Background: The use of postoperative MRI to assess the healing status of repaired menisci is a long-standing issue. This study evaluates and compares functional and MRI outcomes following an arthroscopic meniscus repair procedure with the aim of postoperative MRI diagnostic accuracy clarification in young patients. Methods: A total of 35 patients under 18 years old who underwent isolated meniscus repair were included. The Pedi-IKDC score, Lysholm score, and Tegner activity index (TAS) were compared between the groups formed according to the Stroller and Crues three-grade classification of postoperative MRI-based evaluations. Grade 3 MRI views were classified as unhealed, grade 2 as partially healed, and grade 1 as fully healed within the repaired meniscus, whereas grade 3 cases were considered unsuccessful due to MRI evaluation. Results: MRI assessment revealed 4 cases of grade 1 (11.4%), 14 cases of grade 2 (40.8%), and 17 cases of grade 3 (48.0%) lesions. Pedi-IKDC and TAS scores were significantly higher among MRI grade 2 patients than among MRI grade 3 patients (p < 0.05). Weak negative correlations between MRI grades and all functional scales were found (p < 0.05). ROC analysis showed that Pedi-IKDC and TAS scores could correctly classify 77% and 71% of MRI grade 3 patients, respectively. The optimal cut-off values to detect grade 3 patients were 88.74 for the Pedi-IKDC score and 4.5 for the TAS score. Conclusions: To conclude, established functional score cut-off values may help identify unhealed meniscus repair patients.
Background and Objectives: The menisci are crucial fibrocartilaginous structures of the knee joint and have to be repaired in case of a tear. However, not all meniscal tears heal, even in young patients. Fibrin clot (FC) started to be used to reduce the failure rates following meniscus repair. The purpose of this study is to evaluate and compare outcomes after isolated arthroscopic meniscal repair augmented with FC versus without FC. Materials and Methods: Fifty-nine patients aged under 19 with isolated meniscal tears were randomized into two groups: one group underwent the meniscal repair with FC (FC-augmented), and the other group did not receive FC (control). The evaluation and comparison between the groups based on FC augmentation included secondary arthroscopy rates, patient-reported outcome measures (Pedi-IKDC, Lysholm, and Tegner), and clinical and radiological (MRI) assessments at a median follow-up of 12 months. Results: No statistically significant difference was observed between FC-augmented and control groups in Pedi-IKDC, Lysholm, and TAG scores, or following clinical and radiological (MRI) evaluation. Patients in the FC-augmented group reported fewer clinical symptoms at the final follow-up across unstable and demanding (bucket-handle and complex) tear type subgroups (p = 0.012 and 0.041, respectively). Overall, nine revision arthroscopies occurred in both groups (2 and 7, respectively), all across bucket-handle and complex tears with no significant difference between the FC-augmented and control groups (p = 0.072). Conclusions: This pilot study found that FC usage during meniscal repair reduces clinical symptoms for patients with unstable, bucket-handle, or complex meniscal tears at the final follow-up of 12 months postoperatively. Nonetheless, no statistically significant differences were observed within the other outcome measures between the FC-augmented and control groups and subgroups based on meniscal tear types. Level of evidence: Level II.
1 January 2023 in Acta Orthopaedica et Traumatologica Turcica
Objective: This study aimed to compare inter- and intra-observer agreement between radiographs with 2-dimensional and 3-dimensional computed tomography scans with and without 3-dimensional printed models in the evaluation of the distal radius fracture of Association for Osteo synth esis/ Ortho paedi c Trauma Association type C classification. Methods: Fifteen consecutive cases with X-Rays, 2-dimensional and 3-dimensional computed tomography reconstructions views, and 3-dimensional printed models were selected. Three-dimensional printed models of the distal radius fractures were created using 2-dimensional computed tomography scan files in Digital Imaging and Communication in Medicine format, processed with the 3-dimensional Slicer software, and segmented, creating a 3-dimensional printed model in Standard Triangle Language format. Threedimensional models were printed using fused deposition modeling (FDM) type 3D printer Zortrax M200Plus using polylactic acid material on a scale of 1 : 1. Twenty observers were invited into the study. Results: Intra- and inter-observer reliability was analyzed using Fleiss’ kappa statistics. Overall kappa values for both groups in interobserver agreement range from 0.113 to 0.283 and in intra-observer agreement from 0.25 to 0.545. Generally, inter-observer agreement increased with additional 3-dimensional printed models from slight to fair, and intra-observer agreement increased from fair to moderate. Surgeons’ opinions about 3-dimensional printed models with Likert scale-type questions show positive overall results ranging from 8.3± 2.1 to 8.6 ± 1.4. Conclusion: This study has shown that the inter- and intra-observer agreement with the addition of a 3-dimensional printed model for the evaluation of the distal radius fractures of Association For Osteo synth esis/ Ortho pedic Trauma Association C type for classification, fractures morphology, and preoperative planning tends to increase; however, improvements for an inter-observer agreement remain fair. Level of Evidence: Level III Diagnostic Study Cite this article as: Grinčuk A, Makulavičius A, Porvaneckas N, Ryliškis S, Šatkauskas I, Uvarovas V. The role of 3-dimensional printed models in the management of the distal radius fractures. Acta Orthop Traumatol Turc., 2023;57(1):40-45.
Introduction: The selection of an appropriate PROM is a crucial aspect in assessing outcomes. Questionnaires that have not been designed or validated for a paediatric population are routinely used. Using a questionnaire requires translation, cultural adaptation, and testing the psychometric properties of the translated questionnaire. There is no applicable questionnaire in our country for children with knee-specific conditions in sports orthopaedics. Therefore, this study aims to translate, culturally adapt, and assess the psychometric properties of the Paediatric IKDC (Pedi-IKDC) questionnaire within the Lithuanian paediatric population. Methods: The translation was conducted in accordance with international standards. Patients aged 11–17 years with various knee disorders participated in three surveys and completed the Pedi-IKDC, Lysholm, and PedsQL questionnaires. Interviews with patients following the translation process, in addition to floor and ceiling effects, were used to assess content validity. Cronbach alpha (α) statistics and the intraclass correlation coefficient (ICC) were applied to measure internal consistency and reproducibility, respectively. The standard error of measurement (SEM) and smallest detectable change (SDC) were calculated to assess reliability. Pearson correlations were calculated between Pedi-IKDC and Lysholm PedsQL scores to determine criteria validity. The effect size (ES) and standardised response mean (SRM) were calculated to assess the responsiveness to change. Results: Cronbach’s alpha (α) was 0.91 for the total score, 0.75 for symptoms, and 0.92 for the sport/function component. The ICC for overall scores was 0.98, with each question ranging from 0.87 to 0.98. The SEM was 2.97, and the SDC was 8.23. Lysholm and PedsQL physical functioning domain scores had moderate correlations (0.8 > r > 0.5), and the overall PedsQL score had a weak correlation (0.5 > r > 0.2) to the Pedi-IKDC score. The floor and ceiling effects were 3.3% and 1.6%, respectively. The SRM was 1.72 and the ES was 1.98. Conclusions: The Lithuanian Pedi-IKDC version is an appropriate evaluation instrument for assessing outcomes in children with knee disorders. All of the psychometric features produced acceptable results.