Noëlle Uilenburg

Mrs. Noëlle Uilenburg


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2012 in International Journal of Audiology
Verified
Journal Article
Closed access
CPC. P. B. van der Ploeg
C. P. B. van der Ploeg
NUNoëlle Uilenburg
Noëlle Uilenburg
MBM. A. Kauffman-De Boer
M. A. Kauffman-De Boer
AOA. M. Oudesluys-Murphy
A. M. Oudesluys-Murphy
PVP. H. Verkerk
P. H. Verkerk
Objective: The aim of this study is to investigate whether the quality of the Dutch, community based, universal newborn hearing screening programme is consistent over time. Design: Universal newborn hearing screening data from three cohorts are compared on a number of quality targets concerning the outcome of the screening and the process of the screening in a three stage, community based, hearing screening programme. Study sample: A total of 552 820 children entered the study (189 794 in 2002–2006; 181 574 in 2008, and 181 452 in 2009). Results: Participation in the programme is high from implementation onwards and increases over time for all screen stages to percentages above 99%. Refer rates are within quality targets and they are consistent over time. The screening is completed within 42 days of birth for 91.5% of the children in the last cohort. Of all children screened, 0.29% to 0.30% are referred to a speech and hearing centre. Participation in diagnostic testing is 93.3% to 95.2%. Of all referred children 77% to 85% receive a diagnosis within 122 days of birth. Conclusions: A good quality neonatal hearing screening programme in youth health care has been established in the Netherlands. However, both participation in diagnostic testing after a positive screen result and the timing of the diagnostic testing can still be improved.

1 January 2009 in International Journal of Audiology
Verified
Journal Article
Closed access
NUNoëlle Uilenburg
Noëlle Uilenburg
MBMinca Kauffman-De Boer
Minca Kauffman-De Boer
KPKitty van der Ploeg
Kitty van der Ploeg
AOAnne Marie Oudesluys-Murphy
Anne Marie Oudesluys-Murphy
PVPaul Verkerk
Paul Verkerk
The objective of this study was to investigate whether universal neonatal hearing screening could be integrated in the youth health care program. The screening was performed by nurses of the well baby clinics. A three stage transient evoked otoacoustic emission screening was performed in three different screening settings in order to study the most effective set up regarding participation, refer rates, and costs. In one setting parents visited the well baby clinic, and in two settings babies were screened at home (either in combination with the screening for metabolic diseases or during an intake visit). Screening was performed on 3114 healthy newborns. The setting where universal neonatal hearing screening is integrated with the screening for metabolic diseases, proved to be most efficient and effective. The participation rate of 88.9% was highest in this setting and the overall refer rate (1.4%) was the lowest. The implementation of universal neonatal hearing screening by the well baby clinic nurses was judged to be possible. The results of this study formed the basis for nationwide implementation.

16 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RZRosanne Van der Zee
Rosanne Van der Zee
NUNoëlle Uilenburg
Noëlle Uilenburg
KPKitty Van Der Ploeg
Kitty Van Der Ploeg
EDEvelien Dirks
Evelien Dirks
Background: Few studies report prevalence rates of hearing loss in newborns for nationwide populations. The Dutch well-baby newborn hearing screening covers almost all eligible children and has high participation rates for follow-up screening rounds and diagnosis. This allows calculating reliable prevalence rates of permanent neonatal hearing loss specified by severity. Methods: Results from the well-baby newborn hearing screening program and diagnostic follow-up of referred children from 2015 to 2019 were included in calculating prevalence rates. Hearing loss was classified according to the degree of severity. Results: A total of 99.7% of 833,318 children eligible for screening were included. A total of 0.3% were referred for audiological diagnostics. Permanent bilateral hearing loss of ≥40 dB was diagnosed in 23.7% of them and unilateral hearing loss in 14.4%. A prevalence rate of 1.23 per 1000 children was found, 0.46 for unilateral hearing loss and 0.76 for bilateral hearing loss. Moderate hearing loss is most common in children with bilateral hearing loss (0.47), followed by profound (0.21) and severe (0.06) hearing loss. In children with unilateral hearing loss, prevalence rates are the highest for profound hearing loss (0.21), followed by moderate (0.16) and severe (0.09) hearing loss. A total of 87.5% of the children were diagnosed within the age of 3 months. Conclusions: Because of the high quality of the Dutch well-baby hearing screening program, reported results approximate true prevalence rates of permanent hearing loss by severity.

22 January 2018 in Journal of Speech, Language, and Hearing Research
Verified
Journal Article
Closed access
PDF file
NUNoëlle Uilenburg
Noëlle Uilenburg
KWKarin Wiefferink
Karin Wiefferink
PVPaul Verkerk
Paul Verkerk
MDMargot van Denderen
Margot van Denderen
CSCarla van Schie
Carla van Schie
AOAnne-Marie Oudesluys-Murphy
Anne-Marie Oudesluys-Murphy
Purpose: A screening tool called the VTO Language Screening Instrument (VTO-LSI) was developed to enable more uniform and earlier detection of language impairment. This report, consisting of 2 retrospective studies, focuses on the effects of using the VTO-LSI compared to regular detection procedures. Method: Study 1 retrospectively compared VTO-LSI with regular detection procedures. Outcome measure was the detection rate of language impairment among 24-month-old children. Data were retrieved from medical records of children attending a youth health care center. Study 2 retrospectively compared the effects of VTO-LSI and regular detection procedures on the age at referral for diagnostic investigations and the influence of sex. Data were retrieved from medical records from the speech and hearing center and analyzed with multivariate analysis of variance. Results: With the VTO-LSI, significantly more cases with language impairment were identified compared with the regular detection procedure (2.4% vs. 0.4%). In regions where the VTO-LSI was used, girls were almost 2 years younger, and boys were 1 year younger when referred to diagnostic investigations than in regions with regular detection procedures. Conclusion: The VTO-LSI was more effective than regular detection procedures.

Verified
Journal Article
Open access
PDF file
NUNoëlle Uilenburg
Noëlle Uilenburg
KPKitty Van Der Ploeg
Kitty Van Der Ploeg
RZRosanne Van der Zee
Rosanne Van der Zee
AMAnneke Meuwese-Jongejeugd
Anneke Meuwese-Jongejeugd
GZGijsbert Van Zanten
Gijsbert Van Zanten
In the Netherlands, Youth Health Care services (YHC) have been carrying out neonatal hearing screening (NHS) in newborns since 2006. The aim of the NHS is to identify children with permanent hearing loss, so that intervention can be started before the age of 4 months. Early detection of hearing loss is important, as children who start intervention early have been shown to develop better. This article describes the structure and performance of the NHS carried out by the YHC, the quality of the program, and the timeliness of the start of intervention. Since its implementation, the NHS has been audited annually in order to monitor the program’s quality. Monitoring reports and data from the Dutch Foundation for the Deaf and Hard of Hearing Child were used in this study. For many years, results have shown the NHS to be a stable screening program of high quality. The participation rate is high, refer percentage low, and the timeliness of the program is continually improving. Although the timeliness of post screening diagnostics and intervention need most improvement as they do not always meet the target times, this has improved over recent years.

Verified
Journal Article
Open access
PDF file
LVLisanne Vonk
Lisanne Vonk
PDPaula Van Dommelen
Paula Van Dommelen
IEIris Eekhout
Iris Eekhout
NUNoëlle Uilenburg
Noëlle Uilenburg
PVPaul H. Verkerk
Paul H. Verkerk
KPKitty Van Der Ploeg
Kitty Van Der Ploeg
In The Netherlands, preventive child healthcare (PCHC) has been carrying out neonatal hearing screening in well-babies since 2006. The aim of this study was to examine the relationship between the age of newborns and the false positive referral rate of the first hearing screening using a transient evoked otoacoustic emission (OAE) test, to identify the most efficient timing for OAE screening. Additionally, we investigated the relationship between the type of OAE screening device (Echoscreen (ES)I/II versus ESIII) and the referral rate during the first screening. We used data from the Dutch universal well-baby neonatal hearing screening programme by PCHC between 2013 and 2023. Multilevel logistic regression analyses were performed to estimate the probability of a referral in 2023 for newborns screened in 2022 and 2023. We included a total of 1,650,506 newborns for 2013–2022 and 323,194 newborns for 2022–2023. The lowest false positive referral rates were found between days five and thirteen, ranging from 3.3 to 3.9%. ESIII significantly increased the probability of a referral compared to ESI/II (odds ratio = 1.84, 95% confidence interval = 1.65–2.06). In conclusion, the timing of neonatal hearing screening significantly impacts the false positive referral rate. Furthermore, the likelihood of a referral is significantly higher when using the ESIII compared to the ESI/II.