A case study was conducted to evaluate the SO2 emission reduction in a power plant in Central Mexico, as a result of the shifting of fuel oil to natural gas. Emissions of criteria pollutants, greenhouse gases, organic and inorganic toxics were estimated based on a 2010 report of hourly fuel oil consumption at the “Francisco Pérez Ríos” power plant in Tula, Mexico. For SO2, the dispersion of these emissions was assessed with the CALPUFF dispersion model. Emissions reductions of > 99% for SO2, PM and Pb, as well as reductions >50% for organic and inorganic toxics were observed when simulating the use of natural gas. Maximum annual (993 µg/m3) and monthly average SO2 concentrations were simulated during the cold-dry period (152-1063 µg/m3), and warm-dry period (239-432 µg/m3). Dispersion model results and those from Mexico City’s air quality forecasting system showed that SO2 emissions from the power plant affect the north of Mexico City in the cold-dry period. The evaluation of model estimates with 24 hr SO2 measured concentrations at Tepeji del Rio suggests that the combination of observations and dispersion models are useful in assessing the reduction of SO2 emissions due to shifting in fuels. Being SO2 a major precursor of acid rain, high transported sulfate concentrations are of concern and low pH values have been reported in the south of Mexico City, indicating that secondary SO2 products emitted in the power plant can be transported to Mexico City under specific atmospheric conditions.
Worldwide, the increase in land surface temperature has been attributed to the concentration of greenhouse gases. However, there is no record of timely information that shows which types of land cover relate to major increases in surface temperature. The main aim of this paper is to identify the specific sites in a landfill where biogas is released into the atmosphere. A second objective is to try to find a spatial correlation between the concentration of methane emitted to the atmosphere with the observed surface temperature gradients. The recoverable and fugitive methane fluxes were validated with in situ information, using a LICOR gas accumulation chamber. The surface heat estimate was obtained from the Split Window algorithm, using the TIRS sensor of the Landsat 8. With data obtained in previous studies, both in situ and remote, it was possible to spatially correlate the methane flux released into the atmosphere with the temperature distribution plume within the landfill. The importance of our research is related to the continuous need for surface temperature monitoring on the planet. The use of technological tools such as the one presented here reduces the cost and execution time of environmental studies.
3 July 2018 in Australasian Journal of Engineering Education
One of the most commonly used forms of educational evaluation is by means of student surveys. In Colombia, as in all countries of Latin America, student course evaluations in higher education remain focused on teaching performance, while the results of these instruments are frequently used as an indicator (and in some cases the only indicator) of quality and effectiveness of both undergraduate and postgraduate programmes. This article argues that the teacher-centred evaluation provides insufficient information to improve the quality of higher education. Therefore, a process-based evaluation model (PBEM) is proposed for a Colombian university offering engineering programmes. The PBEM is intended to provide reliable information on teaching effectiveness, but also about other factors influencing teaching and learning such as course design. The PBEM was designed in accordance with the EIA University’s pedagogical model, which encompasses competencies, values, and key areas of transversal learning. The implementation of the instrument started in 2015. Since then, more than 2500 lecture groups have been evaluated. This article addresses some key issues and challenges related to the implementation of this evaluation model.
Despite significant progress in controlling outdoor air pollution in Mexico City over the past three decades, indoor air pollution remains largely unaddressed. This is particularly concerning because health authorities advise people to stay indoors when outdoor pollution exceeds safe limits, yet indoor concentrations can be higher. Two optical particle counters were deployed simultaneously indoors and outdoors in 38 homes across all municipalities in Mexico City. The average indoor 24 h PM2.5 concentration was 24.5 µg m−3, while PM10 concentration averaged 78.6 µg m−3 compared to outdoor averages of 20.5 µg m−3 and 72.0 µg m−3. The PM2.5/PM10 ratio was 0.3 both indoors and outdoors. Only 20% of the homes exhibited maximum outdoor PM2.5 concentrations 3.6 times higher than indoor; in 18%, indoor and outdoor levels were similar (0.8–1.2); and 60% of homes recorded indoor maxima up to nine times the outdoor peaks. Elevated indoor PM2.5 was primarily linked with cooking and, to a lesser extent, cleaning activities. Peaks in PM2.5 persisted for 4–8 h before returning to baseline. Ensuring adequate indoor ventilation is critical to maintain indoor air quality below outdoor levels and comply with WHO guidelines, highlighting the need for targeted strategies to reduce indoor exposure in urban homes.
1 January 2001 in International Journal of Environment and Pollution
Differences between Gaussian model results and observations depend highly on the individual data errors of the parameters considered in the model. For example, errors in the estimated plume rise can be partly explained by the semi-empirical character of its estimation procedures. Nevertheless, inherent data errors keep being important. A mathematical estimate of the expected plume rise error due to imprecise input data is provided for different known plume rise formulae to be used in Gaussian models. The influence of this data error in the model results is presented.