Nora Sultani

Ms. Nora Sultani

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
NKNatalia Anna Kazimierczak
Natalia Anna Kazimierczak
NSNora Sultani
Nora Sultani
NCNatalia Chwarścianek
Natalia Chwarścianek
SKSzymon Krzykowski
Szymon Krzykowski
ZSZbigniew Serafin
Zbigniew Serafin
Wojciech KazimierczakWojciech Kazimierczak
Wojciech Kazimierczak
Background/Objectives: Artificial intelligence (AI) systems may enhance diagnostic accuracy in cone-beam computed tomography (CBCT) analysis. However, most validations focus on isolated tooth-level tasks rather than clinically meaningful full-mouth assessment outcomes. To evaluate the diagnostic accuracy of a commercial AI platform for detecting dental treatment features on CBCT images at both tooth and full-scan levels. Methods: In this retrospective single-center study, 147 CBCT scans (4704 tooth positions) were analyzed. Two experienced readers annotated treatment features (missing teeth, fillings, endodontic treatments, crowns, pontics, orthodontic appliances, implants), and consensus served as the reference. Anonymized datasets were processed by a cloud-based AI system (Diagnocat Inc., San Francisco, CA, USA). Diagnostic metrics—sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and F1-score—were calculated with 95% patient-clustered bootstrap confidence intervals. A “Perfect Agreement” criterion defined full-scan level success as an entirely error-free full-mouth report. Results: Tooth-level AI performance was excellent, with accuracy exceeding 99% for most categories. Sensitivity was highest for missing teeth (99.3%) and endodontic treatments (99.0%). Specificity and NPV exceeded 98.5% and 99.7%, respectively. Full-scan level Perfect Agreement was achieved in 82.3% (95% CI: 76.2–88.4%), with errors concentrated in teeth presenting multiple co-existing findings. Conclusions: The evaluated AI platform demonstrates near-perfect accuracy in detecting isolated dental features but moderate reliability in generating complete full-mouth reports. It functions best as an assistive diagnostic tool, not as an autonomous system.

15 May 2026 in Dentomaxillofacial Radiology
Verified
Journal Article
Open access
NSNora Sultani
Nora Sultani
NKNatalia Anna Kazimierczak
Natalia Anna Kazimierczak
ZSZbigniew Serafin
Zbigniew Serafin
Wojciech KazimierczakWojciech Kazimierczak
Wojciech Kazimierczak
Objectives: To assess the diagnostic accuracy of a commercial artificial intelligence system for automated tooth numbering on panoramic radiographs and cone-beam CT (CBCT) and to quantify case-level reliability. Methods: In this retrospective single-center diagnostic accuracy study, consecutive patients who underwent both panoramic radiography and CBCT in 2024 were included. The index test was automated tooth numbering generated by Diagnocat using the Fédération Dentaire Internationale numbering scheme. The reference standard was modality-specific consensus of 2 experienced, blinded readers. Tooth-position performance metrics with 95% confidence intervals were estimated using patient-level cluster bootstrap. Case-level reliability was defined as the proportion of examinations with completely error-free numbering across all evaluated tooth positions. Results: The study analyzed 171 paired panoramic radiographs and CBCT examinations, evaluating 4900 tooth positions per modality (9800 total). Tooth-position performance was identical and high across modalities (per-tooth accuracy 99.29% for both; overall position-based accuracy 98.73% [95% CI 97.97–99.38]). At the case level, 148/171 (86.5%) panoramic radiographs and 155/171 (90.6%) cone-beam computed tomography examinations were error-free. Conclusions: Despite high tooth-position metrics, approximately 1 in 10 to 1 in 7 examinations required at least one manual correction, demonstrating a gap between granular accuracy and case-level reliability. Advances in knowledge: Reporting case-level, error-free outputs alongside tooth-position metrics provides a more clinically meaningful estimate of reliability for automated tooth numbering and supports safer workflow implementation.

28 May 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
ALAnna Lackowska
Anna Lackowska
NKNatalia Anna Kazimierczak
Natalia Anna Kazimierczak
NCNatalia Chwarścianek
Natalia Chwarścianek
NSNora Sultani
Nora Sultani
ZSZbigniew Serafin
Zbigniew Serafin
Wojciech KazimierczakWojciech Kazimierczak
Wojciech Kazimierczak
Background/Objectives: The objective of our study was to compare the diagnostic performance of a popular, commercial dental artificial intelligence (AI) platform (Diagnocat, DGNCT LLC, Miami, FL, USA) for detecting maxillary sinus abnormalities on paired panoramic radiographs (OPG) and cone-beam computed tomography (CBCT) acquired in the same patients, and to examine whether lesion conspicuity predicts correct AI decisions. Methods: In this retrospective paired study, 166 patients contributed 332 maxillary sinuses with OPG and CBCT performed ≤30 days apart. The reference standard was consensus CBCT reading by two observers with third-reader arbitration. The index test was the AI’s sinus-level binary output (any abnormality). Accuracy, precision, recall, and F1 score were estimated with patient-clustered 95% bootstrap CIs; secondary analyses assessed category-specific performance and the effect of mucosal thickness and polyp/cyst volume. Results: Our evaluation showed that the platform’s performance depended on modality. On CBCT, the accuracy was 69.88% (64.76–74.70%), precision was 87.83% (81.58–93.33%), recall was 54.01% (46.74–61.17%), and F1 score was 66.89% (60.34–72.84%). On OPG, the accuracy was 50.6% (44.58–55.41%), precision was 67.80% (55.38–79.66%), recall was 21.39% (15.62–27.32%), and F1 score 32.52% (24.79–39.69%). On CBCT, higher mucosal thickness and larger polyp/cyst volume strongly predicted correct AI calls; no such effect was seen with OPG. Conclusions: In conclusion, the evaluated AI showed high precision but only moderate recall on CBCT and unreliable performance on OPG. Outputs must be interpreted by a professional; AI alerts on OPG should not guide management without CBCT confirmation.