Denise Bos

Dr. Denise Bos

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2023 in Deutsches Ärzteblatt international
Verified
Journal Article
Closed access
DBDenise Bos
Denise Bos
NGNika Guberina
Nika Guberina
SZSebastian Zensen
Sebastian Zensen
MOMarcel Opitz
Marcel Opitz
MFMichael Forsting
Michael Forsting
AWAxel Wetter
Axel Wetter
Computed tomography (CT) studies are requested by specialists from most medical disciplines and play a vital role in the diagnosis and treatment of patients. It follows that physicians of all specialties should possess basic knowledge of computed tomography, its proper use, and the radiation exposure associated with it. This review is based on publications retrieved by a selective search of the literature. Approximately 12 million CT studies are carried out in Germany each year, and the trend is rising. Approximately 9% of all diagnostic studies involving ionizing radiation are CT studies. On average, more than 60% of the collective effective dose due to medical radiation exposure is attributable to CT. There are two types of radiation effects caused by ionizing radiation: stochastic and deterministic. The additional, individual relative lifetime cancer mortality risk due to ionizing radiation with whole-body exposure at a low single dose is estimated at 5% per sievert. Radiation exposure from CT studies of the head and trunk, e.g. of a patient with polytrauma, corresponds to an additional lifetime cancer mortality risk of approximately 0.1% at an effective dose of approximately 20 millisievert. The radiation exposure due to CT, and the risks to which patients are subjected by it, have become more important with greater use of CT. Technical advances, targeted dose monitoring, and analyses of dose data can help identify areas where improvement is necessary, in furtherance of the overriding goal of lowering patients’ radiation exposure while preserving adequate image quality.

13 October 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
DBDenise Bos
Denise Bos
SYSophronia Yu
Sophronia Yu
JLJason Luong
Jason Luong
PCPhilip Chu
Philip Chu
YWYifei Wang
Yifei Wang
RSRebecca Smith-Bindman
Rebecca Smith-Bindman
Ob jectives: The European Society of Radiology identified 10 common indications for computed tomography (CT) as part of the European Study on Clinical Diagnostic Reference Levels (DRLs, EUCLID), to help standardize radiation doses. The objective of this study is to generate DRLs and median doses for these indications using data from the UCSF CT International Dose Registry. Methods: Standardized data on 3.7 million CTs in adults were collected between 2016 and 2019 from 161 institutions across seven countries (United States of America (US), Switzerland, Netherlands, Germany, UK, Israel, Japan). DRLs (75th percentile) and median doses for volumetric CT-dose index (CTDIvol) and dose-length product (DLP) were assessed for each EUCLID category (chronic sinusitis, stroke, cervical spine trauma, coronary calcium scoring, lung cancer, pulmonary embolism, coronary CT angiography, hepatocellular carcinoma (HCC), colic/abdominal pain, appendicitis), and US radiation doses were compared with European. Results: The number of CT scans within EUCLID categories ranged from 8,933 (HCC) to over 1.2 million (stroke). There was greater variation in dose between categories than within categories (p < .001), and doses were significantly different between categories within anatomic areas. DRLs and median doses were assessed for all categories. DRLs were higher in the US for 9 of the 10 indications (except chronic sinusitis) than in Europe but with a significantly higher sample size in the US. Conclusions: DRLs for CTDIvol and DLP for EUCLID clinical indications from diverse organizations were established and can contribute to dose optimization. These values were usually significantly higher in the US than in Europe. Key Points: • Registry data were used to create benchmarks for 10 common indications for CT identified by the European Society of Radiology. • Observed US radiation doses were higher than European for 9 of 10 indications (except chronic sinusitis). • The presented diagnostic reference levels and median doses highlight potentially unnecessary variation in radiation dose.

8 September 2020 in Neuroradiology
Verified
Journal Article
Open access
PDF file
SZSebastian Zensen
Sebastian Zensen
NGNika Guberina
Nika Guberina
MOMarcel Opitz
Marcel Opitz
MKMartin Köhrmann
Martin Köhrmann
CDCornelius Deuschl
Cornelius Deuschl
DBDenise Bos
Denise Bos
Purpose: To assess suspected acute stroke, the computed tomography (CT) protocol contains a non-contrast CT (NCCT), a CT angiography (CTA), and a CT perfusion (CTP). Due to assumably high radiation doses of the complete protocol, the aim of this study is to examine radiation exposure and to establish diagnostic reference levels (DRLs). Methods: In this retrospective study, dose data of 921 patients with initial CT imaging for suspected acute stroke and dose monitoring with a DICOM header–based tracking and monitoring software were analyzed. Between June 2017 and January 2020, 1655 CT scans were included, which were performed on three different modern multi-slice CT scanners, including 921 NCCT, 465 CTA, and 269 CTP scans. Radiation exposure was reported for CT dose index (CTDIvol) and dose-length product (DLP). DRLs were set at the 75th percentile of dose distribution. Results: DRLs were assessed for each step (CTDIvol/DLP): NCCT 33.9 mGy/527.8 mGy cm and CTA 13.7 mGy/478.3 mGy cm. Radiation exposure of CTP was invariable and depended on CT device and its protocol settings with CTDIvol 124.9–258.2 mGy and DLP 1852.6–3044.3 mGy cm. Conclusion: Performing complementary CT techniques such as CTA and CTP for the assessment of acute stroke increases total radiation exposure. Hence, the revised DRLs for the complete protocol are required, where our local DRLs may help as benchmarks.

5 April 2022 in Pediatric Radiology
Verified
Journal Article
Open access
PDF file
DBDenise Bos
Denise Bos
SZSebastian Zensen
Sebastian Zensen
MOMarcel K. Opitz
Marcel K. Opitz
JHJohannes Haubold
Johannes Haubold
KNKai Nassenstein
Kai Nassenstein
NGNika Guberina
Nika Guberina
Background: Radiation exposures from computed tomography (CT) in children are inadequately studied. Diagnostic reference levels (DRLs) can help optimise radiation doses.Objective: To determine local DRLs for paediatric chest CT performed mainly on modern dual-source, multi-slice CT scanners as a function of patient size.Materials and methods: Five hundred thirty-eight chest CT scans in 345 children under 15 years (y) of age (median age: 8 y, interquartile range [IQR]: 4–13 y) performed on four different CT scanners (38% on third-generation and 43% on second-generation dual-source CT) between November 2013 and December 2020 were retrospectively analysed. Examinations were grouped by water-equivalent diameter as a measure of patient size. DRLs for volume CT dose index (CTDIvol) and dose-length product (DLP) were determined for six different patient sizes and compared to national and European DRLs.Results: The DRLs for CTDIvoland DLP are determined for each patient size group as a function of water-equivalent diameter as follows: (I) < 13 cm (n = 22; median: age 7 months): 0.4 mGy, 7 mGy·cm; (II) 13 cm to less than 17 cm (n = 151; median: age 3 y): 1.2 mGy, 25 mGy·cm; (III) 17 cm to less than 21 cm (n = 211; median: age 8 y): 1.7 mGy, 44 mGy·cm; (IV) 21 cm to less than 25 cm (n = 97; median: age 14 y): 3.0 mGy, 88 mGy·cm; (V) 25 cm to less than 29 cm (n = 42; median: age 14 y): 4.5 mGy, 135 mGy·cm; (VI) ≥ 29 cm (n = 15; median: age 14 y): 8.0 mGy, 241 mGy·cm. Compared with corresponding age and weight groups, our size-based DRLs for DLP are 54% to 71% lower than national and 23% to 85% lower than European DRLs.Conclusion: We developed DRLs for paediatric chest CT as a function of patient size with substantially lower values than national and European DRLs. Precise knowledge of size-based DRLs may assist other institutions in further dose optimisation in children.

14 June 2025 in European Radiology
Verified
Journal Article
Open access
PDF file
DBDenise Bos
Denise Bos
YWYifei Wang
Yifei Wang
CSCarly Stewart
Carly Stewart
PCPhilip W. Chu
Philip W. Chu
JLJason Luong
Jason Luong
RSRebecca Smith-Bindman
Rebecca Smith-Bindman
Objectives: Computed tomography (CT) radiation doses vary depending on medical indications, protocols, and local practice. Our aim is to establish diagnostic reference levels (DRLs) for CT categories based on clinical indications in pediatric patients. Materials and methods: We analyzed CT data from an international dose registry retrospectively, including scans performed in children under 18 years at 143 facilities between January 2016 and January 2021. DRLs were calculated for volumetric CT dose index (CTDI vol ), dose-length product (DLP), and size-specific dose estimate (SSDE) across 14 CT categories, which reflect both the anatomic areas and radiation dose levels (low, routine, high dose) required by imaging indications within the anatomic areas. We compared the routine dose categories for head, chest, and abdomen/pelvis scans between facilities in the United States (U.S.) and Europe. Results: A total of 95,047 CT scans (mean age, 10.4 ± 5.6 years, 54% male), including 41 different indications, were included. DRLs increased with increasing age group ( p < 0.05 for trend). For the head and the abdomen/pelvis body regions, there was greater variation between the CT categories than between the indications within the categories, suggesting these categories are valid. For example, in 10- to 15-year-old children, the DRLs for the DLP increased from 362 mGy·cm for head low dose to 2058 mGy·cm for head high dose. The U.S. DRLs were similar to the European for head categories, but were around twice as high for routine dose chest, and abdomen/pelvis. Conclusions: We have established DRLs for indication-based CT category age groups to help standardize practice. Key Points: Question CT categories are needed to reflect body regions and clinical indications with similar radiation dose requirements in pediatric patients . Findings Doses varied more between CT categories than within. DRLs for chest and abdomen/pelvis were about twice as high in the U.S. as in Europe . Clinical relevance DRLs as a function of patient age were developed for 14 broad anatomy- and indication-based CT categories in children using registry data . Graphical

23 May 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DBDenise Bos
Denise Bos
ADAydin Demircioğlu
Aydin Demircioğlu
JNJulia Neuhoff
Julia Neuhoff
JHJohannes Haubold
Johannes Haubold
SZSebastian Zensen
Sebastian Zensen
KNKai Nassenstein
Kai Nassenstein
In this retrospective study, we aimed to assess the objective and subjective image quality of different reconstruction techniques and a deep learning-based software on non-contrast head computed tomography (CT) images. In total, 152 adult head CT scans (77 female, 75 male; mean age 69.4 ± 18.3 years) obtained from three different CT scanners using different protocols between March and April 2021 were included. CT images were reconstructed using filtered-back projection (FBP), iterative reconstruction (IR), and post-processed using a deep learning-based algorithm (PS). Post-processing significantly reduced noise in FBP-reconstructed images (up to 15.4% reduction) depending on the protocol, leading to improvements in signal-to-noise ratio of up to 19.7%. However, when deep learning-based post-processing was applied to FBP images compared to IR alone, the differences were inconsistent and partly non-significant, which appeared to be protocol or site specific. Subjective assessments showed no significant overall improvement in image quality for all reconstructions and post-processing. Inter-rater reliability was low and preferences varied. Deep learning-based denoising software improved objective image quality compared to FBP in routine head CT. A significant difference compared to IR was observed for only one protocol. Subjective assessments did not indicate a significant clinical impact in terms of improved subjective image quality, likely due to the low noise levels in full-dose images.