Qiong chen, huixian Wang

Dr. Qiong chen, huixian Wang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2025 in Water
Verified
Journal Article
Open access
PDF file
QWQiong chen, huixian Wang
Qiong chen, huixian Wang
XYXiang Yu
Xiang Yu
TZTao Zhang
Tao Zhang
JDJiansen Du
Jiansen Du
HWHuixian Wu
Huixian Wu
For accurate and reliable monitoring, compliance monitoring devices (CMDs) in Port State Control must meet strict and uniform quality standards. This study evaluates how effectively CMDs, using variable fluorescence (VF) and fluorescein diacetate (FDA) technologies, detect live organisms in the 10–50 μm size range. Employing a detailed analytical framework, we analyzed key performance indicators, including accuracy, precision, sensitivity, specificity, trueness, detection limits, and reliability by comparing CMD outputs to those of traditional microscopic methods. Reliability assessments revealed that VF-type CMD and FDA-type CMD performed robustly, with a stability rate of 99% for both, surpassing the 90% verification threshold. Precision analysis indicated an average CV exceeding 0.25; however, some samples, especially those below the D-2 standard, achieved a CV of less than 0.25. Concordance evaluations revealed that VF-CMDs and FDA-CMDs achieved rates of 63% and 55%, respectively, falling short of the 80% verification standard and underscoring the need for further calibration or optimization. Structural equation modeling shows that organism density significantly influences CMD performance. These findings underscore the challenges of accurately detecting low organism concentrations, further complicated by biological diversity and environmental variability. Despite their limitations in assessing ballast water compliance, CMDs are effective initial screening tools.

Verified
Journal Article
Open access
PDF file
YLYouxia Lu
Youxia Lu
QWQiong chen, huixian Wang
Qiong chen, huixian Wang
LYLin Yuan
Lin Yuan
HWHuixian Wu
Huixian Wu
To address the risks of cross-border transmission of pathogenic microorganisms posed by the failure or non-compliance of shipboard ballast water treatment systems, ports urgently require efficient and flexible emergency response solutions. This study presents a novel, containerized, integrated ship-to-shore emergency response system specifically designed for the rapid inactivation of pathogenic microorganisms in ballast water. The core innovation lies in the integration of a three-degree-of-freedom (3-DOF) hydraulic robotic arm, a vision and positioning system, and a dynamic inflatable sealing structure designed for rapid, automated docking with a ship’s ballast water discharge outlet (DN250), thereby enhancing operational safety and efficiency. The system employs a purely physical treatment process of “ultrasound (US) pre-treatment + dual-stage ultraviolet (UV) disinfection,” allowing for reception and treatment without secondary chemical pollution. The integrated treatment train, consisting of US (30 kHz, 7.6–12 kW, minimum acoustic energy density ≥ 0.45 J/cm2) followed by dual-stage UV disinfection (minimum UV dose: 147 mJ/cm2), maintained effective microbial inactivation at turbidity levels of 15, 125, 250, and 500 NTU. US alone showed little direct bactericidal effect, whereas the first UV stage achieved log reduction values (LRVs) of 3.31–4.13, and the complete US + UV + UV process achieved total LRVs of 5.07–7.34 for Escherichia coli. The results showed that dual-stage UV disinfection was key to achieving high inactivation efficacy (p < 0.001), while ultrasound, despite its limited direct bactericidal effect, may have facilitated downstream UV disinfection within the sequential treatment train. This system not only fills a critical gap in port biosecurity emergency infrastructure but also provides an experimentally validated, efficient, environmentally friendly, and flexibly deployable shore-based solution.