Andrew Nalley

Prof. Andrew Nalley

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
ZLZekai Liu
Zekai Liu
Qi Yong Hemis AiQi Yong Hemis Ai
Qi Yong Hemis Ai
AYAndy Wai Kan Yeung
Andy Wai Kan Yeung
RTRay Tanaka
Ray Tanaka
ANAndrew Nalley
Andrew Nalley
Kuo Feng HungKuo Feng Hung
Kuo Feng Hung
Objectives: The aim of this study was to evaluate the performance of GPT-4o in identifying nine common dental conditions on panoramic radiographs, both overall and at specific tooth sites, and to assess whether the use of different tooth numbering systems (FDI and Universal) in prompts would affect its diagnostic accuracy. Methods: Fifty panoramic radiographs exhibiting various common dental conditions including missing teeth, impacted teeth, caries, endodontically treated teeth, teeth with restorations, periapical lesions, periodontal bone loss, tooth fractures, cracks, retained roots, dental implants, osteolytic lesions, and osteosclerosis were included. Each image was evaluated twice by GPT-4o in May 2025, using structured prompts based on either the FDI or Universal tooth numbering system, to identify the presence of these conditions at specific tooth sites or regions. GPT-4o responses were compared to a consensus reference standard established by an oral-maxillofacial radiology team. GPT-4o’s performance was evaluated using balanced accuracy, sensitivity, specificity, and F1 score both at the patient and tooth levels. Results: A total of 100 GPT-4o responses were generated. At the patient level, balanced accuracy ranged from 46.25% to 98.83% (FDI) and 49.75% to 92.86% (Universal), with the highest accuracies for dental implants (92.86–98.83%). F1-scores and sensitivities were highest for implants, missing, and impacted teeth, but zero for caries, periapical lesions, and fractures. Specificity was generally high across conditions. Notable discrepancies were observed between patient- and tooth-level performance, especially for implants and restorations. GPT-4o’s performance was similar between using the two numbering systems. Conclusions: GPT-4o demonstrated superior performance in detecting dental implants and treated or restored teeth but inferior performance for caries, periapical lesions, and fractures. Diagnostic accuracy was higher at the patient level than at the tooth level, with similar performances for both numbering systems. Future studies with larger, more diverse datasets and multiple models are needed.

1 January 2022 in Case Reports in Dentistry
Verified
Journal Article
Open access
PDF file
TETaylor Ellingsen
Taylor Ellingsen
ANAndrew Nalley
Andrew Nalley
DODolphine Oda
Dolphine Oda
TDThomas B. Dodson
Thomas B. Dodson
PLPeggy Lee
Peggy Lee
Osteoblastoma and osteoid osteoma are rare benign neoplasms of the jaws. We reviewed current literature surrounding the ongoing debate over similarities and differences of osteoblastoma and osteoid osteoma and present two cases. Both cases are well‐demarcated mixed radiodensity mandibular lesions with histological features of osteoblastoma. They exhibit, however, distinctly unique and contrasting clinical and imaging characteristics suggesting that the first case is osteoblastoma and the second is osteoid osteoma. The first case of a 37‐year‐old male presents with a large, expansile lesion at posterior mandible, surrounded by a thick sclerotic band. Unusual features include significant buccal/lingual expansion, extensive new bone apposition, and soft tissue edema in the masseter muscle. This is in contrast to the second case of a much smaller lesion in a 17‐year‐old male with history of recent third molar extraction in the left posterior mandible. In this case, CT imaging revealed a circular, nonexpansile lesion with a sclerotic border surrounded by a radiolucent rim. Both patients underwent surgical excision of the lesion with extraction of the adjacent tooth. We discuss herein the distinct clinical and imaging features.

13 June 2026 in Insights into Imaging
Verified
Journal Article
Open access
ANAndrew Nalley
Andrew Nalley
MYMadeline Yon
Madeline Yon
KHKuo Feng Hung
Kuo Feng Hung
AYAndy Wai Kan Yeung
Andy Wai Kan Yeung
GLGang Li
Gang Li
Qi Yong Hemis AiQi Yong Hemis Ai
Qi Yong Hemis Ai
Objectives: This study aimed to identify and synthesize imaging findings in the temporomandibular joint (TMJ) complex following radiation therapy (RT) for head and neck cancer (HNC). Materials and methods: A systematic search of five databases retrieved studies reporting post-RT imaging of TMJ structures. Extracted data included patient demographics, RT dose and technique, imaging modality, imaging changes and clinical findings. Risk of bias was assessed using ROBINS-I V2 (Risk of bias in non-randomized studies—of interventions, version 2). Results: Eleven retrospective studies (282 patients; mean age 52.7 years; RT dose 30–110 Gy) were included. Post-RT analysis was evaluated by imaging modalities of MRI (7 studies), CT (4), US (1), and panoramic images (1). The most commonly described structural changes in the muscles of mastication included MRI signal abnormalities (43 patients), atrophy (20 patients) and hypertrophy (20 patients), while condylar changes included erosion (11 patients), surface irregularity (12 patients) or sclerosis (6 patients). Trismus was identified in 126 patients (44.7%). No study described changes to the glenoid fossa or articular eminence or direct osteoradionecrosis (ORN) of TMJ structures. All studies exhibited moderate to critical risk of bias, limiting the certainty of associations. Conclusions: RT can induce structural changes across TMJ components detectable on imaging, which may contribute to trismus and functional impairment. Current evidence is limited, heterogeneous and retrospective, underscoring the need for prospective studies with standardized imaging and clinical correlation. Key Points: Radiation therapy for head and neck cancer can affect jaw structures. Imaging shows changes in muscles and joints that are involved with chewing and mouth opening. These changes may lead to trismus (difficulty opening the mouth). Nearly half of patients in reviewed studies experienced this condition, impacting daily life. Current evidence is limited and inconsistent. Prospective studies with standardized imaging approaches are needed to further clarify radiation-related TMJ changes.

18 May 2026 in The Journal of the American Dental Association
Verified
Journal Article
Closed access
ANAndrew Nalley
Andrew Nalley
RTRay Tanaka
Ray Tanaka
AYAndy Wai Kan Yeung
Andy Wai Kan Yeung

22 March 2025 in International Dental Journal
Verified
Journal Article
Open access
AYAndy Wai Kan Yeung
Andy Wai Kan Yeung
ANAndrew Nalley
Andrew Nalley
Kuo Feng HungKuo Feng Hung
Kuo Feng Hung
AOAnne Caroline Oenning
Anne Caroline Oenning
RTRay Tanaka
Ray Tanaka
Cone Beam Computed Tomography (CBCT) has become a crucial imaging tool in modern dentistry. At present, a review does not exist to provide comprehensive understanding of the technological advancements and the entities driving the innovations of CBCT. This study aimed to analyse the patent records associated with CBCT technology, to gain valuable insights into the trends and breakthroughs, and identify key areas of focus from manufacturers. The online patent database called The Lens was accessed on 3 January 2025 to identify relevant patent records. A total of 706 patent records were identified and analysed. The majority of over 700 CBCT patents was contributed by CBCT manufacturers. The United States was the jurisdiction with most patent records, followed by Europe and China. Some manufacturers hold patent records for common features of CBCT systems, such as motion artifact correction, metal artifact reduction, reconstruction of panoramic image based on 3D data, and incorporation of artificial intelligence. Patent analysis can offer valuable insights into the development and advancement of CBCT technology, and foster collaboration between manufacturers, researchers, and clinicians. The advancements in CBCT technology, as reflected by patent trends, enhance diagnostic accuracy and treatment planning. Understanding these technological innovations can aid clinicians in selecting the most effective imaging tools for patient care.

8 July 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
AYAndy Wai Kan Yeung
Andy Wai Kan Yeung
RTRay Tanaka
Ray Tanaka
Kuo Feng HungKuo Feng Hung
Kuo Feng Hung
VVVarut Vardhanabhuti
Varut Vardhanabhuti
ANAndrew Nalley
Andrew Nalley
Objectives: We aimed to explore whether incorporating a deliberate error-based learning activity, adapted from error management training (EMT), could enhance undergraduate dental students’ understanding of common intra-oral radiographic faults and their phantom-head imaging performance. Methods: This randomized two-arm educational study involved Year 2 dental undergraduates who completed pre- and post-intervention phantom-head imaging and a short multiple-choice test on radiographic errors. Students were allocated either to a brief, slide-based teaching session on imaging faults (conventional group) or to a hands-on activity in which they intentionally produced and corrected faulty images under supervision (EMT group). Main outcomes included MCQ scores, confidence ratings, overall imaging performance (percentage of maximum possible score), and distribution of diagnostic image quality categories. Two-sample t tests were used to check for inter-group differences in the change in the post–pre numerical scores. The Cochran–Mantel–Haenszel (CMH) linear-by-linear test was used to check for inter-group differences in the change in image distribution by diagnostic quality before and after the intervention. Results: Eighty-seven students contributed a total of 735 radiographs. Both groups showed improvements in MCQ scores and confidence within groups. Diagnostic acceptability of student radiographs was already high at baseline and remained so afterwards, with no significant differences between groups in MCQ gains, confidence changes, imaging scores, or shifts in diagnostic image quality distributions. Conclusions: Although the single, short EMT-style activity did not outperform conventional teaching on immediate outcomes, the study demonstrates that deliberate error-based learning is feasible in a pre-clinical radiography setting and well-received by students. The findings also help to clarify the circumstances under which EMT is most likely to yield benefits, suggesting that longer or more structured EMT sessions, particularly those involving metacognitive scaffolding or more challenging imaging scenarios, may be needed before performance differences can emerge.