Shicai Fan

Dr. Shicai Fan


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2017 in Materials
Verified
Journal Article
Open access
PDF file
Di WangDi Wang
Di Wang
YWYimeng Wang
Yimeng Wang
SWShibiao Wu
Shibiao Wu
HLHui Lin
Hui Lin
Di WangDi Wang
Di Wang
CSChanghui Song
Changhui Song
In pelvic fracture operations, bone plate shaping is challenging and the operation time is long. To address this issue, a customized bone plate was designed and produced using selective laser melting (SLM) technology. The key steps of this study included designing the customized bone plate, metal 3D printing, vacuum heat treatment, surface post-processing, operation rehearsal, and clinical application and evaluation. The joint surface of the bone plate was placed upwards with respect to the build platform to keep it away from the support and to improve the quality of the joint surface. Heat conduction was enhanced by adding a cone-type support beneath the bone plate to prevent low-quality fabrication due to poor heat conductivity of the Ti-6Al-4V powder. The residual stress was eliminated by exposing the SLM-fabricated titanium-alloy bone plate to a vacuum heat treatment. Results indicated that the bone plate has a hardness of HV1 360–HV1 390, an ultimate tensile strength of 1000–1100 MPa, yield strength of 900–950 MPa, and an elongation of 8%–10%. Pre-operative experiments and operation rehearsal were performed using the customized bone plate and the ABC-made pelvic model. Finally, the customized bone plate was clinically applied. The intraoperative C-arm and postoperative X-ray imaging results indicated that the customized bone plate matched well to the damaged pelvis. The customized bone plate fixed the broken bone and guides pelvis restoration while reducing operation time to about two hours. The customized bone plate eliminated the need for preoperative titanium plate pre-bending, thereby greatly reducing surgical wounds and operation time.

10 July 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
CWCanbin Wang
Canbin Wang
YCYuhui Chen
Yuhui Chen
LWLiping Wang
Liping Wang
DWDi Wang
Di Wang
CGCheng Gu
Cheng Gu
JDJianghui Dong
Jianghui Dong
Background: Complicated acetabular fractures comprise the most challenging field for orthopedists. The purpose of this study was to develop three-dimensional printed patient-specific (3DPPS) Ti-6Al-4 V plates to treat complicated acetabular fractures involving quadrilateral plate (QLP) disruption and to evaluate their efficacy.Methods: Fifty patients with acetabular fractures involving QLP disruption were selected between January 2016 and June 2017. Patients were divided into a control group (Group A, 35 patients) and an experimental group (Group B, 15 patients), and were treated by the conventional method of shaping reconstruction plates or with 3DPPS Ti-6AL-4 V plates, respectively. The efficacy of Ti-6AL-4 V plates was evaluated by blood loss, operative time, reduction quality, postoperative residual displacement, and complications.Results: The operative time and blood loss in Group B were reduced compared to Group A, and the difference was statistically significant (P < 0.05). There was no significant difference in reduction quality between the two groups (P > 0.05). Reduction quality in Group B was anatomic in 10 (66.7%), satisfactory in four (26.7%), and poor in one (6.7%). In Group A, they were anatomic in 18 (51.4%), satisfactory in 13 (37.1%), and poor in four (11.4%). Residual displacement in Group B was less than that in Group A, and the difference was statistically significant (P < 0.05). In Group B, one case exhibited loosening of the pubic screw postoperatively. In Group A, there was one case of wound infection, one of deep vein thrombosis (DVT) in the ipsilateral lower limb, one case of traumatic arthritis and two obturator nerve injuries.Conclusions: The 3DPPS Ti-6AL-4 V plate is a feasible, accurate and effective implant for acetabular fracture treatment.

22 February 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
XLXuezhi Lin
Xuezhi Lin
XXXingling Xiao
Xingling Xiao
YWYimeng Wang
Yimeng Wang
CGCheng Gu
Cheng Gu
CWCanbin Wang
Canbin Wang
SFShicai Fan
Shicai Fan
Treatment of acetabular fractures is challenging, not only because of its complicated anatomy but also because of the lack of fitting plates. Personalized titanium alloy plates can be fabricated by selective laser melting (SLM) but the biocompatibility of these three-dimensional printing (3D-printed) plates remains unknown. Plates were manufactured by SLM and their cytocompatibility was assessed by observing the metabolism of L929 fibroblasts incubated with culture medium extracts using a CCK-8 assay and their morphology by light microscopy. Allergenicity was tested using a guinea pig maximization test. In addition, acute systemic toxicity of the 3D-printed plates was determined by injecting extracts from the implants into the tail veins of mice. Finally, the histocompatibility of the plates was investigated by implanting them into the dorsal muscles of rabbits. The in vitro results suggested that cytocompatibility of the 3D-printed plates was similar to that of conventional plates. The in vivo data also demonstrated histocompatibility that was comparable between the two manufacturing techniques. In conclusion, both in vivo and in vitro experiments suggested favorable biocompatibility of 3D-printed titanium alloy plates, indicating that it is a promising option for treatment of acetabular fractures.

4 January 2019 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
JCJiahui Chen
Jiahui Chen
HLHan Liu
Han Liu
CWCanbin Wang
Canbin Wang
XLXuezhi Lin
Xuezhi Lin
Cheng GuCheng Gu
Cheng Gu
SFShicai Fan
Shicai Fan
This study aims to examine the clinical efficacy and surgical techniques of the lateral-rectus approach for treatment of acetabular factures in elderly patients. After appropriate exclusion, 65 elderly patients with an acetabular fracture who was treated through the lateral-rectus approach from January 2011 and October 2016 were selected retrospectively. By analyzing the medical records retrospectively, the patients’ characteristics, fracture type, mechanism of injury, comorbid conditions, ASA class, operative time, intra-operative blood loss, and post-operative complications were assessed. Clinical examination radiographs have been taken, align with the Matta evaluation system. Functional outcomes were evaluated using surveys including SF-36, Harris hip score, and modified Merle D’Aubigne-Postel. All 65 patients had undergone the single lateral-rectus approach successfully. Surgery duration was 101.23 min on average (45–210), and intra-operative bleeding was 798.46 ml on average (250–1800). According to the Matta radiological evaluation, the quality of reduction evaluated 1 week after surgery was rated as “anatomical” in 41 (63.1%) cases, “imperfect” in 12 (18.5%) cases, and “poor” in 12 (18.5%) cases. The modified Merle D’Aubigne-Postel score performed 18 months after surgery was categorized as excellent in 40 (61.5%) cases, good in 10 (15.4%) cases, and fair in 15 (23.1%) cases. The mean Harris Hip score was similar as present researches, being 87.18. The mean SF-36 score was 69.12 which was considered as normal for the group age 60 and older. Several complications were found, including screw loosening in 10 cases, fat liquefaction of incision in 2 cases, deep vein thrombosis in 2 cases, and temporary weakness of hip adductors in 5 cases. None of the patients had heterotopic ossification. The lateral-rectus approach is a valuable alternative to the ilioinguinal and modified Stoppa approach, being the treatment of acetabular fractures in elderly patients.

3 August 2024 in International Journal of Biological Macromolecules
Verified
Journal Article
Closed access
WZWentong Zhao
Wentong Zhao
RLRuanbing Li
Ruanbing Li
ZXZhipeng Xiao
Zhipeng Xiao
FYFang Yang
Fang Yang
SCSheqiang Chen
Sheqiang Chen
SFShicai Fan
Shicai Fan

30 June 2022 in Orthopaedic Surgery
Verified
Journal Article
Open access
XZXiaorui Zhan
Xiaorui Zhan
KXKangshuai Xu
Kangshuai Xu
QZQiubao Zheng
Qiubao Zheng
SCSheqiang Chen
Sheqiang Chen
JLJiacheng Li
Jiacheng Li
SFShicai Fan
Shicai Fan
Objective: To examine the surgical techniques and preliminary outcomes of the lateral rectus approach (LRA) for treating vertical shear (VS) pelvic fracture associated with lumbosacral plexus (LSP) injury.Methods: This study was a retrospective trial. From August 2010 to October 2017, 29 patients withVSpelvic fractures involving LSP injury who were treated with the LRA were included in this study. The patients were 18–61 years old, with a mean age of 36.2 years. All patients underwent neurolysis, open reduction, and internal fixation (ORIF) through the LRA. The fracture reduction was evaluated using the Matta criteria, and the neural recovery was evaluated by muscle strength grading proposed by the British Medical Research Council (BMRC).Results: All 29 patients underwent the surgery successfully. The mean operating time was 155.2 ± 32.1 min (range: 105–220 min). The mean operative blood loss was 1021.4 ± 363.4 mL (range: 400–2000 mL). All patients were followed‐up for at least 24 months (mean, 32.8 ± 13.5 months; range: 24–96 months). According to the Matta criteria, there were 17 excellent cases, nine good cases, and three fair cases in 29 patients. The ratio of excellent‐to‐good cases was 89.66%. According to the criteria of the Nerve Injuries Committee of the British Medical Research Council (BMRC), the recovery of nerve and muscle strength achieved to M5 (full recovery of neurological symptoms) was 14 cases, M4 (fine recovery of neurological symptoms), seven cases; M1, M2, and M3 (partial recovery of neurological symptoms), five cases, and M0 (no recovery of neurological symptoms), three cases.Conclusions: LRA is a safe and feasible surgical approach for treatingVSpelvic fractures with LSP injury, which can be used to perform nerve exploration and release from the front, reduce the fracture, and fix it with the anterior iliac plates and/or sacroiliac screws.