A miniaturised dielectric barrier discharge at atmospheric pressure is used for the detection of metals dissolved in liquids by means of optical emission spectrometry. The plasma is formed inside a fused silica capillary with an inner diameter of 700 μm between the flowing liquid surface and a tungsten electrode with 400 μm diameter. In this case, the flowing liquid with 1 mol L−1nitric acid forms the other electrode of the plasma. A liquid flow rate of 20 μL min−1 is used and the pulsed high voltage with 3.2 kVpp and 87 kHz is dielectric coupled into the liquid over a copper coating on the outer capillary surface, where the dielectric barrier is formed by the wall of the capillary. Disequilibrium between the liquid flow rate and transfer rate into the plasma causes a pulsation of the discharge. This pulsation shows a positive effect on the long-term stability of the discharge, where the discharge can be sustained in the range of one hour and more. The stability of the discharge is influenced also by the nitric acid concentration and therefore the conductivity of the liquid. Calibration measurements are performed for several alkali, alkaline earth metals and silver. Detection limits are determined between 0.02 mg L−1 for potassium and 6.9 mg L−1 for barium. Together with the achieved stability and low flow rate the application as a monitoring device in flow systems or coupling with micro-separation devices seems possible.
1 July 2013 in Spectrochimica Acta Part B: Atomic Spectroscopy
Background: Aminopeptidase N (CD13) is present on tumor vasculature cells and some tumor cells. Truncated tissue factor (tTF) with a C-terminal NGR-peptide (tTF-NGR) binds to CD13 and causes tumor vascular thrombosis with infarction. Methods: We treated 17 patients with advanced cancer beyond standard therapies in a phase I study with tTF-NGR (1-h infusion, central venous access, 5 consecutive days, and rest periods of 2 weeks). The study allowed intraindividual dose escalations between cycles and established Maximum Tolerated Dose (MTD) and Dose-Limiting Toxicity (DLT) by verification cohorts. Results: MTD was 3 mg/m2 tTF-NGR/day × 5, q day 22. DLT was an isolated and reversible elevation of high sensitivity (hs) Troponin T hs without clinical sequelae. Three thromboembolic events (grade 2), tTF-NGR-related besides other relevant risk factors, were reversible upon anticoagulation. Imaging by contrast-enhanced ultrasound (CEUS) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) showed major tumor-specific reduction of blood flow in all measurable lesions as proof of principle for the mode of action of tTF-NGR. There were no responses as defined by Response Evaluation Criteria in Solid Tumors (RECIST), although some lesions showed intratumoral hemorrhage and necrosis after tTF-NGR application. Pharmacokinetic analysis showed a t1/2(terminal) of 8 to 9 h without accumulation in daily administrations. Conclusion: tTF-NGR is safely applicable with this regimen. Imaging showed selective reduction of tumor blood flow and intratumoral hemorrhage and necrosis.
1 December 2015 in Spectrochimica Acta Part B: Atomic Spectroscopy
Molecular beam mass spectrometry is a powerful diagnostic technique, which can be used for the measurement of absolute number densities of reactive species in non-equilibrium reactive plasmas. However, the calibration of absolute number densities is susceptible to systematic errors. Critical issues are the proper design of the sampling system and the correction of the background signal. Here we discuss the effect of reflections of particles from the molecular beam in an ionizer, formation of additional background particle density in the ionizer, and its effect on the density calibration of reactive particle densities. A Monte Carlo simulation of particle trajectories in the ionizer is used to estimate the detection probability of a beam particle after the collision with the ionizer wall. The simulation shows that as much as two-third of the signal can be due to scattered particles in the commercially available mass spectrometers. This effect leads to systematic underestimation of densities of reactive particles, which are reactive at the surface and, therefore, do not have any background density. A simple change in the ionizer geometry is suggested, which can significantly reduce this problem.