Giorgio Biagetti

Dr. Giorgio Biagetti

DII—Dipartimento di Ingegneria dell’Informazione, Università Politecnica delle Marche, Via Brecce Bianche 12, I-60131 Ancona, Italy
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MAMichele Alessandrini
Michele Alessandrini
GBGiorgio Biagetti
Giorgio Biagetti
Paolo CrippaPaolo Crippa
Paolo Crippa
Laura FalaschettiLaura Falaschetti
Laura Falaschetti
Simona LuzziSimona Luzzi
Simona Luzzi
Claudio TurchettiClaudio Turchetti
Claudio Turchetti
The use of electroencephalography (EEG) has recently grown as a means to diagnose neurodegenerative pathologies such as Alzheimer’s disease (AD). AD recognition can benefit from machine learning methods that, compared with traditional manual diagnosis methods, have higher reliability and improved recognition accuracy, being able to manage large amounts of data. Nevertheless, machine learning methods may exhibit lower accuracies when faced with incomplete, corrupted, or otherwise missing data, so it is important do develop robust pre-processing techniques do deal with incomplete data. The aim of this paper is to develop an automatic classification method that can still work well with EEG data affected by artifacts, as can arise during the collection with, e.g., a wireless system that can lose packets. We show that a recurrent neural network (RNN) can operate successfully even in the case of significantly corrupted data, when it is pre-filtered by the robust principal component analysis (RPCA) algorithm. RPCA was selected because of its stated ability to remove outliers from the signal. To demonstrate this idea, we first develop an RNN which operates on EEG data, properly processed through traditional PCA; then, we use corrupted data as input and process them with RPCA to filter outlier components, showing that even with data corruption causing up to 20% erasures, the RPCA was able to increase the detection accuracy by about 5% with respect to the baseline PCA.

20 November 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
GBGiorgio Biagetti
Giorgio Biagetti
Paolo CrippaPaolo Crippa
Paolo Crippa
Laura FalaschettiLaura Falaschetti
Laura Falaschetti
Simone OrcioniSimone Orcioni
Simone Orcioni
Claudio TurchettiClaudio Turchetti
Claudio Turchetti
The human activity monitoring technology is one of the most important technologies for ambient assisted living, surveillance-based security, sport and fitness activities, healthcare of elderly people. The activity monitoring is performed in two steps: the acquisition of body signals and the classification of activities being performed. This paper presents a low-cost wearable wireless system specifically designed to acquire surface electromyography (sEMG) and accelerometer signals for monitoring the human activity when performing sport and fitness activities, as well as in healthcare applications. The proposed system consists of several ultralight wireless sensing nodes that are able to acquire, process and efficiently transmit the motion-related (biological and accelerometer) body signals to one or more base stations through a 2.4 GHz radio link using an ad-hoc communication protocol designed on top of the IEEE 802.15.4 physical layer. A user interface software for viewing, recording, and analysing the data was implemented on a control personal computer that is connected through a USB link to the base stations. To demonstrate the capability of the system of detecting the user’s activity, data recorded from a few subjects were used to train and test an automatic classifier for recognizing the type of exercise being performed. The system was tested on four different exercises performed by three people, the automatic classifier achieved an overall accuracy of 85.7% combining the features extracted from acceleration and sEMG signals. A low cost wireless system for the acquisition of sEMG and accelerometer signals has been presented for healthcare and fitness applications. The system consists of wearable sensing nodes that wirelessly transmit the biological and accelerometer signals to one or more base stations. The signals so acquired will be combined and processed in order to detect, monitor and recognize human activities.

17 July 2021 in Electronics
Verified
Journal Article
Open access
PDF file
MAMichele Alessandrini
Michele Alessandrini
GBGiorgio Biagetti
Giorgio Biagetti
Paolo CrippaPaolo Crippa
Paolo Crippa
Laura FalaschettiLaura Falaschetti
Laura Falaschetti
Claudio TurchettiClaudio Turchetti
Claudio Turchetti
Photoplethysmography (PPG) is a common and practical technique to detect human activity and other physiological parameters and is commonly implemented in wearable devices. However, the PPG signal is often severely corrupted by motion artifacts. The aim of this paper is to address the human activity recognition (HAR) task directly on the device, implementing a recurrent neural network (RNN) in a low cost, low power microcontroller, ensuring the required performance in terms of accuracy and low complexity. To reach this goal, (i) we first develop an RNN, which integrates PPG and tri-axial accelerometer data, where these data can be used to compensate motion artifacts in PPG in order to accurately detect human activity; (ii) then, we port the RNN to an embedded device, Cloud-JAM L4, based on an STM32 microcontroller, optimizing it to maintain an accuracy of over 95% while requiring modest computational power and memory resources. The experimental results show that such a system can be effectively implemented on a constrained-resource system, allowing the design of a fully autonomous wearable embedded system for human activity recognition and logging.

1 April 2020 in Data in Brief
Verified
Journal Article
Open access
GBGiorgio Biagetti
Giorgio Biagetti
Paolo CrippaPaolo Crippa
Paolo Crippa
Laura FalaschettiLaura Falaschetti
Laura Falaschetti
LSLeonardo Saraceni
Leonardo Saraceni
ATAndrea Tiranti
Andrea Tiranti
Claudio TurchettiClaudio Turchetti
Claudio Turchetti
We introduce a dataset to provide insights about the photoplethysmography (PPG) signal captured from the wrist in presence of motion artifacts and the accelerometer signal, simultaneously acquired from the same wrist. The data presented were collected by the electronics research team of the Department of Information Engineering, Polytechnic University of Marche, Ancona, Italy. This article describes data recorded from 7 subjects and includes 105 PPG signals (15 for each subject) and the corresponding 105 tri-axial accelerometer signals measured with a sampling frequency of 400 Hz. These data can be reused for testing machine learning algorithms for human activity recognition.

4 June 2020 in Electronics
Verified
Journal Article
Open access
PDF file
GBGiorgio Biagetti
Giorgio Biagetti
Paolo CrippaPaolo Crippa
Paolo Crippa
Laura FalaschettiLaura Falaschetti
Laura Falaschetti
Claudio TurchettiClaudio Turchetti
Claudio Turchetti
This paper proposes a wireless sensor device for the real-time acquisition of bioelectrical signals such as electromyography (EMG) and electrocardiography (ECG), coupled with an inertial sensor, to provide a comprehensive stream of data suitable for human activity detection, motion analysis, and technology-assisted nursing of persons with physical or cognitive impairments. The sensor is able to acquire up to three independent bioelectrical channels (six electrodes), each with 24 bits of resolution and a sampling rate up to 3.2 kHz, and has a 6-DoF inertial platform measuring linear acceleration and angular velocity. The bluetooth low-energy wireless link was chosen because it allows easy interfacing with many consumer electronics devices, such as smartphones or tablets, that can work as data aggregators, but also imposes data rate restrictions. These restrictions are investigated in this paper as well, together with the strategy we adopted to maximize the available bandwidth and reliability of the transmission within the limits imposed by the protocol.

19 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Laura FalaschettiLaura Falaschetti
Laura Falaschetti
GBGiorgio Biagetti
Giorgio Biagetti
MAMichele Alessandrini
Michele Alessandrini
Claudio TurchettiClaudio Turchetti
Claudio Turchetti
Simona LuzziSimona Luzzi
Simona Luzzi
Paolo CrippaPaolo Crippa
Paolo Crippa
Neurodegenerative diseases severely impact the life of millions of patients worldwide, and their occurrence is more and more increasing proportionally to longer life expectancy. Electroencephalography has become an important diagnostic tool for these diseases, due to its relatively simple procedure, but it requires analyzing a large number of data, often carrying a small fraction of informative content. For this reason, machine learning tools have gained a considerable relevance as an aid to classify potential signs of a specific disease, especially in its early stages, when treatments can be more effective. In this work, long short-term memory-based neural networks with different numbers of units were properly designed and trained after accurate data pre-processing, in order to perform a multi-class detection. To this end, a custom dataset of EEG recordings from subjects affected by five neurodegenerative diseases (Alzheimer’s disease, frontotemporal dementia, dementia with Lewy bodies, progressive supranuclear palsy, and vascular dementia) was acquired. Experimental results show that an accuracy up to 98% was achieved with data belonging to different classes of disease, up to six including the control group, while not requiring particularly heavy computational resources.