Vasiliki Keramari

Dr. Vasiliki Keramari


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
VKVasiliki Keramari
Vasiliki Keramari
Stella GirousiStella Girousi
Stella Girousi
This review examines the emerging role of manganese-based nanoparticles (Mn-NPs) in detecting heavy metal pollutants in environmental matrices. Heavy metals such as cadmium, lead, zinc, and copper pose serious environmental and health concerns due to their tendency to persist in ecosystems and accumulate in living organisms. As a result, there is a growing need for reliable methods to detect and remove these pollutants. Manganese nanoparticles offer unique advantages that scientists could consider as replacing other metal nanoparticles, which may be more expensive or more toxic. The physicochemical properties of Mn-NPs—including their multiple oxidation states, magnetic susceptibility, catalytic capabilities, and semiconductor conductivity—enable the development of multi-modal sensing platforms with exceptional sensitivity and selectivity. While Mn-NPs exhibit inherently low electrical conductivity, strategies such as transition metal doping and the formation of composites with conductive materials have successfully addressed this limitation. Compared to noble metal nanoparticles (Au, Ag, Pd) and other base metal nanoparticles (Bi, Fe3O4), Mn-NPs demonstrate competitive performance without the drawbacks of high cost, complex synthesis, poor distribution control, or significant aggregation. Preliminary studies retrieved from the Scopus database highlight promising applications of manganese-based nanomaterials in electrochemical sensing of heavy metals, with recent developments showing detection limits in the sub-ppb range. Future research directions should focus on addressing challenges related to scalability, cost-effectiveness, and integration with existing water treatment infrastructure to accelerate the transition from laboratory findings to practical environmental applications.

18 June 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
VKVasiliki Keramari
Vasiliki Keramari
SPSotiria G. Papadimou
Sotiria G. Papadimou
Evangelia E. GoliaEvangelia E. Golia
Evangelia E. Golia
Stella GirousiStella Girousi
Stella Girousi
Heavy metals constitute pollutants that are particularly common in air, water, and soil. They are present in both urban and rural environments, on land, and in marine ecosystems, where they cause serious environmental problems since they do not degrade easily, remain almost unchanged for long periods, and bioaccumulate. The detection and especially the quantification of metals require a systematic process. Regular monitoring is necessary because of seasonal variations in metal levels. Consequently, there is a significant need for rapid and low-cost metal determination methods. In this study, we compare and analytically validate absorption spectrometry with a sensitive voltammetric method, which uses a bismuth film-plated electrode surface and applies stripping voltammetry. Atomic absorption spectroscopy (AAS) represents a well-established analytical technique, while the applicability of anodic stripping voltammetry (ASV) in complicated sample matrices such as soil samples is currently unknown. This sample-handling challenge is investigated in the present study. The results show that the AAS and ASV methods were satisfactorily correlated and showed that the metal concentration in soils was lower than the limit values but with an increasing trend. Therefore, continuous monitoring of metal levels in the urban complex of a city is necessary and a matter of great importance. The limits of detection of cadmium (Cd) were lower when using the stripping voltammetry (SWASV) graphite furnace technique compared with those obtained with AAS when using the graphite furnace. However, when using flame atomic absorption spectroscopy (flame-AAS), the measurements tended to overestimate the concentration of Cd compared with the values found using SWASV. This highlights the differences in sensitivity and accuracy between these analytical methods for detecting Cd. The SWASV method has the advantage of being cheaper and faster, enabling the simultaneous determination of heavy elements across the range of concentrations that these elements can occur in Mediterranean soils. Additionally, a dsDNA biosensor is suggested for the discrimination of Cu(I) along with Cu(II) based on the oxidation peak of guanine, and adenine residues can be applied in the redox speciation analysis of copper in soil, which represents an issue of great importance.

5 March 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
Stella GirousiStella Girousi
Stella Girousi
VKVasiliki Keramari
Vasiliki Keramari
IPIoanna Paraschi
Ioanna Paraschi
SKSophia Karastogianni
Sophia Karastogianni
Evangelia E. GoliaEvangelia E. Golia
Evangelia E. Golia
A simple and easily applicable analytical method for the simultaneous determination of Cd2+, Pb2+, Zn2+, Cu2+, and Cl− by applying a modified carbon paste electrode with saffron-conjugated silver nanoparticles (AgNPs@Sa) is being presented. The modified CPE was then used for the simultaneous determination of Cd2+, Pb2+, Zn2+, and Cu2+ as well as chloride ions in soil and plants. The comparative analysis demonstrated a significant enhancement in the applicability of the modified electrode through the incorporation of silver nanoparticles (AgNPs) at the carbon paste electrode (CPE) surface, leading to the development of a poly-Sa-CPE. This newly proposed method offers notably superior qualitative performance compared to other metal nanoparticle-based modifications reported in the literature. The accordingly modified electrode was successfully applied in the development of a chloride ion. A novel sensor is being proposed that makes possible the determination of heavy metals and chlorides in the same solution, in soil and plant samples. The enhanced sensitivity and selectivity of the poly-Sa-CPE system highlights its potential as a more effective alternative for heavy metal and chloride analysis, further demonstrating its advantages in electrochemical applications. The LODs of Cd2+, Pb2+, Zn2+, Cu2+, and Cl− for their simultaneous determination are 0.38 μg·L−1, 0.44 μg·L−1, 0.72 μg·L−1, 0.42 μg·L−1, and 0.11 μg·L−1, respectively, with comparably high relative standard deviations of about 8.1%, 9.4%, 8.3%, 7.6%, and 7.9%, respectively.

28 February 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
VKVasiliki Keramari
Vasiliki Keramari
Catherine Dendrinou-SamaraCatherine Dendrinou-Samara
Catherine Dendrinou-Samara
ZKZoi Kourpouanidou
Zoi Kourpouanidou
LPLambrini Papadopoulou
Lambrini Papadopoulou
Aristidis AnthemidisAristidis Anthemidis
Aristidis Anthemidis
Stella GirousiStella Girousi
Stella Girousi
In this work, a novel nanostructured Mn3O4-based electrochemical sensor was developed for the determination of heavy metals in aqueous media. The Mn3O4 nanostructure was solvothermally synthesized in the sole presence of propylene glycol (PG). Under the specific synthetic conditions, PG provided surface coating and stabilization by decomposition products and/or residual PG molecules that have been adsorbed on Mn3O4 NPs surfaces, creating a thin organic layer. This imparts a negative surface charge (zeta potential), enhancing colloidal stability in dispersions and electrochemical performance. The physicochemical properties of the resulting NPs were characterized via X-ray diffraction (XRD), Fourier transform infrared (FT-IR), Thermogravimetric Analysis (TGA), and Dynamic light scattering (DLS) and ζ-potential measurements, as well as SEM imaging of the modified electrode surface, confirming its successful formation and favorable structural properties. The LODs of Cd2+, Pb2+, Zn2+, and Cu2+ for their simultaneous determination are 2.9 μg·L−1, 5.2 μg·L−1, 7.1 μg·L−1, and 2.5 μg·L−1, respectively, with relative standard deviations of about 5.24%, 4.43%, 7.74%, and 4.53%, respectively. As a result of this study, a simple, sensitive, and reproducible electrochemical sensor based on a carbon paste electrode (CPE) modified with novel synthesized manganese nanoparticles and employing voltammetric techniques was applied in water and wastewater.

22 July 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
VKVasiliki Keramari
Vasiliki Keramari
Stella GirousiStella Girousi
Stella Girousi
This review examines the emerging role of manganese-based nanoparticles (Mn-NPs) in detecting heavy metal pollutants in environmental matrices. Heavy metals such as cadmium, lead, zinc, and copper pose serious environmental and health concerns due to their tendency to persist in ecosystems and accumulate in living organisms. As a result, there is a growing need for reliable methods to detect and remove these pollutants. Manganese nanoparticles offer unique advantages that scientists could consider replacing other metal nanoparticles, which may be more expensive or more toxic. The physicochemical properties of Mn-NPs—including their multiple oxidation states, magnetic susceptibility, catalytic capabilities, and semiconductor conductivity—enable the development of multi-modal sensing platforms with exceptional sensitivity and selectivity. While Mn-NPs exhibit inherently low electrical conductivity, strategies such as transition metal doping and the formation of composites with conductive materials have successfully addressed this limitation. Compared to noble metal nanoparticles (Au, Ag, Pd) and other base metal nanoparticles (Bi, Fe₃O₄), Mn-NPs demonstrate competitive performance without the drawbacks of high cost, complex synthesis, poor distribution control, or significant aggregation. Preliminary studies retrieved from the Scopus database highlight promising applications of manganese-based nanomaterials in electrochemical sensing of heavy metals, with recent developments showing detection limits in the sub-ppb range. Future research directions should focus on addressing challenges related to scalability, cost-effectiveness, and integration with existing water treatment infrastructure to accelerate the transition from laboratory findings to practical environmental applications.

13 January 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Stella GirousiStella Girousi
Stella Girousi
VKVasiliki Keramari
Vasiliki Keramari
IPIoanna Paraschi
Ioanna Paraschi
SKSophia Karastogianni
Sophia Karastogianni
Evangelia E. GoliaEvangelia E. Golia
Evangelia E. Golia
A simple and easily applicable analytical method for the simultaneous determination of Cd2+, Pb2+, Zn2+, Cu2+, and Cl- applying a modified with saffron-conjugated silver nanoparticles (AgNPs@Sa) is being presented. The modified CPE was then used for the simultaneous determination of Cd2+, Pb2+, Zn2+, and Cu2+ as well as chloride ions in soil and plants. The comparative analysis demonstrated a significant enhancement in the applicability of the modified electrode through the incorporation of silver nanoparticles (AgNPs) at the carbon paste electrode (CPE) surface, leading to the development of a poly-Sa-CPE. This newly proposed method offers notably superior qualitative performance compared to other metal nanoparticle-based modifications reported in the literature. The accordingly modified electrode was successfully applied in the development of a chloride ion. A novel sensor, is being proposed, that makes possible the determination of heavy metals and chorides in the same solution, in soil and plant samples. The enhanced sensitivity and selectivity of the poly-Sa-CPE system highlights its potential as a more effective alternative for heavy metal and chloride analysis, further demonstrating its advantages in electrochemical applications.