Based on a previously designed variable-stiffness load transfer component (LTC), a novel dispersed-tendon cable anchor system (CAS) was developed to increase the anchoring efficiency of large-diameter basalt-fiber-reinforced polymer (BFRP) cables. The static behaviors of the CAS are then numerically evaluated by a simplified three-dimensional finite-element (FE) model and implemented in a full-scale BFRP cable. The FE results indicated that the accuracy of the simplified dispersed-tendon model could be effectively ensured by dividing the revised compensation factor. The anchor behavior of the dispersed-tendon CAS was superior to that of the parallel-tendon CAS when the same cable was applied. The radial stress and tensile stress difference can be reduced by decreasing the tendon spacing. The testing and simulated results agreed well with the load–displacement relationship and axial displacement. All tendons fractured in the testing section, and the LTC suffered minimal damage. The ultimate force of the cable with 127 4-mm-diameter tendons was 2419 kN, and the corresponding anchoring efficiency was 93%. The cable axial tensile strain in the anchoring zone decreased linearly from the loading end to the free end. The cable shear stress concentration at the loading end can be avoided by employing a variable-stiffness anchoring method.
Transverse shear performance is the weakness of glass fiber-reinforced polypropylene (GFRPP) bars, and its long-term stability in marine environments is crucial to the safety and life of marine structures. This study systematically investigated the transverse shear behavior of GFRPP bars after exposure to distilled water (DW), seawater (SW), and an alkaline seawater sea-sand concrete pore solution (AS) at different temperatures (25, 40, 60°C) and durations (4, 8, 12 weeks), and conducts analysis of degradation mechanisms and service life prediction. The results indicate that the transverse shear strength (TSS) retention decreases with increasing temperature and exposure time, with the most significant degradation observed in AS. Elevated temperature has a threshold effect on accelerating degradation, as the rate increases sharply when exceeding 40 °C. A modified TSS retention prediction model with higher accuracy (R2>0.96) is proposed. The predicted service life was (TSS retention drops to 30%) 3154d, 1886d, 1413d in SW and 578d, 423d, 354d in AS at 5.7°C, 14°C, 23°C respectively. This study presents long-term transverse shear data and a service life prediction model for GFRPP bars, thereby providing data and theoretical support for their application in marine engineering.
19 May 2026 in Tunnelling and Underground Space Technology