Dieter De Baere

Dieter De Baere


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2017 in Sensors
Verified
Journal Article
Open access
PDF file
WDWim Devesse
Wim Devesse
DBDieter De Baere
Dieter De Baere
PGPatrick Guillaume
Patrick Guillaume
A contactless temperature measurement system is presented based on a hyperspectral line camera that captures the spectra in the visible and near infrared (VNIR) region of a large set of closely spaced points. The measured spectra are used in a nonlinear least squares optimization routine to calculate a one-dimensional temperature profile with high spatial resolution. Measurements of a liquid melt pool of AISI 316L stainless steel show that the system is able to determine the absolute temperatures with an accuracy of 10%. The measurements are made with a spatial resolution of 12 µm/pixel, justifying its use in applications where high temperature measurements with high spatial detail are desired, such as in the laser material processing and additive manufacturing fields.

21 October 2015 in Sensors
Verified
Journal Article
Open access
PDF file
MSMaria Strantza
Maria Strantza
Dimitrios AggelisDimitrios Aggelis
Dimitrios Aggelis
DBDieter De Baere
Dieter De Baere
PGPatrick Guillaume
Patrick Guillaume
DHDanny J.L. VAN HEMELRIJCK
Danny J.L. VAN HEMELRIJCK
During the last decades, structural health monitoring (SHM) systems are used in order to detect damage in structures. We have developed a novel structural health monitoring approach, the so-called “effective structural health monitoring” (eSHM) system. The current SHM system is incorporated into a metallic structure by means of additive manufacturing (AM) and has the possibility to advance life safety and reduce direct operative costs. It operates based on a network of capillaries that are integrated into an AM structure. The internal pressure of the capillaries is continuously monitored by a pressure sensor. When a crack nucleates and reaches the capillary, the internal pressure changes signifying the existence of the flaw. The main objective of this paper is to evaluate the crack detection capacity of the eSHM system and crack location accuracy by means of various non-destructive testing (NDT) techniques. During this study, detailed acoustic emission (AE) analysis was applied in AM materials for the first time in order to investigate if phenomena like the Kaiser effect and waveform parameters used in conventional metals can offer valuable insight into the damage accumulation of the AM structure as well. Liquid penetrant inspection, eddy current and radiography were also used in order to confirm the fatigue damage and indicate the damage location on un-notched four-point bending AM metallic specimens with an integrated eSHM system. It is shown that the eSHM system in combination with NDT can provide correct information on the damage condition of additive manufactured metals.

11 February 2016 in Materials
Verified
Journal Article
Open access
PDF file
MSMaria Strantza
Maria Strantza
RVReza Vafadari
Reza Vafadari
DBDieter De Baere
Dieter De Baere
BVBey Vrancken
Bey Vrancken
WPWim Van Paepegem
Wim Van Paepegem
DHDanny J.L. VAN HEMELRIJCK
Danny J.L. VAN HEMELRIJCK
Selective laser melting (SLM) is an additive manufacturing (AM) process which is used for producing metallic components. Currently, the integrity of components produced by SLM is in need of improvement due to residual stresses and unknown fracture behavior. Titanium alloys produced by AM are capable candidates for applications in aerospace and industrial fields due to their fracture resistance, fatigue behavior and corrosion resistance. On the other hand, structural health monitoring (SHM) system technologies are promising and requested from the industry. SHM systems can monitor the integrity of a structure and during the last decades the research has primarily been influenced by bionic engineering. In that aspect a new philosophy for SHM has been developed: the so-called effective structural health monitoring (eSHM) system. The current system uses the design freedom provided by AM. The working principle of the system is based on crack detection by means of a network of capillaries that are integrated in a structure. The main objective of this research is to evaluate the functionality of Ti6Al4V produced by the SLM process in the novel SHM system and to confirm that the eSHM system can successfully detect cracks in SLM components. In this study four-point bending fatigue tests on Ti6Al4V SLM specimens with an integrated SHM system were conducted. Fractographic analysis was performed after the final failure, while finite element simulations were used in order to determine the stress distribution in the capillary region and on the component. It was proven that the SHM system does not influence the crack initiation behavior during fatigue. The results highlight the effectiveness of the eSHM on SLM components, which can potentially be used by industrial and aerospace applications.

9 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MHMichaël Hinderdael
Michaël Hinderdael
ZJZoé Jardon
Zoé Jardon
MLMargot Lison
Margot Lison
DBDieter De Baere
Dieter De Baere
WDWim Devesse
Wim Devesse
PGPatrick Guillaume
Patrick Guillaume
Currently, research on structural health monitoring systems is focused on direct integration of the system into a component or structure. The latter results in a so-called smart structure. One example of a smart structure is a component with integrated strain sensing for continuous load monitoring. Additive manufacturing, or 3D printing, now also enables such integration of functions inside components. As a proof-of-concept, the Fused Deposition Modeling (FDM) technique was used to integrate a strain sensing element inside polymer (ABS) tensile test samples. The strain sensing element consisted of a closed capillary filled with a fluid and connected to an externally mounted pressure sensor. The volumetric deformation of the integrated capillary resulted in pressure changes in the fluid. The obtained pressure measurements during tensile testing are reported in this paper and compared to state-of-the-art extensometer measurements. The sensitivity of the 3D printed pressure-based strain sensor is primarily a function of the compressibility of the capillary fluid. Air- and watertightness are of critical importance for the proper functioning of the 3D printed pressure-based strain sensor. Therefore, the best after-treatment procedure was selected on basis of a comparative analysis. The obtained pressure measurements are linear with respect to the extensometer readings, and the uncertainty on the strain measurement of a capillary filled with water (incompressible fluid) is ±3.1 µstrain, which is approximately three times less sensitive than conventional strain gauges (±1 µstrain), but 32 times more sensitive than the same sensor based on air (compressible fluid) (±101 µstrain).

25 January 2016 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MHMichaël Hinderdael
Michaël Hinderdael
DBDieter De Baere
Dieter De Baere
PGPatrick Guillaume
Patrick Guillaume
Additive manufactured components have a different metallurgic structure and are more prone to fatigue cracks than conventionally produced metals. In earlier papers, an effective Structural Health Monitoring solution was presented to detect fatigue cracks in additive manufactured components. Small subsurface capillaries are embedded in the structure and pressurized (vacuum or overpressure). A crack that initiated at the component’s surface will propagate towards the capillary and finally breach it. One capillary suffices to inspect a large area of the component, which makes it interesting to locate the crack on the basis of the pressure measurements. Negative pressure waves (NPW) arise from the abrupt encounter of high pressure fluid with low pressure fluid and can serve as a basis to locate the crack. A test set-up with a controllable leak valve was built to investigate the feasibility of using NPW to localize a leak in closed tubes with small lengths. Reflections are expected to occur at the ends of the tube, possibly limiting the localization accuracy. In this paper, the results of the tests on the test set-up are reported. It will be shown that the crack could be localized with high accuracy (millimeter accuracy) which proves the concept of crack localization on basis of NPW in a closed tube of small length.

2 July 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
DBDieter De Baere
Dieter De Baere
MHMichaël Hinderdael
Michaël Hinderdael
MMMarc Moonens
Marc Moonens
ZJZoé Jardon
Zoé Jardon
MLMargot Lison
Margot Lison
PGPatrick Guillaume
Patrick Guillaume
Additive manufacturing (AM) has proven in a number of demonstrators its tremendous potential for structural components. AM has gone beyond being a prototyping process and is now firmly being explored as production process in numerous domains. The objective of the paper is to provide an overview of remaining challenges in the field of AM and structural health monitoring. A symbiotic solution, a smart structure, for some of the challenges in both fields will be presented. The development progress made in these domains by the Acoustics and Vibration Research Group (AVRG) of the Vrije Universiteit Brussel will be discussed and the future outlook.