The adsorption of gas reactant molecules (H2, CO, etc.) to the surface of hematite is the premise of chemical reaction. In order to further promote the basic research on the reaction mechanism of hematite reduction by a H2-CO gas mixture, the adsorption behavior of H2 (or CO) under the conditions of pre-adsorbed H2O (or CO2) was systematically studied by the density functional theory (DFT) combined with reduction experiments. The results indicate that the gas molecules (H2, CO, H2O and CO2) adsorbed on the Fe atom of the Fe2O3 (001) surface rather than the O atom, and the adsorption energy of the Fe2O3-CO adsorption system was relatively minimum (−1.317 eV), indicating that the Fe2O3-CO adsorption system was more stable. In addition, the adsorption energy of the H2 molecule adsorbed to the Fe2O3-H2O adsorption system was −0.132 eV, which was smaller than that of the H2 molecule directly adsorbed to Fe2O3 (−0.013 eV), indicating that the H2O molecule pre-adsorption was beneficial to the H2 molecule adsorption. Compared with the H2O molecule, the CO2 molecule had relatively less influence on the adsorption and subsequent behavior of CO with Fe2O3. From the experiment analysis results, on the whole, CO2 had a greater impact on the gas diffusion, while H2O had a greater impact on the interfacial chemical reaction (gas adsorption), which was consistent with the DFT calculation results.
Shortwave infrared (SWIR) imaging technology, with its excellent penetration and anti-interference capabilities, is widely applied in military, medical, and industrial fields. However, traditional detectors (e.g., InGaAs) are expensive, have complex readout circuits, and exhibit insufficient low-light performance, limiting their large-scale promotion. This paper proposes and implements a single-pixel SWIR imaging system based on PbS quantum dot (QD) detectors. A single-pixel imaging system is constructed using PbS QD detectors with a formal device structure (ITO/ZnO/PbS/PbS-EDT/Au); through simulation studies, the effect of the PbS absorption layer thickness on device performance is investigated, and it is determined that a thickness of 450 nm yields optimal device performance. Based on the simulation results, a P-I-N structure PbS photovoltaic-type detector with high external quantum efficiency (EQE) and low dark current is fabricated, achieving a EQE of 62% at the 1300 nm wavelength, a dark current density of 8.54 × 10−4 mA·cm−2 at −0.1 V bias voltage, and a −3 dB bandwidth of 324 kHz; a low-noise signal conditioning circuit is designed to optimize the −3 dB bandwidth to 337 kHz while maintaining low noise density, enabling the linear conversion of nA~μA level weak photocurrent from the detector to 0~3 V standardized voltage signals, meeting the requirements of single-pixel imaging (SPI) systems. Hadamard orthogonal encoding technology is employed to achieve spatial light modulation and signal encoding; after the PbS QD detector collects and integrates the projection signal, the image with 128 × 128 resolution is reconstructed through the inverse Hadamard orthogonal decoding algorithm. This work provides a novel solution for QD-based SWIR imaging, overcoming the cost and manufacturing limitations of traditional array systems and laying the foundation for the spectral expansion and practical application of SPI technology. Quantitative imaging characterization and low-light imaging tests are supplemented to verify the comprehensive performance of the system.