Jingyi Cao

Dr. Jingyi Cao

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
XNXiaoping Ning
Xiaoping Ning
JCJingyi Cao
Jingyi Cao
WWWei Wang
Wei Wang
GZGuangwei Zhou
Guangwei Zhou
FYFan Yang
Fan Yang
FLFanglin Lu
Fanglin Lu
Tricuspid regurgitation (TR) has become one of the most common valve diseases. Patients with severe TR are often at high surgical mortality risk. Transcatheter tricuspid valve interventions have emerged as a promising alternative to open-heart surgery. The LuX-Valve is a novel radial force-independent transcatheter tricuspid valve replacement system. We presented here the first patient treated for symptomatic TR using the LuX-Valve replacement system in September 2018. Four-year follow-up outcomes suggested that the bioprosthesis was in normal function, with stable hemodynamics (mean transtricuspid gradient 2.55 mmHg) and the patient’s clinical symptoms were significantly improved; thus indicating that it is a safe, effective, and satisfactory case of the LuX-Valve application in treating a patient with severe TR.

16 October 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
WZWeiqiang Zhang
Weiqiang Zhang
MLMenglong Li
Menglong Li
YZYujie Zhang
Yujie Zhang
JCJingyi Cao
Jingyi Cao
FSFeng Shen
Feng Shen
YLYang Li
Yang Li
Eye blinks contaminate frontal electroencephalography (EEG), while asymmetric disturbances can cause false detections. We present a physiology-informed detector that combines waveform correlation, peak-time agreement, amplitude similarity, and symmetric-component dominance in an explicit event-verification rule. It uses two frontal channels without supervised model fitting. Evaluation on raw ZuCo 1.0 recordings included 260 eligible blocks from 12 participants, totalling 1291.61 min and 8611 eye-tracker reference intervals. Scalp and periocular pairs were evaluated separately. On the scalp pair, participant-mean precision was 0.731, recall 0.774, F1 0.734, and false positives 1.469 per minute. At fixed settings, false-positive rates were lower than with single-channel thresholding and bilateral averaging (both Holm-adjusted p = 0.005859), and remained lower than those of four rule-based controls across five perturbation conditions. Threshold-selected simple controls achieved higher precision at similar recall. Component ablations quantified the effects of the verification checks on sensitivity and false positives. The offline Python detector required a median of 2.13 ms per minute of recorded data on an Apple M1 Pro. These results establish a computationally inexpensive approach that makes blink-event decisions directly inspectable through bilateral signal measurements.

28 November 2025 in European Heart Journal
Verified
Journal Article
Closed access
JCJingyi Cao
Jingyi Cao
FSFeng Shen
Feng Shen
FLFanglin Lu
Fanglin Lu