Li JingBo

Dr. Li JingBo

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2020 in Dalton Transactions
Verified
Journal Article
Closed access
PDF file
LJLi JingBo
Li JingBo
YLYu Liu
Yu Liu
WCWei Cao
Wei Cao
NCNan Chen
Nan Chen
A rapid in situ method was employed to synthesize the β-Ni(OH) 2 @NF integrated electrode for a high performance ASC device.

28 February 2020 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
PDF file
LJLi JingBo
Li JingBo
YLYu Liu
Yu Liu
FXFang Xu
Fang Xu
JHJunping Hu
Junping Hu
NCNan Chen
Nan Chen
CJChangshuang Jiang
Changshuang Jiang

5 September 2025 in Materials
Verified
Journal Article
Open access
PDF file
XMXudong Mao
Xudong Mao
BZBaoqing Zhou
Baoqing Zhou
HDHui Deng
Hui Deng
QZQiong Zeng
Qiong Zeng
LJLi JingBo
Li JingBo
KCKuo-chih Chou
Kuo-chih Chou
The adsorption of gas reactant molecules (H2, CO, etc.) to the surface of hematite is the premise of chemical reaction. In order to further promote the basic research on the reaction mechanism of hematite reduction by a H2-CO gas mixture, the adsorption behavior of H2 (or CO) under the conditions of pre-adsorbed H2O (or CO2) was systematically studied by the density functional theory (DFT) combined with reduction experiments. The results indicate that the gas molecules (H2, CO, H2O and CO2) adsorbed on the Fe atom of the Fe2O3 (001) surface rather than the O atom, and the adsorption energy of the Fe2O3-CO adsorption system was relatively minimum (−1.317 eV), indicating that the Fe2O3-CO adsorption system was more stable. In addition, the adsorption energy of the H2 molecule adsorbed to the Fe2O3-H2O adsorption system was −0.132 eV, which was smaller than that of the H2 molecule directly adsorbed to Fe2O3 (−0.013 eV), indicating that the H2O molecule pre-adsorption was beneficial to the H2 molecule adsorption. Compared with the H2O molecule, the CO2 molecule had relatively less influence on the adsorption and subsequent behavior of CO with Fe2O3. From the experiment analysis results, on the whole, CO2 had a greater impact on the gas diffusion, while H2O had a greater impact on the interfacial chemical reaction (gas adsorption), which was consistent with the DFT calculation results.

31 August 2026 in Materials
Verified
Journal Article
Open access
PDF file
LJLi JingBo
Li JingBo
GLGuopeng Li
Guopeng Li
JWJiawei Wei
Jiawei Wei
ZGZhenxiang Gao
Zhenxiang Gao
PXPengfei Xiang
Pengfei Xiang
YXYong Xia
Yong Xia
Shortwave infrared (SWIR) imaging technology, with its excellent penetration and anti-interference capabilities, is widely applied in military, medical, and industrial fields. However, traditional detectors (e.g., InGaAs) are expensive, have complex readout circuits, and exhibit insufficient low-light performance, limiting their large-scale promotion. This paper proposes and implements a single-pixel SWIR imaging system based on PbS quantum dot (QD) detectors. A single-pixel imaging system is constructed using PbS QD detectors with a formal device structure (ITO/ZnO/PbS/PbS-EDT/Au); through simulation studies, the effect of the PbS absorption layer thickness on device performance is investigated, and it is determined that a thickness of 450 nm yields optimal device performance. Based on the simulation results, a P-I-N structure PbS photovoltaic-type detector with high external quantum efficiency (EQE) and low dark current is fabricated, achieving a EQE of 62% at the 1300 nm wavelength, a dark current density of 8.54 × 10−4 mA·cm−2 at −0.1 V bias voltage, and a −3 dB bandwidth of 324 kHz; a low-noise signal conditioning circuit is designed to optimize the −3 dB bandwidth to 337 kHz while maintaining low noise density, enabling the linear conversion of nA~μA level weak photocurrent from the detector to 0~3 V standardized voltage signals, meeting the requirements of single-pixel imaging (SPI) systems. Hadamard orthogonal encoding technology is employed to achieve spatial light modulation and signal encoding; after the PbS QD detector collects and integrates the projection signal, the image with 128 × 128 resolution is reconstructed through the inverse Hadamard orthogonal decoding algorithm. This work provides a novel solution for QD-based SWIR imaging, overcoming the cost and manufacturing limitations of traditional array systems and laying the foundation for the spectral expansion and practical application of SPI technology. Quantitative imaging characterization and low-light imaging tests are supplemented to verify the comprehensive performance of the system.