Hikaru Takahashi

Dr. Hikaru Takahashi

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1998 in Mycoses
Verified
Journal Article
Closed access
PDF file
YNY. Nakamura
Y. Nakamura
RKRui Kano
Rui Kano
HSH. Sato
H. Sato
SWS. Watanabe
S. Watanabe
HTHikaru Takahashi
Hikaru Takahashi
AHA. Hasegawa
A. Hasegawa

1 January 1992 in The Nishinihon Journal of Dermatology
Verified
Journal Article
Closed access
HTHikaru Takahashi
Hikaru Takahashi

1 January 1992 in The Nishinihon Journal of Dermatology
Verified
Journal Article
Closed access
HTHikaru Takahashi
Hikaru Takahashi


Verified
Journal Article
Open access
PDF file
RTRyo Takeyama
Ryo Takeyama
Yoshikane YamauchiYoshikane Yamauchi
Yoshikane Yamauchi
SKShinya Kohmaru
Shinya Kohmaru
SMShizuka Morita
Shizuka Morita
HTHikaru Takahashi
Hikaru Takahashi
YSYukinori Sakao
Yukinori Sakao
Objectives: This study was aimed to identify risk factors for persistent air leak after chest tube placement for secondary spontaneous pneumothorax and to determine the optimal timing of treatment. Methods: We retrospectively analyzed 221 cases of secondary spontaneous pneumothorax in patients aged ≥50 years who were treated with chest tube drainage. Patients were categorized into the observation group or additionally treated group based on whether they received interventional treatment beyond chest tube drainage. Air leak resolution patterns were analyzed using hazard function analysis. Risk factors were evaluated using univariate and multivariate analyses. Results: Hazard function analysis revealed that the probability of air leak resolution decreased by approximately 50% within the first 5 days after the initiation of chest tube drainage, with only 33% of cases resolving by day 7. Beyond days 7–10, resolution probability stabilized at a minimal level. Multivariate analysis identified previous pneumothorax history (HR: 0.422, p = 0.007) and low geriatric nutritional risk index (GNRI) (HR: 2.521, p < 0.001) as significant independent risk factors for persistent air leak. Further analysis of early resolution (within 7 days) identified female sex (HR: 0.24, p = 0.003), absence of previous pneumothorax (HR: 0.21, p = 0.003), and higher GNRI values (HR: 1.04, p = 0.008) as positive predictors. Conclusions: Risk stratification based on pneumothorax history and nutritional status enables the optimization of the timing of intervention for persistent air leak. We recommend considering additional treatment between days 7 and 10 of chest tube drainage, with earlier intervention for high-risk patients. This approach may improve patient outcomes while avoiding unnecessarily prolonged conservative management.

25 September 2025 in Cancers
Verified
Journal Article
Open access
PDF file
TNTomoki Nishida
Tomoki Nishida
Yuichi SaitoYuichi Saito
Yuichi Saito
TTTakeshi Takata
Takeshi Takata
SMShizuka Morita
Shizuka Morita
RTRyo Takeyama
Ryo Takeyama
YSYukinori Sakao
Yukinori Sakao
Background/Objectives: Although surgeries employing cone-beam computed tomography (CBCT) for small lung lesions have been reported, the association between CBCT scan frequency and patient radiation exposure remains unclear. This study aimed to investigate patient radiation doses from CBCT during thoracic surgeries, and the patient radiation doses were compared with those from other preoperative marking methods. Methods: This multicenter prospective study included 81 patients who underwent surgery for small lung lesions requiring marking between January 2021 and June 2024 at three institutions. CBCT-guided surgeries involved the use of metal clips in a hybrid operating room with 1–4 scans, depending on the lesion. For other preoperative marking methods, hook-wire or virtual-assisted lung mapping (VAL-MAP) was used. Patient radiation doses were measured using wearable dosimeters at five anterior thorax sites, and the total dose was compared across methods. Results: The study included 81 patients: CBCT (n = 61), VAL-MAP (n = 10), and hook-wire (n = 10). CBCT cases were distributed as follows: single scan (n = 10), double scans (n = 34), triple scans (n = 15), and quadruple scans (n = 2). The radiation doses were 86.9 ± 61.7 mGy for hook-wire, 39.8 ± 27.5 mGy for VAL-MAP, and 11.0 ± 6.5 mGy for single-scan CBCT, 17.3 ± 7.8 mGy for double scans, 23.1 ± 14.0 mGy for triple scans, and 22.7 ± 0.1 mGy for quadruple scans. Although radiation exposure increased with more CBCT scans, performing up to triple scans resulted in significantly lower exposure compared to other methods. Conclusions: Intraoperative CBCT is a feasible and safe technique for identifying small lung lesions, providing lower radiation exposure compared to other preoperative localization methods.