Mahima Bansal

Ms. Mahima Bansal

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in Journal of Controlled Release
Verified
Journal Article
Closed access
RARaida Al-Kassas
Raida Al-Kassas
MBMahima Bansal
Mahima Bansal
JSJohn Shaw
John Shaw

1 December 2020 in Journal of Controlled Release
Verified
Journal Article
Closed access
MBMahima Bansal
Mahima Bansal
ADAnusha Dravid
Anusha Dravid
ZAZaid Aqrawe
Zaid Aqrawe
JMJohanna Montgomery
Johanna Montgomery
Zimei WuZimei Wu
Zimei Wu
DSDarren Svirskis
Darren Svirskis

1 January 2022 in Acta Biomaterialia
Verified
Journal Article
Closed access
MBMahima Bansal
Mahima Bansal
BRBrad Raos
Brad Raos
ZAZaid Aqrawe
Zaid Aqrawe
Zimei WuZimei Wu
Zimei Wu
DSDarren Svirskis
Darren Svirskis

11 January 2023 in Acta Biomaterialia
Verified
Journal Article
Open access
ECErnest Cheah
Ernest Cheah
MBMahima Bansal
Mahima Bansal
LNLinh Nguyen
Linh Nguyen
ACAnaïs Chalard
Anaïs Chalard
JMJenny Malmström
Jenny Malmström
DSDarren Svirskis
Darren Svirskis
Electrically modulated delivery of proteins provides an avenue to target local tissues specifically and tune the dose to the application. This approach prolongs and enhances activity at the target site whilst reducing off-target effects associated with systemic drug delivery. The work presented here explores an electrically active composite material comprising of a biocompatible hydrogel, gelatin methacryloyl (GelMA) and a conducting polymer, poly(3,4-ethylenedioxythiophene), generating a conducting polymer hydrogel. In this paper, the key characteristics of electroactivity, mechanical properties, and morphology are characterized using electrochemistry techniques, atomic force, and scanning electron microscopy. Cytocompatibility is established through exposure of human cells to the materials. By applying different electrical-stimuli, the short-term release profiles of a model protein can be controlled over 4 h, demonstrating tunable delivery patterns. This is followed by extended-release studies over 21 days which reveal a bimodal delivery mechanism influenced by both GelMA degradation and electrical stimulation events. This data demonstrates an electroactive and cytocompatible material suitable for the delivery of protein payloads over 3 weeks. This material is well suited for use as a treatment delivery platform in tissue engineering applications where targeted and spatio-temporal controlled delivery of therapeutic proteins is required. STATEMENT OF SIGNIFICANCE: Growth factor use in tissue engineering typically requires sustained and tunable delivery to generate optimal outcomes. While conducting polymer hydrogels (CPH) have been explored for the electrically responsive release of small bioactives, we report on a CPH capable of releasing a protein payload in response to electrical stimulus. The composite material combines the benefits of soft hydrogels acting as a drug reservoir and redox-active properties from the conducting polymer enabling electrical responsiveness. The CPH is able to sustain protein delivery over 3 weeks, with electrical stimulus used to modulate release. The described material is well suited as a treatment delivery platform to deliver large quantities of proteins in applications where spatio-temporal delivery patterns are paramount.

MBMahima Bansal
Mahima Bansal
MSManisha Sharma
Manisha Sharma
CBChristopher Bullen
Christopher Bullen
DSDarren Svirskis
Darren Svirskis
(1) Background: Despite the growing use of e-cigarettes, in most countries, there is no regulation covering manufacturing standards of the solution (‘e-liquid’), leading to concerns over the accuracy of labelling and stability of the products under a range of conditions. Following the United States (US) Food and Drug Administration (FDA) requirements for manufacture of e-liquids, we aimed to develop a simple high-performance liquid chromatography (HPLC) method to determine nicotine content in nicotine-containing e-liquids, even in the presence of degradation products; (2) Methods: We developed an HPLC method to quantify nicotine in the presence of the two major constituents of all e-liquids, glycerine and propylene glycol, and in the presence of degradation products; (3) Results: Our HPLC method performed strongly and was validated according to international guidelines. For the e-liquids tested, nicotine content levels were all higher than labelled (up to 117.9 ± 1.87% of the labelled content). While nicotine was shown to be unstable at 60 °C, it was stabilized at this temperature in the e-liquid formulations for up to 10 days; and (4) Conclusions: The HPLC method is suitable for adoption by laboratories to determine the actual content and stability of nicotine-containing products. The higher than labelled nicotine levels in e-liquids raises clinical and public health concerns.

20 August 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ZAZaid Aqrawe
Zaid Aqrawe
NPNitish Patel
Nitish Patel
YVYukti Vyas
Yukti Vyas
MBMahima Bansal
Mahima Bansal
JMJohanna Montgomery
Johanna Montgomery
DSDarren Svirskis
Darren Svirskis
In this paper, we aim to detail the setup of a high spatio-temporal resolution, electrical recording system utilising planar microelectrode arrays with simultaneous optical imaging suitable for evaluating microelectrode performance with a proposed ′performance factor′ metric. Techniques that would facilitate low noise electrical recordings were coupled with voltage sensitive dyes and neuronal activity was recorded both electrically via a customised amplification system and optically via a high speed CMOS camera. This technique was applied to characterise microelectrode recording performance of gold and poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) coated electrodes through traditional signal to noise (SNR) calculations as well as the proposed performance factor. Neuronal activity was simultaneously recorded using both electrical and optical techniques and this activity was confirmed via tetrodotoxin application to inhibit action potential firing. PEDOT/PSS outperformed gold using both measurements, however, the performance factor metric estimated a 3 fold improvement in signal transduction when compared to gold, whereas SNR estimated an 8 fold improvement when compared to gold. The design and functionality of a system to record from neurons both electrically, through microelectrode arrays, and optically via voltage sensitive dyes was successfully achieved. The high spatiotemporal resolution of both electrical and optical methods will allow for an array of applications such as improved detection of subthreshold synaptic events, validation of spike sorting algorithms and a provides a robust evaluation of extracellular microelectrode performance.