Johannes Bernarding

Prof. Dr. Johannes Bernarding

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KBKai Buckenmaier
Kai Buckenmaier
MRM. Rudolph
M. Rudolph
CBC. Back
C. Back
TMT. Misztal
T. Misztal
UBU. Bommerich
U. Bommerich
MPM. Plaumann
M. Plaumann
Ultra-low-field (ULF) nuclear magnetic resonance (NMR) is a promising spectroscopy method allowing for, e.g., the simultaneous detection of multiple nuclei. To overcome the low signal-to-noise ratio that usually hampers a wider application, we present here an alternative approach to ULF NMR, which makes use of the hyperpolarizing technique signal amplification by reversible exchange (SABRE). In contrast to standard parahydrogen hyperpolarization, SABRE can continuously hyperpolarize 1 H as well as other MR-active nuclei. For simultaneous measurements of 1 H and 19 F under SABRE conditions a superconducting quantum interference device (SQUID)-based NMR detection unit was adapted. We successfully hyperpolarized fluorinated pyridine derivatives with an up to 2000-fold signal enhancement in 19 F. The detected signals may be explained by two alternative reaction mechanisms. SABRE combined with simultaneous SQUID-based broadband multinuclear detection may enable the quantitative analysis of multinuclear processes.

26 May 2010 in Experimental Brain Research
Verified
Journal Article
Open access
PDF file
MLMichael Luchtmann
Michael Luchtmann
KJK. Jachau
K. Jachau
CTC. Tempelmann
C. Tempelmann
JBJohannes Bernarding
Johannes Bernarding
Worldwide, ethanol abuse causes thousands of fatal accidents annually as well as innumerable social dysfunctions and severe medical disorders. Yet, few studies have used the blood oxygenation level dependent functional magnetic resonance imaging method (BOLD fMRI) to map how alcohol alters brain functions, as fMRI relies on neurovascular coupling, which may change due to the vasoactive properties of alcohol. We monitored the hemodynamic response function (HRF) with a high temporal resolution. In both motor cortices and the visual cortex, alcohol prolonged the time course of the HRF, indicating an overall slow-down of neurovascular coupling rather than an isolated reduction in neuronal activity. However, in the supplementary motor area, alcohol-induced changes to the HRF suggest a reduced neuronal activation. This may explain why initiating and coordinating complex movements, including speech production, are often impaired earlier than executing basic motor patterns. Furthermore, the present study revealed a potential pitfall associated with the statistical interpretation of pharmacological fMRI studies based on the general linear model: if the functional form of the HRF is changed between the conditions data may be erroneously interpreted as increased or decreased neuronal activation. Thus, our study not only presents an additional key to how alcohol affects the network of brain functions but also implies that potential changes to neurovascular coupling have to be taken into account when interpreting BOLD fMRI. Therefore, measuring individual drug-induced HRF changes is recommended for pharmacological fMRI.

13 July 2018 in Chemphyschem
Verified
Journal Article
Open access
PDF file
JBJohannes Bernarding
Johannes Bernarding
FEFrederike Euchner
Frederike Euchner
CBChristian Bruns
Christian Bruns
RRRainer Ringleb
Rainer Ringleb
DMDarius Müller
Darius Müller
MPMarkus Plaumann
Markus Plaumann
Substrates containing 19F can serve as background‐free reporter molecules for NMR and MRI. However, in vivo applications are still limited due to the lower signal‐to‐noise ratio (SNR) when compared with 1H NMR. Although hyperpolarization can increase the SNR, to date, only photo‐chemically induced dynamic nuclear polarization (photo‐CIDNP) allows for hyperpolarization without harmful metal catalysts. Photo‐CIDNP was shown to significantly enhance 19F NMR signals of 3‐fluoro‐DL‐tyrosine in aqueous solution using flavins as photosensitizers. However, lasers were used for photoexcitation, which is expensive and requires appropriate protection procedures in a medical or lab environment. Herein, we report 19F MR hyperpolarization at 4.7 T and 7 T with a biocompatible system using a low‐cost and easy‐to‐handle LED‐based set‐up. First hyperpolarized 19F MR images could be acquired, because photo‐CIDNP enabled repetitive hyperpolarization without adding new substrates.

19 September 2019 in Chemphyschem
Verified
Journal Article
Open access
PDF file
KBKai Buckenmaier
Kai Buckenmaier
KSKlaus Scheffler
Klaus Scheffler
MPMarkus Plaumann
Markus Plaumann
PFPaul Fehling
Paul Fehling
JBJohannes Bernarding
Johannes Bernarding
APAndrey N. Pravdivtsev
Andrey N. Pravdivtsev
The development of hyperpolarization technologies enabled several yet exotic NMR applications at low and ultra‐low fields (ULF), where without hyperpolarization even the detection of a signal from analytes is a challenge. Herein, we present a method for the simultaneous excitation and observation of homo‐ and heteronuclear multiple quantum coherences (from zero up to the third‐order), which give an additional degree of freedom for ULF NMR experiments, where the chemical shift variation is negligible. The approach is based on heteronuclear correlated spectroscopy (COSY); its combination with a phase‐cycling scheme allows the selective observation of multiple quantum coherences of different orders. The nonequilibrium spin state and multiple spin orders are generated by signal amplification by reversible exchange (SABRE) and detected at ULF with a superconducting quantum interference device (SQUID)‐based NMR system.

14 June 2017 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
IEIbrahim A. Elabyad
Ibrahim A. Elabyad
THTim Herrmann
Tim Herrmann
CBChristian Bruns
Christian Bruns
JBJohannes Bernarding
Johannes Bernarding
DEDaniel Erni
Daniel Erni
A remote transmission and detection for magnetic resonance imaging (MRI) at 7 T was validated by using a patch antenna that excites the traveling-wave (TW) modes guided by the radio frequency (RF) shield of the MRI system. In this paper, RF simulations were performed at 298 MHz for an eight-element stepped impedance resonators (SIRs) head volume coil combined with a patch antenna. The combined structure is loaded with both a cylindrical phantom and the Duke full-body human voxel model. An optimization routine was developed in MATLAB to provide homogenous B1+ field distributions with minimal 10 g averaged specific absorption rate (SAR) values within the phantom and the Duke human biological model. Before optimization, the TW approach achieved a more homogenous B1+ field distribution providing a large field of view along the propagation direction compared to the SIRs head volume coil. However, the corresponding peak local SAR values for the TW approach is about 2.4 times higher than those of the SIRs head volume coil. The B1+ transmission efficiency for the TW approach is higher than that of the SIRs head volume coil by 10-30% due to the coupling of the TW modes into the volume coil. The RF-shimming technique improves the B1+ field homogeneity for the combined approach by 42%, 48%, and 47% in the central axial, sagittal, and coronal slices, respectively, and satisfies the constraints of maximum local SAR in the human head for MRI at 7 T.

14 September 2015 in Frontiers in Systems Neuroscience
Verified
Journal Article
Open access
PDF file
JMJohannes Mallow
Johannes Mallow
JBJohannes Bernarding
Johannes Bernarding
MLMichael Luchtmann
Michael Luchtmann
ABAnja Bethmann
Anja Bethmann
ABAndré Brechmann
André Brechmann
Superior memorizers often employ the method of loci (MoL) to memorize large amounts of information. The method of loci, known since ancient times, relies on a complex process where information to be memorized is bound to landmarks along mental routes in a previously memorized environment. However, fMRI data on groups of trained superior memorizer are rare. Based on the memorizing strategy reported by superior memorizers we developed a scheme of the processes successively employed during memorizing and recalling digits and relate these to brain activation that is specific for the encoding and recall period. In the examined superior memorizers several regions, suggested to be involved in mental navigation and digit-to-word processing, were specifically activated during encoding: bilateral early visual cortex, retrosplenial cortex, left parahippocampus, left visual cortex, and left superior parietal cortex. Although the scheme suggests that some steps during encoding and recall seem to be analog, none of the encoding areas were specifically activated during the recall. Instead, we found strong activation in left anterior superior temporal gyrus, which we relate to recalling the sequential order of the digits, and right motor cortex that may be related to reciting the digits.