Airborne acoustic surveillance would enable and ease several applications, including security surveillance, urban and industrial noise monitoring, rescue missions, and wildlife monitoring. Airborne surveillance with an acoustic camera mounted on an airship would provide the deployment flexibility and utility required by these applications. Nevertheless, and problematically for these applications, there is not a single acoustic camera mounted on an airship yet. We make significant advances towards solving this problem by designing and constructing an acoustic camera for direct mounting on the hull of a UAV airship. The camera consists of 64 microphones, a central processing unit, and software for data acquisition and processing dedicatedly developed for far-field low-level acoustic signal detection. We demonstrate a large-aperture mock-up camera operation on the ground, although all preparations have been made to integrate the camera onto an airship. The camera has an aperture of 2 m and has been designed for surveillance from a height up to 300 m, with a spatial resolution of 12 m.
Svaki infrastrukturni sistem ima svoje specifičnosti, koji se, između ostalog, odnose i na zahteve i realizaciju telekomunikacionog sistema. Jedan od uređaja sa karakterističnim zahtevima je pružni telefon u okviru železničke pružne telefonske mreže. Uslovljeno modernizacijom železničkog sistema, ali i zahtevima za kompatibilnošću sa postojećom infrastrukturom, razvijen je analogni univerzalni pružni telefon. U ovom radu je predstavljen ovaj uređaj, kroz prikaz karakterističnih hardverskih i softverskih komponenti, kao i princip funkcionisanja.
Corona audible noise from high-voltage overhead transmission lines is one of the problems faced by transmission network operators around the world. This problem has become a greater concern and is being globally instigated through research of the corona physical phenomenon, the development of empirical formulas, mathematical modeling, and software simulations. A part of the research refers to the corona audible noise measurements, whereas the obtained results represent the most relevant data that are included in the corrections of empirical formulas and mathematical models. This paper presents the adopted measurement methodology, based on several relevant standards, as well as data from extensive literature (research, scientific papers, reports). The methodology includes the selection of the measurement time interval, measurement location, measurement equipment, microphone position, and background noise cancellation. The measurement methodology is presented through an example measurement description and obtained and processed results.
Along with other topics related to environmental protection, the problem of corona audible noise from overhead transmission lines has recently become a subject of high interest. In this review paper, we analyze corona as the main source of audible noise on high voltage overhead transmission lines. We give the description of the problem, present state-of-the-art investigations and solutions used worldwide, and discuss them as a starting point for further research - in particular, with the goal to establish a clear methodology for solving, as well as preventing, this problem in the Republic of Serbia and beyond.