Paul C. MCAfee

Dr. Paul C. MCAfee


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2010 in Journal of Spinal Disorders & Techniques
Verified
Journal Article
Closed access
PMPaul C. MCAfee
Paul C. MCAfee
ACAndrew Cappuccino
Andrew Cappuccino
BCBryan W. Cunningham
Bryan W. Cunningham
JDJohn G. Devine
John G. Devine
FPFrank M. Phillips
Frank M. Phillips
JAJeanette E. Ahrens
Jeanette E. Ahrens
The current study of 251 consecutive 1-level anterior cervical reconstructions was undertaken to compare the incidence of dysphagia between cervical disk replacement and conventional anterior cervical fusion and instrumentation. This is a report of 251 patients from 5 investigational centers in the Food and drug Administration's prospective, randomized porous-coated motion (PCM) trial using a validated dysphagia outcomes instrument. The dysphagia data for both PCM and anterior cervical diskectomy and fusion (ACDF) patients were reviewed from 5 centers to (1) compare the severity of dysphagia, (2) compare the postoperative incidence of dysphagia, and (3) to compare the resolution of perioperative dysphagia. Dysphagia and dysphonia after anterior surgical approaches to the cervical spine have been previously reported. The current prospective, randomized investigation quantifies clinical dysphagia based on 3 criteria-severity, incidence, and resolution—in a time-course evaluation. Patients between 18 and 65 years with 1-level symptomatic cervical radiculopathy and/or myelopathy for progressive neurologic symptoms, were randomized to undergo anterior decompression and PCM arthroplasty (N=151) or ACDF (control) (N=100). Patients self-reported dysphagia severity using the Bazaz scale preoperatively and at follow-up. The Bazaz scale has 4 classes of severity based upon the problems with swallowing that the patient has with both liquids and solids. The Bazaz results demonstrate that although both the PCM and ACDF groups exhibited an initial postoperative problem with swallowing, the PCM group continued to improve with increasing time after implantation, whereas the ACDF only improved minimally. The PCM treatments indicated significantly lower incidence of dysphagia at 3 and 12 months postoperatively compared with ACDF controls (P<0.05). An increase in dysphagia severity at either the 6-week or 3-month follow-up visit was reported in 35 (42%) PCM and 29 (64%) ACDF subjects. Long-term resolution of these symptoms was noted in 74% (26/35) of the PCM subjects as compared with 41.4% (12/29) of the ACDF subjects (P=0.015). In a prospective randomized clinical study the incidence of postoperative dysphagia and the long-term resolution of the dysphagia was greatly improved in the PCM group compared with the instrumented ACDF control group.

1 May 2007 in Spine
Verified
Journal Article
Closed access
LPLuiz Pimenta
Luiz Pimenta
PMPaul C. MCAfee
Paul C. MCAfee
ACAndy Cappuccino
Andy Cappuccino
BCBryan W. Cunningham
Bryan W. Cunningham
RDRoberto Diaz
Roberto Diaz
ECEtevaldo Coutinho
Etevaldo Coutinho
Class 2 level of evidence: This is a prospective, consecutive series of 229 prosthetic implantations that were concurrently enrolled between single-level versus multilevel cervical arthroplasty comprising an FDA Pilot Study. This study investigated multilevel cervical disc replacement in relation to single-level cervical arthroplasty to find if the same reduction in clinical success would occur with this alternative treatment. Usually, the clinical outcomes of instrumented cervical fusions deteriorate as the number of vertebral levels of involvement increases. A total of 229 patients presented with cervical herniated nucleus pulposus, cervical spondylosis, and/or adjacent segment disease with cervical radiculopathy or myelopathy. Following anterior cervical neurologic decompression seventy-one patients required porous coated motion (PCM) cervical arthroplasties from C3–C4 to C7–T1 (Group S, single level). Sixty-nine patients underwent 158 multilevel PCM cervical arthroplasties (Group M, multilevel) during the same time interval, for the same indications, performed by the same surgeons under the same clinical protocol: double level, 53 cases; three levels, 12 cases: and 4 levels, 4 cases. The self-assessment outcomes instruments showed significantly more improvement for the multilevel cases. The mean improvement in the NDI for the single cases was 37.6% versus the multilevel cases mean improvement in NDI was 52.6% (P = 0.021). The difference between the two was statistically significant. The mean improvement in the VAS showed the same association: single-level mean improvement 58.4% versus the multilevel cases mean VAS improvement was 65.9%. The Odom's were also more improved for the multilevel versus the single-level group: 93.9% versus 90.5% in the excellent, good, and fair categories. The reoperation rates and serious adverse events were similar between the single-level (S = 3) to the multilevel arthroplasty (M = 2) groups. Kaplan-Meier implant survivorship analysis at 3 years for the cohort of 229 prostheses was 94.5% (confidence interval, 1.00–0.820). This prospective study of cervical arthroplasty is the first report to date showing significantly improved clinical outcomes for multilevel cervical arthroplasty compared with single-level cervical disc replacement using an FDA validated outcome instrument.

1 May 2012 in Spine
Verified
Journal Article
Closed access
PMPaul C. MCAfee
Paul C. MCAfee
CRChris Reah
Chris Reah
KGKye Gilder
Kye Gilder
LELukas Eisermann
Lukas Eisermann
BCBryan Cunningham
Bryan Cunningham
Meta-analysis of 4 prospective randomized controlled Food and Drug Administration (FDA) Investigational Device Exemption (IDE) clinical trials. To maximize the information available from 4 IDE studies by analyzing the combined outcomes of cervical arthroplasty versus fusion at 24-month follow-up. To date, 4 randomized clinical trials have been completed in the United States under FDA IDE protocols to study cervical arthroplasty. Each trial reported arthroplasty to be at least as successful as fusion controls based on noninferiority trial designs. However, sample sizes in any given trial may not be sufficient to demonstrate superiority of treatment effect. Meta-analysis enables pooling of results from comparable trials, which may lead to more precise and statistically significant estimates of treatment effect. Four cervical arthroplasty randomized clinical trials with comparable enrollment criteria and outcome measures were conducted independently by 3 separate sponsors to study the following devices: Bryan, Prestige, ProDisc-C, and PCM cervical disc replacements. A total of 1608 patients were treated across 98 investigative sites. Data were available for 1352 treated patients, of which 1226 were evaluable at 24 months. Assessments included clinical success definitions based on neck disability index, maintenance or improvement of neurological status, subsequent surgery or intervention at the index level (survivorship), and a composite score comprising these as well as serious device-related adverse events. Trial endpoint comparisons were made at 24 months postoperatively. For each endpoint, a random-effects meta-analysis was performed to compare the success rates of cervical arthroplasty with anterior cervical discectomy and fusion (ACDF). Also, supportive frequentist and Bayesian analyses were performed. The pooled primary overall success results indicated a statistically significant treatment effect favoring arthroplasty compared with ACDF. Overall success was achieved by 77.6% of the arthroplasty patients and by 70.8% of the ACDF patients (pooled odds ratio [OR]: 0.699, 95% confidence interval [CI]: 0.539–0.908, P = 0.007). The results of the individual subcomponent meta-analyses, all of which favored arthroplasty, were neck disability index success (OR: 0.786, 95% CI: 0.589–1.050, P = 0.103), neurological status (OR: 0.552, 95% CI: 0.364–0.835, P = 0.005), and survivorship (OR: 0.510, 95% CI: 0.275–0.946, P = 0.033). Only the survivorship endpoint suggested low heterogeneity. These findings suggest that cervical arthroplasty is superior to ACDF in overall success, neurological success, and survivorship outcomes at 24 months postoperatively.

1 January 2008 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
FGFred H. Geisler
Fred H. Geisler
RGRichard D. Guyer
Richard D. Guyer
SBScott L. Blumenthal
Scott L. Blumenthal
PMPaul C. MCAfee
Paul C. MCAfee
ACAndrew Cappuccino
Andrew Cappuccino
JRJohn J. Regan
John J. Regan
Object: Patient selection is perhaps the most important factor in successful lumbar surgery. In this study, the authors analyzed the clinical outcomes of patients enrolled in the CHARITÉ investigational device exemption (IDE) trial who underwent revision surgery after primary total disc replacement with CHARITÉ or an anterior lumbar interbody fusion (ALIF) with placement of a BAK cage and iliac crest autograft. This revision surgery was either a supplemental posterior lumbar fixation or a 360° fusion. Statistical analysis was conducted to compare clinical success in patients who underwent revision surgery with those who did not. Methods: The patients enrolled in the CHARITÉ IDE study were divided into 6 groups according to treatment and repeated operation status, and their Oswestry Disability Index (ODI) and visual analog scale (VAS) scores at the 2-year follow-up and at baseline were compared. The patients had received the following treatments by group: A) ALIF without reoperation; B) ALIF with conversion to 360° fusion; C) arthroplasty (randomized) without repeated operation; D) arthroplasty with supplemental posterior lumbar fixation; E) arthroplasty (nonrandomized) without repeated operation; and F) arthroplasty (nonrandomized) with supplemental posterior lumbar fixation. Outcome scores in the groups of patients who required revision surgeries (Groups B, D, and F; 23 patients) were compared with the groups that did not require revision surgery (Groups A, C, and E; 299 patients). Results: Patients who required revision surgery had a significantly lower level of clinical improvement than those who did not. The mean change in ODI score was −53.0% in Groups A, C, and E, but just −12.7% in Groups B, D, and F (p < 0.0001). The mean change in VAS score was −59.1% in Groups A, C, and E, compared to −23.4% in Groups B, D, and F (p < 0.0001). No significant differences were identified in analyzing absolute change in scores and the percentage change. A comparison of outcomes in patients who had undergone arthroplasty without reoperation (Groups C and E) with all patients who had undergone revision surgery (Groups B, D, and F) demonstrated similar results (p < 0.0001). Conclusions: The 7.1% of patients who underwent a secondary stabilization procedure had poor clinical improvement. This finding may indicate that if the alternative treatment had been the initial treatment, these patients would not have benefited, and further implies a 7.1% rate of imprecision in preoperative evaluation.

1 February 2010 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
BCBryan W. Cunningham
Bryan W. Cunningham
NHNianbin Hu
Nianbin Hu
CZCandace M. Zorn
Candace M. Zorn
PMPaul C. MCAfee
Paul C. MCAfee
Object: Using a synthetic vertebral model, the authors quantified the comparative fixation strengths and failure mechanisms of 6 cervical disc arthroplasty devices versus 2 conventional methods of cervical arthrodesis, highlighting biomechanical advantages of prosthetic endplate fixation properties. Methods: Eight cervical implant configurations were evaluated in the current investigation: 1) PCM Low Profile; 2) PCM V-Teeth; 3) PCM Modular Flange; 4) PCM Fixed Flange; 5) Prestige LP; 6) Kineflex/C disc; 7) anterior cervical plate + interbody cage; and 8) tricortical iliac crest. All PCM treatments contained a serrated implant surface (0.4 mm). The PCM V-Teeth and Prestige contained 2 additional rows of teeth, which were 1 mm and 2 mm high, respectively. The PCM Modular and Fixed Flanged devices and anterior cervical plate were augmented with 4 vertebral screws. Eight pullout tests were performed for each of the 8 conditions by using a synthetic fixation model consisting of solid rigid polyurethane foam blocks. Biomechanical testing was conducted using an 858 Bionix test system configured with an unconstrained testing platform. Implants were positioned between testing blocks, using a compressive preload of −267 N. Tensile load-to-failure testing was performed at 2.5 mm/second, with quantification of peak load at failure (in Newtons), implant surface area (in square millimeters), and failure mechanisms. Results: The mean loads at failure for the 8 implants were as follows: 257.4 ± 28.54 for the PCM Low Profile; 308.8 ± 15.31 for PCM V-Teeth; 496.36 ± 40.01 for PCM Modular Flange; 528.03± 127.8 for PCM Fixed Flange; 306.4 ± 31.3 for Prestige LP; 286.9 ± 18.4 for Kineflex/C disc; 635.53 ± 112.62 for anterior cervical plate + interbody cage; and 161.61 ± 16.58 for tricortical iliac crest. The anterior plate exhibited the highest load at failure compared with all other treatments (p < 0.05). The PCM Modular and Fixed Flange PCM constructs in which screw fixation was used exhibited higher pullout loads than all other treatments except the anterior plate (p < 0.05). The PCM VTeeth and Prestige and Kineflex/C implants exhibited higher pullout loads than the PCM Low Profile and tricortical iliac crest (p < 0.05). Tricortical iliac crest exhibited the lowest pullout strength, which was different from all other treatments (p < 0.05). The surface area of endplate contact, measuring 300 mm2 (PCM treatments), 275 mm2 (Prestige LP), 250 mm2 (Kineflex/C disc), 180 mm2 (plate + cage), and 235 mm2 (tricortical iliac crest), did not correlate with pullout strength (p > 0.05). The PCM, Prestige, and Kineflex constructs, which did not use screw fixation, all failed by direct pullout. Screw fixation devices, including anterior plates, led to test block fracture, and tricortical iliac crest failed by direct pullout. Conclusions: These results demonstrate a continuum of fixation strength based on prosthetic endplate design. Disc arthroplasty constructs implanted using vertebral body screw fixation exhibited the highest pullout strength. Prosthetic endplates containing toothed ridges (≥ 1 mm) or keels placed second in fixation strength, whereas endplates containing serrated edges exhibited the lowest fixation strength. All treatments exhibited greater fixation strength than conventional tricortical iliac crest. The current study offers insights into the benefits of various prosthetic endplate designs, which may potentially improve acute fixation following cervical disc arthroplasty.

1 September 2010 in Spine
Verified
Journal Article
Closed access
RKRyan M. Kretzer
Ryan M. Kretzer
NHNianbin Hu
Nianbin Hu
JKJun Kikkawa
Jun Kikkawa
IGIra M. Garonzik
Ira M. Garonzik
GJGeorge I. Jallo
George I. Jallo
BCBryan W. Cunningham
Bryan W. Cunningham
An in vitro cadaveric biomechanical study. To determine the stability of translaminar screws compared to pedicle screws at T1-T2 for constructs bridging the cervicothoracic junction. Instrumented fixation of the cervicothoracic junction is challenging both biomechanically, due to the transition from the mobile cervical to the rigid thoracic spine, and technically, due to the anatomic constraints of the T1-T2 pedicles. For these reasons, an alternate fixation technique at T1-T2 that combines ease of screw insertion and a favorable safety profile with biomechanical stability would be clinically beneficial. A 6-degree of freedom spine simulator was used to test multidirectional flexibility in 8 human cadaveric specimens. Flexion, extension, lateral bending, and axial rotation were tested in the intact condition, followed by destabilization via a simulated 2-column injury at C7-T1. Specimens were reconstructed using C5-C6 lateral mass screws and either translaminar or pedicle screws placed at T1, followed by caudal extension to T2. A 3-column injury at C7-T1 was then performed and specimens were tested using a posterior only approach with either translaminar or pedicle screws placed at T1 and T1-T2. Finally, anterior fixation at C7-T1 was added and multidirectional flexibility testing performed as previously described. Following a 2-column injury at C7-T1, there were no significant differences in segmental flexibility at C7-T1 between translaminar and pedicle screw fixation when placed at T1-T2 (P>0.05). For a 3-column injury treated posteriorly, translaminar screws at T1-T2 provided increased flexibility compared to pedicle screws in flexion/extension (P0.05). Translaminar screws in the upper thoracic spine offer similar stability to pedicle screw fixation for constructs bridging the cervicothoracic junction. Small differences in range of motion must be weighed clinically against the potential benefits of translaminar screw insertion at T1-T2.