4±1.5, t=-12.453, P=0.001), log2 WBC(quantitative) (8.0±2.5 vs. 5.2±1.8, t=-10.332, P=0.001), log2 bacteria (11.4±2.5 vs. 8.2±2.8, t=-9.297, P=0.001) and WBC (semi-quantitative) [2 (interquartile range 1, 3) vs. 1 (interquartile range 0.5, 1), Z=-7.580, P=0.001] showed significant difference between the urine culture positive group and the sterile group. Among the urine culture positive group, the values of log2 MCR of the gram positive and gram negative subgroups were 7.2±2.5 and 9.0±2.4 (t=4.016, P=0.001), respectively. The correlation between log2 MCR and log2 WBC (quantitative), log2 bacteria, WBC (semi-quantitative) was 0.708 (Pearson correlation, P=0.001), 0.381 (Pearson correlation, P=0.001), and 0.606 (Spearman correlation, P=0.001), respectively. Conclusions MCR is positively correlated with WBC counts and could be served as a promising biomarker for diagnosis of UTI. MCR could be even used for initial inference of infectious bacteria types of UTI.

5 September 2025 in Frontiers in Public Health
Verified
Journal Article
Open access
PDF file
MBMingjian Bai
Mingjian Bai
YLYunxiang Li
Yunxiang Li
FMFucun Ma
Fucun Ma
QGQian Gao
Qian Gao
ZLZhiyong Lv
Zhiyong Lv
GLGuowei Liang
Guowei Liang
Background: The present study aimed to assess the prevalence and genotype distribution of Human papillomavirus (HPV) in Beijing females.Methods: A total of 73,697 subjects [both Department of Gynecology (n = 35,666) and Physical Examination center (n = 38,031)] were retrieved between June 2014 and December 2023. HPV testing was performed by Tellgenplex® HPV-27 DNA genotyping Test system.Results: An overall HPV infection rate of 17.28% (12,736/73,697) over the past decade (2014 to 2023), with a significant decrease in annual incidence (p < 0.001). HPV-52, 16, and 58 were predominant in high-risk types, while HPV-61, 81, and 43 were the most prevalent in low-risk HPV types. Age-specific patterns revealed bimodal infection peaks in individuals under 21 and between 51 ~ 56 years. Furthermore, a significant increase in HPV infection rates was observed with the progression of pathological severity (p < 0.001).Conclusion: This study emphasizes the importance of HPV infection rate from real word and developing vaccines specifically for the Chinese population. In the future, it is necessary to design more suitable vaccines based on Chinese HPV type ranking, especially for HR-HPV (HPV-39, HPV-53, and HPV-56) and LR-HPV (HPV-43, HPV-61, and HPV-81).

1 January 2018 in Clinical Laboratory
Verified
Journal Article
Closed access
MBMingjian Bai
Mingjian Bai
JFJing Feng
Jing Feng
GLGuowei Liang
Guowei Liang
Antiphospholipid syndrome (APS) is an autoimmune disorder associated with arterial/venous thrombosis and pregnancy loss; thrombocytopenia is another common manifestation of APS. In the present study, we discovered a transient ethylenediaminetetraacetic acid-dependent pseudothrombocytopenia (EDTA-PTCP) phenomenon in APS, which has not yet been reported in the literature.

12 November 2025 in Virology Journal
Verified
Journal Article
Open access
PDF file
MBMingjian Bai
Mingjian Bai
YLYunxiang Li
Yunxiang Li
QGQian Gao
Qian Gao
ZLZhiyong Lv
Zhiyong Lv
FFFengxian Fu
Fengxian Fu
JFJing Feng
Jing Feng
Purpose: Present study aimed to compare the boiling and magnetic bead nucleic acid extraction method for HPV genotypes detection. Methods: By mixing hemoglobin with HPV positive quality control products, the anti-interference ability of two nucleic acid extraction methods on hemoglobin was simulated. Subsequently, on the basis of paired small sample and longitudinal large sample comparisons, the HPV detection rates between the boiling and magnetic bead-based method were evaluated. Finally, the cost-benefit comparisons of the two extraction methods were further evaluated. A two-sided P value of less than 0.05 was considered statistically significant. Results: As for boiling method, when the hemoglobin concentration exceeded 30 g/L, HPV positive control could not be detected, nevertheless, the HPV positive control can still be detected even when the hemoglobin concentration reached 60 g/L for magnetic bead method. In the paired small-scale (639 cases) experiment, results indicated that the positive detection rate of HPV using the magnetic bead method was significantly higher than that of the boiling method, with positive rates of 20.66% and 10.02% ( P < 0.001), respectively. Additionally, in the longitudinal large-scale analysis (16540 cases) reached the same conclusion. Compared with boiling method, the cost of magnetic bead method increased by 13.14%, however, the detection rate of HPV increased by 106.19%. Conclusion: Compared to the boiling method, the magnetic bead-based nucleic acid extraction technique exhibited superior anti-interference capabilities and a significant higher detection rate for HPV. Furthermore, it is highly cost-effective. It is anticipated that the magnetic bead method will be fully adopted for HPV detection in place of the boiling method in the future. Of course, more research is needed to verify this conclusion.