Arno Dentel

Prof. Dr. Arno Dentel

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2025 in Buildings
Verified
Journal Article
Open access
PDF file
SBSusanna Bordin
Susanna Bordin
RWRenate Weisboeck-Erdheim
Renate Weisboeck-Erdheim
SHSebastian Hummel
Sebastian Hummel
JGJonathan Griener
Jonathan Griener
AHArnulf Hartl
Arnulf Hartl
ADArno Dentel
Arno Dentel
Indoor environmental quality is essential for pupils‘ health, comfort, and academic performance. However, recent studies indicate that indoor air quality (IAQ) in classrooms is often inadequate. This observational study examines the impact of three ventilation concepts on IAQ and thermal comfort under real-life school conditions: manual window airing combined with CO2 traffic lights, decentralized mechanical ventilation, and centralized mechanical ventilation. Eight classrooms in three elementary schools were monitored from October 2023 to April 2024. Continuous long-term measurements covered CO2, PM2.5, VOCs, indoor air temperature, relative humidity and window opening states in the classrooms, and ambient data including PM2.5 at each school. Significant differences were found in all five indoor parameters across the three ventilation concepts. The decentralized ventilation group achieved the lowest CO2 concentrations (18–22% lower), while the window airing group showed the highest PM2.5 levels (mean of 6 µg/m3) and the lowest temperatures (21% of the time below 20 °C). Relative humidity tended to be too low for all concepts, particularly with mechanical ventilation (medians below 40%). Windows in the window airing group were opened approximately twice as long. The findings highlight the benefits of well-operated mechanical ventilation systems and underscore the importance of user awareness and system management.

3 January 2026 in Buildings
Verified
Journal Article
Open access
PDF file
SBSusanna Bordin
Susanna Bordin
RWRenate Weisboeck-Erdheim
Renate Weisboeck-Erdheim
SHSebastian Hummel
Sebastian Hummel
BFBarbara Fixl
Barbara Fixl
JGJonathan Griener
Jonathan Griener
AHArnulf Hartl
Arnulf Hartl
Effective classroom ventilation is essential for indoor environmental quality (IEQ), comfort and health of schoolchildren, who spend substantial time indoors. This controlled observational study compared manual window airing (WA) with decentralized mechanical ventilation (DV) in six classrooms of two elementary schools during the winter infection period. Symptoms of upper respiratory tract infections, salivary biomarkers, well-being, perceived comfort, and classroom-level IEQ were assessed through questionnaires, saliva samples and long-term monitoring. Ninety-eight schoolchildren participated (64 WA, 34 DV). Symptom-based outcomes of the WURSS-K questionnaire showed consistently lower illness burden in group DV, with several parameters reaching statistical significance and an absolute risk reduction of 7.8%. Salivary immunoglobulin A (sIgA) concentrations were also significantly lower in group DV (approximately 39–59%, p ≤ 0.01). Sensitivity analyses showed positive associations of CO2 and PM2.5 with sIgA and indicated that PM2.5 exposure accounted for group differences. Comfort perceptions mirrored measured IEQ: DV classrooms exhibited warmer, more stable thermal conditions, lower CO2 and PM2.5, and slightly better thermal and draught-related impressions. Overall, decentralized mechanical ventilation supported favorable IEQ and comfort and may influence mucosal immune activity through reduced particulate exposure, complementing the observed reduction in symptom burden. A multidimensional approach integrating medical outcomes with continuous IEQ monitoring proved valuable and should be expanded in larger, balanced cohort studies.


13 June 2026 in Buildings
Verified
Journal Article
Open access
PDF file
Christina BetzoldChristina Betzold
Christina Betzold
SHSebastian Hummel
Sebastian Hummel
ADArno Dentel
Arno Dentel
This paper presents a comprehensive evaluation of control strategies for a highly energy-efficient plus-energy terraced housing complex equipped with photovoltaic generation, modulating ground-source heat pumps, electrical and thermal energy storage systems, and activation of building thermal mass. The study combines long-term monitoring data, annual simulations, and hardware-in-the-loop (HiL) experiments to assess modulating heat-controlled operation (HC), PV-controlled (PVC), and predictive control strategies, including simple predictive control (SPC) and model predictive control (MPC). The simulation results show that the baseline HC operation already achieves a high load cover factor (LCF), defined as the fraction of total electrical demand covered by local PV generation (direct use + battery discharge) of 65.6% and a seasonal performance factor (SPF) of the central heat pumps of 5.8. PVC increases LCF (71.0%) by shifting heat pump operation toward PV-rich periods but leads to elevated storage temperatures up to 5 K and a reduced SPF of 4.8. MPC further enhances LCF by 4–7 percentage points in simulated and HiL environments. However, its real-world performance is strongly influenced by forecast quality and the limited controllability of the heat pump system. In addition, building thermal mass activation is investigated as a complementary flexibility option. Simulation and monitoring results demonstrate that moderate room temperature set-point (2 K) increases during PV availability significantly improve LCF from 20% to 55% while maintaining thermal comfort. Overall, the findings indicate that in highly efficient plus-energy buildings, robust rule-based strategies combined with thermal mass activation can achieve a large share of the attainable benefits, while the added complexity of MPC must be carefully weighed against practical limitations.