This paper investigates the use of an Electronic Power Transformer (EPT) incorporated with an energy storage system to smooth the wind power fluctuations and enhance the low voltage ride-through (LVRT) capability of directly driven wind turbines with permanent magnet synchronous generators (D-PMSGs). The decoupled control schemes of the system, including the grid side converter control scheme, generator side converter control scheme and the control scheme of the energy storage system, are presented in detail. Under normal operating conditions, the energy storage system absorbs the high frequency component of the D-PMSG output power to smooth the wind power fluctuations. Under grid fault conditions, the energy storage system absorbs the redundant power, which could not be transferred to the grid by the EPT, to help the D-PMSG to ride through low voltage conditions. This coordinated control strategy is validated by simulation studies using MATLAB/Simulink. With the proposed control strategy, the output wind power quality is improved and the D-PMSG can ride through severe grid fault conditions.
To enhance the operational efficiency of energy storage converters in grid-connected systems with high renewable penetration, this study systematically investigates key technologies of active neutral-point clamped (ANPC) topology under “electrical–thermal–mechanical” multi-physical field coupling. The study reviews recent progress in structural design, modulation strategies, and fault-tolerant control, highlighting their impact on efficiency, reliability, and power density. At the structural stage, a hybrid SiC/IGBT device configuration combined with a three-dimensional stacked bus reduces conduction loss and achieves parasitic inductance. In the modulation stage, improved finite-set model predictive control and adaptive space vector modulation shorten computation time to 20 µs and keep total harmonic distortion (THD) within 2.8%. System-level evaluations demonstrate that a 250 kW ANPC converter attains a peak efficiency of 99.1%, a power density of 4.5 kW/kg, and a mean time between failure exceeding 150,000 h. These findings reveal a clear transition from single-objective performance improvement toward integrated multi-physics co-design. By unifying advanced modulation, intelligent fault-tolerant control, and multi-field coupling optimization, ANPC-based converters advance converters to a new stage of higher efficiency, reliability, and stability. The results provide essential technical support for next-generation power conversion systems in renewable-rich grids.