Titanium nitride (TiNx) was deposited by reactive sputtering using a titanium target in a nitrogen ambient. Nitrogen flow rate during deposition was varied in order to investigate its effect on film resistivity. Conductivity is found to improve with increasing nitrogen content. Films were then annealed, varying the time and temperature of the anneal. Resistivity was found to decrease with longer annealing time and higher temperature during post deposition annealing. TiNx films showed good thermal and electrical stability upon annealing and did not show any silicon diffusion. It was found that film orientation can influence the resistivity, with [111] oriented films more resistive than [200] oriented films. Moreover, re-crystallization effects brought on by post deposition annealing cause the resistivity to decrease. Films deposited above 20% nitrogen flow rates during deposition were all stoichiometric TiN. However, TiNx deposited at very high nitrogen flow rate was found to be electrically, thermally and morphologically more stable than the ones deposited at low nitrogen flow rates
26 December 2007 in IEEE Transactions on Electron Devices
This paper discusses self-heating (SHE) effects in silicon-on-insulator (SOI) CMOS technology and applies device simulation to analyze the impact of thermal effects on the operation of nanoscale SOI n-MOSFETs. A 2-D drift-diffusion electrothermal simulation, using an electron transport model calibrated against Monte Carlo simulations at various temperatures, is employed in the analysis. We report the effects of device-structure parameters, such as SOI layer thickness, buried-oxide (BOX) thickness, source/drain (S/D) extension length, and thickness of the elevated S/D region, on the SHE of nanoscale MOSFETs. The SHE effects become significant due to the adoption of thin silicon layers and to the low thermal conductivity of the BOX, leading to the rise of large temperature under nominal operation conditions for high-performance digital circuits. The ac performance of SOI MOSFETs is influenced as well, and in particular, a severe degradation of the cutoff frequency of very short MOSFETs is predicted by numerical electrothermal device simulations. Although the effects of SHE on device performance are found to be somewhat modest and might be mitigated through device design, they may result in a degradation of the long-term reliability.
Micromotion between the brain and implanted electrodes is a major contributor to the failure of invasive brain–machine interfaces. Movements of the electrode tip cause recording instabilities while spike amplitudes decline over the weeks/months post-implantation due to glial cell activation caused by sustained mechanical trauma. We have designed a sinusoidal probe in order to reduce movement of the recording tip relative to the surrounding neural tissue. The probe was microfabricated from flexible materials and incorporated a sinusoidal shaft to minimize tethering forces and a 3D spheroid tip to anchor the recording site within the brain. Compared to standard microwire electrodes, the signal-to-noise ratio and local field potential power of sinusoidal probe recordings from rabbits was more stable across recording periods up to 678 days. Histological quantification of microglia and astrocytes showed reduced neuronal tissue damage especially for the tip region between 6 and 24 months post-implantation. We suggest that the micromotion-reducing measures incorporated into our design, at least partially, decreased the magnitude of gliosis, resulting in enhanced longevity of recording.
24 December 2002 in Semiconductor Science and Technology
Surface channel strained-silicon MOSFETs on relaxed Si/sub 1-x/Ge/sub x/ virtual substrates (VSs) have been established as an attractive avenue for extending Si CMOS performance as dictated by Moore's law. The performance of a surface channel Si n-MOSFET is significantly influenced by strained Si/SiO/sub 2/ interface quality. The effects of Ge content (20, 25, and 30%) in the VS and strained-Si thickness (6, 5.5, 4.7, and 3.7 nm) on the strained Si/SiO/sub 2/ interface have been investigated. The interface trap density was found to be proportional to the Ge content in the VS. Fixed oxide charge density reduces to a lower limit at higher strained-Si thickness for any Ge content in the VS, and the value increases as the strained-Si thickness is reduced. There is a high concentration of interface trap charge and fixed oxide charge present for devices with a strained-Si channel thickness below 4.7 nm. To investigate the effect of strained Si/SiO/sub 2/ interface quality on MOSFET devices fabricated using a high-temperature CMOS process, the performance of surface channel n-MOSFETs has been correlated with channel thickness. It is noted that the drain-current rapidly decreases at low gate voltages for channel thicknesses less than 4.7 nm. The performance of both MOS capacitors and MOSFETs degraded below a strained-Si thickness of 4.7 nm irrespective of the Ge content in the VS even up to 30%. TCAD simulations have been carried out to analyze the effect of strained Si/SiO/sub 2/ interface on electrical characteristics. Performance degradation in thin strained-Si channels is primarily attributed to gate oxide quality. The out-diffused Ge accumulates at the strained Si/SiO/sub 2/ interface, introducing a significant amount of interface traps and fixed oxide charges during thermal oxidation. Interface trap density and fixed oxide charge density significantly increased when the Ge concentration at the surface becomes more than 6%. This paper suggests that a minimum strained-Si layer thickness of /spl sim/ 5.0 nm is required to achieve a good strained Si/SiO/sub 2/ interface quality for surface channel strained-Si n-MOSFETs, fabricated using a high thermal budget CMOS process.
Micromotion between the brain and implanted electrodes is a major contributor to the failure of invasive microelectrodes. Movements of the electrode tip cause recording instabilities while spike amplitudes decline over the weeks/months post-implantation due to glial cell activation caused by sustained mechanical trauma. We compared the glial response over a 26–96 week period following implantation in the rabbit cortex of microwires and a novel flexible electrode. Horizontal sections were used to obtain a depth profile of the radial distribution of microglia, astrocytes and neurofilament. We found that the flexible electrode was associated with decreased gliosis compared to the microwires over these long indwelling periods. This was in part due to a decrease in overall microgliosis and enhanced neuronal density around the flexible probe, especially at longer periods of implantation.