Ji-Jon Sit

Dr. Ji-Jon Sit

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2005 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RSR. Sarpeshkar
R. Sarpeshkar
CSC. Salthouse
C. Salthouse
JSJi-Jon Sit
Ji-Jon Sit
MBM.W. Baker
M.W. Baker
SZS.M. Zhak
S.M. Zhak
SBS. Balster
S. Balster
We report a programmable analog bionic ear (cochlear implant) processor in a 1.5-/spl mu/m BiCMOS technology with a power consumption of 211 /spl mu/W and 77-dB dynamic range of operation. The 9.58 mm/spl times/9.23 mm processor chip runs on a 2.8 V supply and has a power consumption that is lower than state-of-the-art analog-to-digital (A/D)-then-DSP designs by a factor of 25. It is suitable for use in fully implanted cochlear-implant systems of the future which require decades of operation on a 100-mAh rechargeable battery with a finite number of charge-discharge cycles. It may also be used as an ultra-low-power spectrum-analysis front end in portable speech-recognition systems. The power consumption of the processor includes the 100 /spl mu/W power consumption of a JFET-buffered electret microphone and an associated on-chip microphone front end. An automatic gain control circuit compresses the 77-dB input dynamic range into a narrower internal dynamic range (IDR) of 57 dB at which each of the 16 spectral channels of the processor operate. The output bits of the processor are scanned and reported off chip in a format suitable for continuous-interleaved-sampling stimulation of electrodes. Power-supply-immune biasing circuits ensure robust operation of the processor in the high-RF-noise environment typical of cochlear implant systems.

1 September 2007 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
JSJi-Jon Sit
Ji-Jon Sit
RSRahul Sarpeshkar
Rahul Sarpeshkar
Large dc blocking capacitors are a bottleneck in reducing the size and cost of neural implants. We describe an electrode-stimulator chip that removes the need for large dc blocking capacitors in neural implants by achieving precise charge-balanced stimulation with <6 nA of dc error. For cochlear implant patients, this is well below the industry's safety limit of 25 nA. Charge balance is achieved by dynamic current balancing to reduce the mismatch between the positive and negative phases of current to 0.4%, followed by a shorting phase of at least 1 ms between current pulses to further reduce the charge error. On +6 and -9 V rails in a 0.7-mum AMI high voltage process, the power consumption of a single channel of this chip is 47 muW when biasing power is shared by 16 channels.

19 December 2006 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JSJi-Jon Sit
Ji-Jon Sit
ASAndrea M. Simonson
Andrea M. Simonson
AOAndrew J. Oxenham
Andrew J. Oxenham
MFMichael A. Faltys
Michael A. Faltys
RSRahul Sarpeshkar
Rahul Sarpeshkar
Cochlear implants currently fail to convey phase information, which is important for perceiving music, tonal languages, and for hearing in noisy environments. We propose a bio-inspired asynchronous interleaved sampling (AIS) algorithm that encodes both envelope and phase information, in a manner that may be suitable for delivery to cochlear implant users. Like standard continuous interleaved sampling (CIS) strategies, AIS naturally meets the interleaved-firing requirement, which is to stimulate only one electrode at a time, minimizing electrode interactions. The majority of interspike intervals are distributed over 1-4 ms, thus staying within the absolute refractory limit of neurons, and form a more natural, pseudostochastic pattern of firing due to complex channel interactions. Stronger channels are selected to fire more often but the strategy ensures that weaker channels are selected to fire in proportion to their signal strength as well. The resulting stimulation rates are considerably lower than those of most modern implants, saving power yet delivering higher potential performance. Correlations with original sounds were found to be significantly higher in AIS reconstructions than in signal reconstructions using only envelope information. Two perceptual tests on normal-hearing listeners verified that the reconstructed signals enabled better melody and speech recognition in noise than those processed using tone-excited envelope-vocoder simulations of cochlear implant processing. Thus, our strategy could potentially save power and improve hearing performance in cochlear implant users

30 August 2005
Verified
Conference Paper
Closed access
RSR. Sarpeshkar
R. Sarpeshkar
MBM.W. Baker
M.W. Baker
CSC.D. Salthouse
C.D. Salthouse
JSJi-Jon Sit
Ji-Jon Sit
LTL. Turicchia
L. Turicchia
SZS.M. Zhak
S.M. Zhak

10 June 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
GFGuangyin Feng
Guangyin Feng
JSJi-Jon Sit
Ji-Jon Sit
This paper presents a closed-loop transmitter for wireless power transfer with automatic resonance frequency tracking to maintain high power transfer efficiency in the over-coupled region. The transmitter consists of a source oscillator, power amplifier (PA), PA driver, matching network, and feedback circuitry. By injecting the resonant output of coupled antenna coils into a source oscillator to form a positive feedback loop, the source oscillator is injection-locked and the closed-loop transmitter functions as a power oscillator with the oscillation frequency determined by the resonance of the coupled coils. The proposed resonant frequency tracking minimizes the change in the input impedance presented to the PA, and hence mitigates mismatch that causes a sharp drop in the PA efficiency of conventional transmitters. Implemented in 0.13μm BCD (Bipolar-CMOS-DMOS) technology, the prototype maintains PA efficiency above 60% even at highly over-coupled spacings (10mm), which is significantly below the critical coupling spacing (40mm). Compared to a transmitter without feedback (i.e. running in open loop), the transfer efficiency at a charging distance of 10mm is improved by 6.6 times and the charging range with power transfer efficiency over 50% is also doubled.

16 January 2008 in IEEE Pervasive Computing
Verified
Journal Article
Closed access
JSJi-Jon Sit
Ji-Jon Sit
RSRahul Sarpeshkar
Rahul Sarpeshkar
Cochlear implants (CIs), or bionic ears, restore hearing in profoundly deaf (greater than -90 dB hearing loss) patients. They function by transforming frequency patterns in sound into corresponding spatial electrode-stimulation patterns for the auditory nerve. Over the past 20 years, improvements in sound-processing strategies, in the number of electrodes and channels, and in the rate of stimulation have yielded improved sentence and word recognition scores in patients. Next- generation implants will be fully implanted inside the patient's body. Consequently, power consumption requirements for signal processing will be very stringent.