Syuntaro Nomoto

Dr. Syuntaro Nomoto

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2018 in Dental Materials Journal
Verified
Journal Article
Open access
PDF file
YTYu Tsuyuki
Yu Tsuyuki
TSToru Sato
Toru Sato
SNSyuntaro Nomoto
Syuntaro Nomoto
MYMamoru Yotsuya
Mamoru Yotsuya
TKTeruyoshi Koshihara
Teruyoshi Koshihara
MYMasao Yoshinari
Masao Yoshinari
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies

19 January 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
MHMizuho Hirano
Mizuho Hirano
SNSyuntaro Nomoto
Syuntaro Nomoto
TSToru Sato
Toru Sato
MYMamoru Yotsuya
Mamoru Yotsuya
RHRyuichi Hisanaga
Ryuichi Hisanaga
HSHideshi Sekine
Hideshi Sekine
Layered-type zirconia disks, which offer color gradation from enamel to cervical shade, have been employed in recent years to replicate the shades of natural teeth. The layered structure is effective at replicating colors and has helped popularize monolithic zirconia restorations. However, the sintering shrinkage of zirconia is very large; thus, controlling the sintering distortion is very important. Thus, the objective of this study was to determine the influence exerted by the layered structure of the zirconia disk and the vertical milling area on the sintering distortion. An experimental fixed partial denture (FPD) was designed based on a 4-unit monolithic zirconia FPD. A single-composition (SC)-type disk with no shade and a single-composition-layered (SCL)-type disk with shade gradation were selected for this study. In particular, three milling areas, the top end of the disk (area I), vertical center (area II), and bottom end of the disk (area III), were investigated. Moreover, the sintering distortions generated by the experimental FPDs were measured. Results showed that sintering distortion in 4-unit monolithic zirconia FPDs occurred in all SC and SCL areas. Additionally, the sintering distortions were affected by the layered structure of the zirconia disks, the degree of which depended on the milling area (area I > area II > area III). Thus, when fabricating dental prosthesis using SCL zirconia disks, the milling area must be selected considering both the color adjustment and sintering distortion.

9 September 2025 in Materials
Verified
Journal Article
Open access
PDF file
MHMizuho Hirano
Mizuho Hirano
SNSyuntaro Nomoto
Syuntaro Nomoto
HSHideshi Sekine
Hideshi Sekine
Zirconia is a high-strength ceramic and has increasing importance, particularly in the field of aesthetic dentistry for crown restorations. Multi-composition-layered-type (MCL) zirconia is attracting attention as a new material that integrates high light transmittance with mechanical strength. However, there are no reports on the deformation induced by sintering in MCL zirconia. Therefore, we aimed to investigate the sintering distortion of MCL zirconia. An experimental fixed dental prosthesis (FDP) was designed based on a 4-unit monolithic zirconia FDP. A MCL with no color gradation and an MCL with color gradation were selected. Particularly, three milling areas—the top end of the disk (area I) (n = 7), vertical center (area II) (n = 7), and bottom end of the disk (area III) (n = 7)—were investigated. Moreover, sintering distortions generated by experimental FDPs were measured. Sintering distortion was detected in all areas. The direction of distortion varied by area—positive in area I, negative in area II, and approximately zero in area III—with a significant difference between areas I and II (p = 0.001). The largest absolute distortion was observed in c-MCL-A (area I); the corresponding marginal gaps were ~89.4 μm (second molar) and ~56.9 μm (first premolar), both below the clinical threshold of 120 μm.

25 September 2024 in Dental Materials Journal
Verified
Journal Article
Open access
PDF file
SNSyuntaro Nomoto
Syuntaro Nomoto
MHMizuho Hirano
Mizuho Hirano
YTYu Tsuyuki
Yu Tsuyuki
TSTakanori Sakai
Takanori Sakai
MYMamoru Yotsuya
Mamoru Yotsuya
HSHideshi Sekine
Hideshi Sekine
This study compared the effects of two surface preparation methods on two types of zirconia. Immediately prior to the placement of a monolithic zirconia crown, its morphology may be modified using a rotary cutting instrument for occlusal adjustments. The crown surface is scratched during the grinding process and, thus, requires polishing. Simplified zirconia crowns of 3Y and 5Y were fabricated and used as specimens. The surface roughness and gloss of the occlusal surfaces of specimens were measured and compared when a polishing compound was used after polishing points and when a silica-based coating was sintered. No significant differences were observed in surface roughness between 3Y and 5Y zirconia. The use of polishing compounds was effective because polishing points alone only resulted in a level of surface roughness that may cause wear on antagonist teeth. Although the silica-based coating improved surface properties, the polishing compound more effectively improved surface roughness.

1 January 2014 in The Bulletin of Tokyo Dental College
Verified
Journal Article
Open access
PDF file
SNSyuntaro Nomoto
Syuntaro Nomoto
TSToru Sato
Toru Sato
SYShuji Yoshida
Shuji Yoshida
SSShion Saito
Shion Saito
IKIsao Kamiyama
Isao Kamiyama
JTJun-Ichi Tanaka
Jun-Ichi Tanaka
Here we describe two patients in whom prostheses were applied for flap protection after buccal mucosal incision. In the first case, the patient was a 65-year-old man with a diagnosis of buccal mucosa squamous cell carcinoma (T2N0M0). Left buccal mucosa squamous cell tumor resection and dermoplasty were performed, followed by alveolar ridge augmentation and buccal mucosal graft in the scar area. The carcinoma recurred, however, and left buccal mucosa carcinoma resection was performed, followed by reconstruction surgery using a free forearm flap. After a 12-week healing period, a molar support was constructed on the unaffected side and a protective prosthesis placed on the affected side. Training in ingestion and swallowing were given postoperatively. The patient in the second case was a 62-year-old woman with a diagnosis of buccal mucosa squamous cell carcinoma (T2N1M0). Right buccal mucosa carcinoma resection and supra-omohyoid neck dissection were performed, followed by reconstruction surgery using a free forearm flap. A molar support was constructed on the unaffected side and a protec tive prosthesis placed on the affected side at 5 months postoperatively. Training was given in ingestion and swallowing postoperatively. The prostheses prevented bite wounds to the flaps in the affected areas due to jaw movement during swallowing or speaking. The postoperative courses were uneventful, and the average masticatory score was 92.5 (85, 100), not affecting daily life. The prostheses were placed after reconstruction surgery using free flaps after buccal mucosa squamous cell carcinoma resection. Dysphasia recovered to the preoperative level by dysphasia and pronunciation training in both cases. The postoperative prognosis was favorable, with the prosthesis preventing damage to the flap.

1 January 2021 in The Bulletin of Tokyo Dental College
Verified
Journal Article
Closed access
PDF file
SNSyuntaro Nomoto
Syuntaro Nomoto
TMTomotoshi Masuda
Tomotoshi Masuda
TSToru Sato
Toru Sato
MYMariko Yumoto
Mariko Yumoto
GKGen Kuroishi
Gen Kuroishi
HSHideshi Sekine
Hideshi Sekine
A range of experimental designs have been used in destructive testing of composite resin CAD/CAM crowns. Various materials have been adopted for the abutment in such tests, including human or bovine dentin, stainless steel, PMMA, and composite resin, the selection of which is made in accordance with study objective or preference of the researcher. The purpose of this study was to determine how the material selected for the abutment material affected fracture load and maximum displacement. Destructive tests were conducted on composite resin crowns of the same design. Three types of material were used for the abutments together with 2 types of adhesive material. Images of each sample were acquired before destruction using a microfocus X-ray CT scanner to confirm the feasibility of a non-destructive test. The load required to fracture the composite CAD/CAM resin crowns depended on the abutment material used, with a decrease being observed in the order of composite resin, stainless steel, and PMMA. Maximum displacement decreased in the order of PMMA, composite resin, and stainless steel. Differences in the material used for setting (adhesive resin or polycarboxylate cement) showed no effect on fracture load. These results indicate that the load required to achieve destruction of resin CAD/CAM crowns varies according to the abutment material used.