Hannaneh Hojaiji

Ms. Hannaneh Hojaiji

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2022 in Science Advances
Verified
Journal Article
Open access
BWBo Wang
Bo Wang
CZChuanzhen Zhao
Chuanzhen Zhao
ZWZhaoqing Wang
Zhaoqing Wang
KYKyung-Ae Yang
Kyung-Ae Yang
XCXuanbing Cheng
Xuanbing Cheng
SESam Emaminejad
Sam Emaminejad
A smartwatch was developed for noninvasive stress biomarker data acquisition that provides real-time feedback to the wearer.

2 September 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
HLHaisong Lin
Haisong Lin
JTJiawei Tan
Jiawei Tan
JZJialun Zhu
Jialun Zhu
SLShuyu Lin
Shuyu Lin
YZYichao Zhao
Yichao Zhao
SESam Emaminejad
Sam Emaminejad
Active biofluid management is central to the realization of wearable bioanalytical platforms that are poised to autonomously provide frequent, real-time, and accurate measures of biomarkers in epidermally-retrievable biofluids (e.g., sweat). Accordingly, here, a programmable epidermal microfluidic valving system is devised, which is capable of biofluid sampling, routing, and compartmentalization for biomarker analysis. At its core, the system is a network of individually-addressable microheater-controlled thermo-responsive hydrogel valves, augmented with a pressure regulation mechanism to accommodate pressure built-up, when interfacing sweat glands. The active biofluid control achieved by this system is harnessed to create unprecedented wearable bioanalytical capabilities at both the sensor level (decoupling the confounding influence of flow rate variability on sensor response) and the system level (facilitating context-based sensor selection/protection). Through integration with a wireless flexible printed circuit board and seamless bilateral communication with consumer electronics (e.g., smartwatch), contextually-relevant (scheduled/on-demand) on-body biomarker data acquisition/display was achieved.

20 March 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
YZYichao Zhao
Yichao Zhao
BWBo Wang
Bo Wang
HHHannaneh Hojaiji
Hannaneh Hojaiji
ZWZhaoqing Wang
Zhaoqing Wang
SLShuyu Lin
Shuyu Lin
SESam Emaminejad
Sam Emaminejad
We devised a strategy for high-fidelity, wearable biomarker data acquisition and sensor integration with consumer electronics.

27 July 2020 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
SLShuyu Lin
Shuyu Lin
WYWenzhuo Yu
Wenzhuo Yu
BWBo Wang
Bo Wang
YZYichao Zhao
Yichao Zhao
KEKe En
Ke En
SESam Emaminejad
Sam Emaminejad
To achieve the mission of personalized medicine, centering on delivering the right drug to the right patient at the right dose, therapeutic drug monitoring solutions are necessary. In that regard, wearable biosensing technologies, capable of tracking drug pharmacokinetics in noninvasively retrievable biofluids (e.g., sweat), play a critical role, because they can be deployed at a large scale to monitor the individuals’ drug transcourse profiles (semi)continuously and longitudinally. To this end, voltammetry-based sensing modalities are suitable, as in principle they can detect and quantify electroactive drugs on the basis of the target’s redox signature. However, the target’s redox signature in complex biofluid matrices can be confounded by the immediate biofouling effects and distorted/buried by the interfering voltammetric responses of endogenous electroactive species. Here, we devise a wearable voltammetric sensor development strategy—centering on engineering the molecule–surface interactions—to simultaneously mitigate biofouling and create an “undistorted potential window” within which the target drug’s voltammetric response is dominant and interference is eliminated. To inform its clinical utility, our strategy was adopted to track the temporal profile of circulating acetaminophen (a widely used analgesic and antipyretic) in saliva and sweat, using a surface-modified boron-doped diamond sensing interface (cross-validated with laboratory-based assays, R2 ∼ 0.94). Through integration of the engineered sensing interface within a custom-developed smartwatch, and augmentation with a dedicated analytical framework (for redox peak extraction), we realized a wearable solution to seamlessly render drug readouts with minute-level temporal resolution. Leveraging this solution, we demonstrated the pharmacokinetic correlation and significance of sweat readings. Significance To achieve the mission of personalized medicine, centering on delivering the right drug to the right patient at the right dose, therapeutic drug monitoring solutions are necessary. By devising a surface engineering strategy, we created a voltammetric sensing interface, featuring an “undistorted potential window,” within which the target electroactive drug’s voltammetric response is dominant and interference is eliminated, rendering reliable target quantification in noninvasively retrievable biofluids (sweat and saliva). Leveraging this sensing interface, a fully integrated, wearable solution was constructed to seamlessly render drug readouts with minute-level temporal resolution. To inform its clinical utility, the solution was utilized to demonstrate noninvasive pharmacokinetic monitoring of a pharmaceutical (here, acetaminophen, a widely used analgesic and antipyretic) in a wearable format.

1 December 2019 in ACS Sensors
Verified
Journal Article
Open access
SLShuyu Lin
Shuyu Lin
BWBo Wang
Bo Wang
YZYichao Zhao
Yichao Zhao
RSRyan Shih
Ryan Shih
XCXuanbing Cheng
Xuanbing Cheng
SESam Emaminejad
Sam Emaminejad
Recent advances in microelectronics, microfluidics, and electrochemical sensing platforms have enabled the development of an emerging class of fully integrated personal health monitoring devices that exploit sweat to noninvasively access biomarker information. Despite such advances, effective sweat sampling remains a significant challenge for reliable biomarker analysis, with many existing methods requiring active stimulation (e.g., iontophoresis, exercise, heat). Natural perspiration offers a suitable alternative as sweat can be collected with minimal effort on the part of the user. To leverage this phenomenon, we devised a thin hydrogel micropatch (THMP), which simultaneously serves as an interface for sweat sampling and a medium for electrochemical sensing. To characterize the performance of the THMP, caffeine and lactate were selected as two representative target molecules. We demonstrated the suitability of the sampling method to track metabolic patterns, as well as to render sample-to-answer biomarker data for personal monitoring (through coupling with an electrochemical sensing system). To inform its potential application, this biomarker sampling and sensing system is incorporated within a distributed terminal-based sensing network, which uniquely capitalizes on the fingertip as a site for simultaneous biomarker data sampling and user identification.

16 December 2019 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
XCXuanbing Cheng
Xuanbing Cheng
BWBo Wang
Bo Wang
YZYichao Zhao
Yichao Zhao
HHHannaneh Hojaiji
Hannaneh Hojaiji
SLShuyu Lin
Shuyu Lin
SESam Emaminejad
Sam Emaminejad