Megan Elizabeth Johnson

Dr. Megan Elizabeth Johnson

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2023 in Spine Deformity
Verified
Journal Article
Closed access
PDF file
AJAdam A. Jamnik
Adam A. Jamnik
ADAnne-Marie Datcu
Anne-Marie Datcu
ELEmily Lachmann
Emily Lachmann
SPSahiti D. Patibandla
Sahiti D. Patibandla
DTDavid Thornberg
David Thornberg
MJMegan Elizabeth Johnson
Megan Elizabeth Johnson

1 January 2020 in JBJS Essential Surgical Techniques
Verified
Journal Article
Closed access
AEAnthony Egger
Anthony Egger
JMJoshua Murphy
Joshua Murphy
MJMegan Elizabeth Johnson
Megan Elizabeth Johnson
PHPooya Hosseinzadeh
Pooya Hosseinzadeh
CLCraig Louer
Craig Louer
Background: Most pediatric tibial shaft fractures (75%) 1 can be treated nonoperatively; however, unstable and open fractures require surgical intervention. Titanium elastic nails have become a popular technique for fixation of pediatric tibial shaft fractures. They act as internal splints that impart relative stability to the fracture, promoting callus formation at the fracture site 2 . Description: After the patient is placed in the supine position, the proximal tibial physis is marked using fluoroscopy. An anteromedial and anterolateral incision are made distal to the physis. Entry holes are created in the proximal part of the tibia, and appropriately sized titanium nails are introduced into the bone. Nail size should be 40% of the width of the canal, yielding 80% canal fill when 2 nails are used. The nails are prebent into a gentle C-shape to increase cortical contact at the apex so that 3-point fixation is achieved. The nails are passed to the fracture site, and the fracture is then reduced. The nails are then passed across the fracture site and stopped proximal to the distal tibial physis. The nails are then cut and tamped distally until there is just a short portion of nail left out of the proximal part of the tibia so that the nails can be removed once the fracture is healed. The wounds are then closed, and postoperative immobilization is applied. Alternatives: Many pediatric tibial shaft fractures can be treated with closed reduction and cast immobilization. Open fractures, or fractures that fail nonoperative management, can be treated with external fixation, open reduction and internal fixation (ORIF), or intramedullary stabilization 3 . Rationale: Anatomic reduction and fracture compression can be achieved with ORIF; however, a drawback to this technique is the lack of soft-tissue coverage in the diaphyseal area of the tibia, which can lead to infection and wound-healing problems 4 . External fixation has traditionally been the technique of choice for open tibial fractures; however, with the ability to use flexible tibial nails in both open and closed tibial fractures, external fixation is now reserved for open fractures with large soft-tissue defects or in fractures with segmental bone loss. Intramedullary flexible nailing can be used in both open and closed tibial fractures, provides excellent fracture fixation, and utilizes incisions that are more cosmetically appealing to patients 5,6 . Expected Outcomes: Outcomes following flexible nailing for pediatric tibial fractures are excellent. In a study of 19 patients undergoing flexible nailing for tibial shaft fractures, 18 had excellent or satisfactory results 7 . Compared with patients who had external fixation, those treated with flexible nails had less pain, shorter time to union, and better functional outcomes 2 . Compared with patients treated with ORIF, those who underwent flexible intramedullary nailing spent less time in the operating room and had lower rates of wound complications 4 . In the immediate postoperative period, clinicians should be aware of the risk of compartment syndrome, particularly in patients with high-energy injuries, older patients (>14 years old), and heavier patients (>50 kg) 8 . There is also an increased risk of soft-tissue irritation and fracture malunion in heavier patients treated with flexible nails 9,10 . Important Tips: Nail size should be 80% of the canal diameter (e.g., two 4.0-mm nails should be chosen for a canal that measures 10 mm). Nails should be properly contoured to avoid corticotomy of the far cortex during insertion; apex of the bend should be positioned at the level of the fracture. During insertion, leave room to advance nails further after they are cut proximally. Do not bury the proximal nail tips beneath the cortex as extraction will be difficult. Ensure that the ends of the nails are not lying up against the proximal tibial physis as this may cause premature growth arrest.

23 May 2025 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
WHWilliam J. Hadden
William J. Hadden
EFEvan Fene
Evan Fene
LKLydia Klinkerman
Lydia Klinkerman
YMYuhan Ma
Yuhan Ma
CJChanhee Jo
Chanhee Jo
MJMegan Elizabeth Johnson
Megan Elizabeth Johnson
Background: Patients with apical spinal cord deformity have been shown to be at a greater risk for intraoperative neuromonitoring (IONM) alerts when undergoing posterior spinal instrumented fusion (PSF) for adolescent idiopathic scoliosis (AIS). The use of intraoperative traction during deformity correction has also been associated with an increased risk of IONM alerts. With use of the Spinal Cord Shape Classification System (SCSCS), we investigated the interaction between spinal cord type and the use of intraoperative traction and their impact on IONM alerts during the surgical correction of AIS. Methods: A total of 441 consecutive patients who underwent PSF or combined PSF plus anterior spinal fusion (ASF) for AIS between 2003 and 2022 were retrospectively reviewed. Those with major thoracic curves of ≥70° and available preoperative magnetic resonance images (MRIs) were included. Charts were reviewed for IONM alerts and the use of intraoperative traction. Spinal cord morphology was determined using the SCSCS. A multivariable regression model was used to assess the risk factors for an IONM alert. Results: Preoperative MRIs were available for 102 patients. Type-3 cords were present in 15 (14.7%) of the 102 patients. Intraoperative traction was used in 15 (14.7%) of the 102 patients, including 5 with type-3 cords. Patients with type-3 cords were more likely to have an IONM alert than those with type-1 or 2 cords (40.0% [type 3] versus 12.6% [type 1 or 2]; odds ratio [OR], 4.60; 95% confidence interval [CI], 1.34 to 15.53). No such difference was observed between patients with type-1 cords and those with type-2 cords (12.5% and 12.7%, respectively; p > 0.9999). All patients with type-3 cords placed in intraoperative traction experienced IONM alerts, whereas only 10% of patients with type-3 cords not placed in traction experienced such alerts (p = 0.002). Multivariable regression modeling revealed intraoperative traction to be the only independent risk factor for an IONM alert (OR, 9.37; 95% CI, 2.47 to 38.24). Conclusions: This study demonstrated that 14.7% of patients with AIS and curves of ≥70° had a type-3 cord. Intraoperative traction carried a ninefold increased risk of an IONM alert. When intraoperative traction is used for type-3 cords, surgeons should expect IONM alerts to occur. The SCSCS can be condensed into 2 groups for a pediatric population. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

31 August 2022 in Journal of Pediatric Orthopaedics
Verified
Journal Article
Closed access
YLYing Li
Ying Li
RSRyan M. Sanborn
Ryan M. Sanborn
DCDanielle Cook
Danielle Cook
KBKeith Baldwin
Keith Baldwin
ABAllan C. Beebe
Allan C. Beebe
C(Children’s Orthopaedic Trauma and Infection Consortium for Evidence-Based Studies (CORTICES)
Children’s Orthopaedic Trauma and Infection Consortium for Evidence-Based Studies (CORTICES)
Background: There is limited information on the presentation and management of upper extremity septic arthritis (UESA) in children. Our purpose was to report on the characteristics and short-term treatment outcomes of pediatric UESA from a multicenter database. Methods: Patients with UESA were identified from a multicenter retrospective musculoskeletal infection database. Demographics, laboratory tests, culture results, number of surgeries, and complications were collected. Results: Of 684 patients with septic arthritis (SA), 68 (10%) patients had UESA. Septic arthritis was most common in the elbow (53%), followed by the shoulder (41%) and wrist (4%). The median age at admission was 1.7 years [interquartile range(IQR, 0.8-8.0 y)] and 66% of the cohort was male. Blood cultures were collected in 65 (96%) patients with 23 (34%) positive results. Joint aspirate and/or tissue cultures were obtained in 66 (97%) patients with 49 (72%) positive results. Methicillin-sensitive Staphylococcus aureus (MSSA) was the most common causative organism overall, but Streptococcus was the most common pathogen in the shoulder. Sixty-six (97%) patients underwent irrigation and debridement, with 5 (7%) patients requiring 2 surgeries and 1 patient (1%) requiring 3 surgeries. The median length of stay was 4.9 days (IQR, 4.0-6.3 d). Thirty-one (46%) children had adjacent musculoskeletal infections and/or persistent bacteremia. No patients experienced venous thromboembolism, and 4 patients with associated osteomyelitis experienced a musculoskeletal complication (3 avascular necrosis, 1 pathologic fracture). One child had re-admission and 3 children with associated osteomyelitis had a recurrence of UESA. Comparison between elbow and shoulder locations showed that children with septic arthritis of the shoulder were younger (4.6 vs. 1.0 y, P=0.001), and there was a difference in minimum platelet count (280 vs. 358 ×109 cells/L, P=0.02). Conclusions: UESA comprises 10% of cases of septic arthritis in children. The elbow is the most common location. Shoulder septic arthritis affects younger children. MSSA is the most common causative organism in UESA, but Streptococcus is common in shoulder septic arthritis. Irrigation and debridement result in excellent short-term outcomes with a low complication rate. Re-admissions and repeat surgical interventions are rare. Level of Evidence: Level IV, prognostic.

5 May 2023 in Journal of the Pediatric Orthopaedic Society of North America
Verified
Journal Article
Open access
PDF file
VMVeronica Meneses
Veronica Meneses
KCKelsie Coe
Kelsie Coe
ACArturo Corrales
Arturo Corrales
JBJaysson Brooks
Jaysson Brooks
WHWhitney Herge
Whitney Herge
MJMegan Elizabeth Johnson
Megan Elizabeth Johnson
Transgender and gender-expansive youth may experience barriers to healthcare due to stress and anxiety associated with accessing healthcare coupled with a lack of awareness by providers of best practices for treating this population. The pediatric orthopaedic community has an opportunity to improve relationships and outcomes for transgender patients by understanding the distinctive qualities of this population and how to best support these patients via the provision of gender-affirming care. By following best practices for gender-affirming care, pediatric orthopaedic providers are uniquely positioned to provide affirming, supportive care for transgender patients within their practices, which may ultimately impact patient outcomes and patient satisfaction. Gender-affirming care should begin the moment the patient enters the healthcare facility, continue through all perioperative and follow-up care, and should be practiced by all members of a multidisciplinary care team. Synergizing the expertise of psychologists, developmental and behavioral pediatricians, and orthopaedic surgeons, this article offers best practices at each step in the care pathway for providers to consider.

1 January 2021 in JBJS Essential Surgical Techniques
Verified
Journal Article
Closed access
JMJoshua S. Murphy
Joshua S. Murphy
RKRyan Koehler
Ryan Koehler
MJMegan Elizabeth Johnson
Megan Elizabeth Johnson
PHPooya Hosseinzadeh
Pooya Hosseinzadeh
Background: Flexible intramedullary nailing is performed for femoral fractures in pediatric patients who may be too large for spica cast immobilization but who have substantial growth remaining and who are not a candidate for rigid intramedullary nailing. Flexible nailing allows the surgeon to obtain correct alignment of the femur fracture so as to allow for healing without a lower extremity deformity. Description: The patient is positioned on a radiolucent table, flexible nails are chosen according to the diameter of the medullary canal, medial and lateral incisions are made along the distal aspect of the thigh, and access to the canal is obtained with use of a drill-bit of the appropriate size. Flexible nails are contoured to place the apex at the location of the fracture site and then passed 1 at a time up to the fracture through the medial and lateral corticotomies. Fracture reduction is obtained, and the nails are passed across the fracture 1 at a time. Leave a small amount of nail prominent at the entry site; the nails are then cut and advanced with a tamp. Alternatives: Spica cast immobilization, rigid intramedullary nailing, external fixation, and submuscular plating. Rationale: Flexible nailing provides relative stability of a femoral fracture similar to external fixation, submuscular plating, and rigid nailing; however, external fixators come with pin-track complications and infections, as well as a bulky device external to the thigh. Submuscular plating is beneficial for length-unstable fractures but is a longer procedure and implant removal is more difficult. In an older child with growth remaining, a rigid femoral nail is an option with similar outcomes to flexible nailing; however, the implant is harder to remove. Flexible nailing provides a cosmetic incision with reliable relative fixation in length-stable fractures, and easy removal of implants with equal or even improved outcomes compared with other surgical techniques. Expected Outcomes: The outcomes of this procedure are excellent. Most pediatric femoral fractures treated with flexible nailing heal well with few complications. Angulation at the fracture site is the most common complication and is more common in fractures of the proximal or distal third of the femur 1 . Worse outcomes occur in older children and children who are heavier 1 . Outcomes are improved when flexible nailing is done in length-stable fractures; however, postoperative immobilization in a single-leg spica cast or knee immobilizer can augment fixation in fractures that are not stable. Implant irritation can occur at the insertion site; however, the implants are easy to remove once the fracture has healed. There is a substantially lower rate of malunion when stainless-steel nails (6%) are utilized compared with titanium nails (23%). Consideration should therefore be given to the use of stainless-steel nails for pediatric femoral fractures 2 . Important Tips: Use a radiolucent table with either a post or a sheet for counter-traction aids during reduction Use stainless-steel nails Pass the easier nail first Advance into the femoral neck or trochanteric apophysis Do not wrap rods around each other Cut off the machined tip of the nail and custom-contour the nail in patients with poor bone quality